Jiaoxu Mei

Dr. Jiaoxu Mei


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
GMGu Mingsi
Gu Mingsi
JCJiajin Chen
Jiajin Chen
YZYiping Zhang
Yiping Zhang
TTTu Tan
Tu Tan
WGWang Guishi
Wang Guishi
JMJiaoxu Mei
Jiaoxu Mei
We designed a tunable diode laser absorption spectroscopy (TDLAS) sensor for the online monitoring of CO2 and H2O concentrations. It comprised a small self-design multi-pass cell, home-made laser drive circuits, and a data acquisition circuit. The optical and electrical parts and the gas circuit were integrated into a portable carrying case (height = 134 mm, length = 388 mm, and width = 290 mm). A TDLAS drive module (size: 90 mm × 45 mm) was designed to realize the function of laser current and temperature control with a temperature control accuracy of ±1.4 mK and a current control accuracy of ±0.5 μA, and signal acquisition and demodulation. The weight and power consumption of the TDLAS system were only 5 kg and 10 W, respectively. Distributed feedback lasers (2004 nm and 1392 nm) were employed to target CO2 and H2O absorption lines, respectively. According to Allan analysis, the detection limits of CO2 and H2O were 0.13 ppm and 3.7 ppm at an average time of 18 s and 35 s, respectively. The system response time was approximately 10 s. Sensor performance was verified by measuring atmospheric CO2 and H2O concentrations for 240 h. Experimental results were compared with those obtained using a commercial instrument LI-7500, which uses non-dispersive infrared technology. Measurements of the developed gas analyzer were in good agreement with those of the commercial instrument, and its accuracy was comparable. Therefore, the TDLAS sensor has strong application prospects in atmospheric CO2 and H2O concentration detection and ecological soil flux monitoring.

17 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
XTXing Tian
Xing Tian
YCYuan Cao
Yuan Cao
JCJiajin Chen
Jiajin Chen
KLKun Liu
Kun Liu
WGWang Guishi
Wang Guishi
XGXiaoming Gao
Xiaoming Gao
A sensitive dual-gas sensor for the detection of CH4 and C2H6 is demonstrated. Two tunable semiconductor lasers operating at 1.653 μm (for CH4 monitoring) and 1.684 μm (for C2H6) were used as the light source for spectroscopic measurements of CH4 and C2H6. Long-path absorption in a home-made compact dense-pattern multipass cell (Leff = 29.37 m) was employed, combined with wavelength modulation and second harmonic detection. Simultaneous detection of CH4 and C2H6 was achieved by separated wavelength modulations of the two lasers. Modulation frequencies and amplitudes were optimized for sensitivity detection of CH4 and C2H6 simultaneously. The dual-gas sensor exhibits 1σ detection limits of 1.5 ppbv for CH4 in 140 s averaging time and 100 ppbv for C2H6 in 200 s.

30 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
KWKunyang Wang
Kunyang Wang
LSLigang Shao
Ligang Shao
JCJiajin Chen
Jiajin Chen
WGWang Guishi
Wang Guishi
KLKun Liu
Kun Liu
XGXiaoming Gao
Xiaoming Gao
In this article, a compact dual-laser sensor based on an off-axis integrated-cavity output spectroscopy and time-division multiplexing method is reported. A complete dual-channel optical structure is developed and integrated on an optical cavity, which allows two distributed feedback (DFB) lasers operating at wavelengths of 1603 nm and 1651 nm to measure the concentration of CO2 and CH4, simultaneously. Performances of the dual-laser sensor are experimentally evaluated by using standard air (with a mixture of CO2 and CH4). The limit of detection (LoD) is 0.271 ppm and 1.743 ppb at a 20 s for CO2 and CH4, respectively, and the noise equivalent absorption sensitivities are 2.68 × 10−10 cm−1 Hz−1/2 and 3.88 × 10−10 cm−1 Hz−1/2, respectively. Together with a commercial instrument, the dual-laser sensor is used to measure CO2 and CH4 concentration over 120 h and verify the regular operation of the sensor for the detection of ambient air. Furthermore, a first-order exponential moving average algorithm is implemented as an effective digital filtering method to estimate the gas concentration.

16 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LSLigang Shao
Ligang Shao
JMJiaoxu Mei
Jiaoxu Mei
JCJiajin Chen
Jiajin Chen
TTTu Tan
Tu Tan
WGWang Guishi
Wang Guishi
XGXiaoming Gao
Xiaoming Gao
Previous research revealed that isotopes 13C and 18O of exhaled CO2 have the potential link with Helicobacter pylori; however, the 17O isotope has received very little attention. We developed a sensitive spectroscopic sensor for simultaneous δ13C, δ18O, and δ17O analysis of human breath CO2 based on mid-infrared laser direct absorption spectroscopy with an interband cascade laser (ICL) at 4.33 μm. There was a gas cell with a small volume of less than 5 mL, and the pressure in the gas cell was precisely controlled with a standard deviation of 0.0035 Torr. Moreover, real-time breath sampling and batch operation were achieved in gas inlets. The theoretical drifts for δ13C, δ18O, and δ17O measurement caused by temperature were minimized to 0.017‰, 0.024‰, and 0.021‰, respectively, thanks to the precise temperature control with a standard deviation of 0.0013 °C. After absolute temperature correction, the error between the system responded δ-value and the reference is less than 0.3‰. According to Allan variance analysis, the system precisions for δ13C, δ18O, and δ17O were 0.12‰, 0.18‰, and 0.47‰, respectively, at 1 s integration time, which were close to the real-time measurement errors of six repeated exhalations.

1 January 2022 in Acta Physica Sinica
Verified
Journal Article
Closed access
PDF file
FJFeng-Ming Jia
Feng-Ming Jia
JMJiaoxu Mei
Jiaoxu Mei
RWRui-Feng Wang
Rui-Feng Wang
GCGang Cheng
Gang Cheng
KLKun Liu
Kun Liu
XGXiao-Ming Gao
Xiao-Ming Gao
法拉第磁旋转光谱技术因其高灵敏度,零背景噪声以及能有效避免抗磁性物质干扰的特性被应用于各类顺磁性痕量气体的探测中。目前大部分法拉第磁旋转光谱技术采用交流线圈构造电磁场,存在能耗高、发热多等问题。为此,开展了基于组合环形永磁体的空间磁场分布建模仿真研究,意在建立轴向分布的磁场,为法拉第磁旋转光谱测量提供基于永磁体的沿光轴方向的匀强磁场。仿真采用有限元网格剖分的方法,基于麦克斯韦方程组,开展组合磁环的磁场分布仿真研究,并通过实验测量实际钕铁硼永磁体磁环阵列磁场分布,证明了建立物理模型的可靠性。在此基础上提出了对永磁体磁环阵列的3种优化方案——单理想值优化、多理想值优化和梯度优化方案,来构造中心轴线磁感应强度分布均匀的匀强磁场。最后通过引入磁场均匀度,计算评估并分析比较了不同优化方案的优化效果,为研发基于永磁体的法拉第磁旋转光谱设备提供参考。