When an existing photovoltaic (PV) system is upgraded to a residential PV/battery system, the single-phase PV inverter under both input conditions of battery and PV should be properly controlled to restrain the input current ripple and grid-current harmonics. To do this, equivalent circuits of PV array and Li-ion battery pack are first constructed and respectively analyzed. The analysis results show that the input current under the battery pack may contain serious ripple component due to the low internal impedance of the battery pack, which cannot suppress the ripple current caused by the inherent power coupling problem of the grid-connected single-phase inverter. Then, based on the small signal model of the boost dc-dc convertor, a novel active control method is proposed for mitigating the input current ripple, which adopts double-channel current feedbacks including an additional ripple current feedback channel and the normal one. To provide the feedback signal, a third-order general integrator is introduced to extract the current ripple. Besides, a proportional-resonant controller is used to restrain the grid-current harmonics. Finally, the control parameters are obtained using MATLAB toolbox, and the proposed control strategies are validated by the experimental results on a 5 kW prototype.
24 July 2018 in IEEE Transactions on Power Electronics
The Highly Efficient and Reliable Inverter Concept (HERIC) inverter is a cost-effective topology, which has low leakage currents and a relatively high efficiency. Thus, it is very suitable for transformerless PV system. However, with the reported modulation methods, it is difficult to simultaneously maintain high efficiency, good power quality, and reactive power injection of HERIC inverter. In this paper, a hybrid unipolar pulse width modulation (UP-PWM) scheme is thus proposed to achieve those performances. The hybrid scheme adopts the conventional UP-PWM in the case of generating the positive power. When generating the negative power, a modulation scheme, which only requires the operation of freewheeling switches, is specifically proposed. Additionally, in the region of the output voltage and current zero-crossing points (ZCP), an UP-PWM with modified dead time is introduced. In order to validate the effectiveness of the proposed scheme, simulations and experiments are performed on a 4-kW HERIC prototype with a 20-kHz switching frequency. The results demonstrate that the proposed hybrid UP-PWM method achieves a better performance in terms of reactive power injection than the conventional UP-PWM scheme, and a higher efficiency than the UP-PWM with dead time. In addition, the proposed UP-PWM scheme also enables a better power quality.
Arc fault diagnosis is necessary for the safety and efficiency of PV stations. This study proposed an arc fault diagnosis algorithm formed by combining variational mode decomposition (VMD), improved multi-scale fuzzy entropy (IMFE), and support vector machine (SVM). This method first uses VMD to decompose the current into intrinsic mode functions (IMFs) in the time-frequency domain, then calculates the IMFE according to the IMFs associated with the arc fault. Finally, it uses SVM to detect arc faults according to IMFEs. Arc fault data gathered from a PV arc generation experiment platform are used to validate the proposed method. The results indicated the proposed method can classify arc fault data and normal data effectively.
DC series arc fault detection is essential for improving the productivity of photovoltaic (PV) stations. The DC series arc fault also poses severe fire hazards to the solar equipment and surrounding building. DC series arc faults must be detected early to provide reliable and safe power delivery while preventing fire hazards. However, it is challenging to detect DC series arc faults using conventional overcurrent and current differential methods because these faults produce only minor current variations. Furthermore, it is hard to define their characteristics for detection due to the randomness of DC arc faults and other arc-like transients. This paper focuses on investigating a novel method to extract arc characteristics for reliably detecting DC series arc faults in PV systems. This methodology first uses an adaptive local mean decomposition (ALMD) algorithm to decompose the current samples into production functions (PFs) representing information from different frequency bands, then selects the PFs that best characterize the arc fault, and then calculates its multiscale fuzzy entropies (MFEs). Eventually, MFE values are inputted to the trained SVM algorithm to identify the series arc fault accurately. Furthermore, the proposed technique is compared to the logistic regression algorithm and naive Bayes algorithm in terms of several metrics assessing algorithms’ validity for detecting arc faults in PV systems. Arc fault data acquired from a PV arc-generating experiment platform are utilized to authenticate the effectiveness and feasibility of the proposed method. The experimental results indicated that the proposed technique could efficiently classify the arc fault data and normal data and detect the DC series arc faults in less than 1 ms with an accuracy rate of 98.75%.
Droop schemes are usually applied to the control of distributed generators (DGs) in microgrids (MGs) to realize proportional power sharing. The objective might, however, not suit MGs well for economic reasons. Addressing that issue, this paper proposes an alternative droop scheme for reducing the total active generation costs (TAGC). Optimal economic operation, DGs’ capacity limitations and system stability are fully considered basing on DGs’ generation costs. The proposed scheme utilizes the frequency as a carrier to realize the decentralized economic operation of MGs without communication links. Moreover, a fitting method is applied to balance DGs’ synchronous operation and economy. The effectiveness and performance of the proposed scheme are verified through simulations and experiments.