Single-walled carbon nanotubes (SWCNTs) have an advantage in printing thin film transistors (TFTs) due to their high carrier mobility, excellent chemical stability, mechanical flexibility, and compatibility with solution-based processing. Thus, the printed SWCNT-based TFTs (pSWCNT-TFTs) showed significant technological potential such as integrated circuits, conformable sensors, and display backplanes. However, the long-term environmental stability of the pSWCNT-TFTs hinders their commercialization. Thus, to extend the stability of the pSWCNT-TFTs, such devices should be passivated with low water and oxygen permeability. Herein, we introduced the silicon nitride (SiNx) passivation method on the pSWCNT-TFTs via a combination of roll-to-roll (R2R) gravure and the roll-to-roll plasma-enhanced vapor deposition (R2R-PECVD) process at low temperature (45 °C). We found that SiNx-passivated pSWCNT-TFTs showed ± 0.50 V of threshold voltage change at room temperature for 3 days and ±1.2 V of threshold voltage change for 3 h through a Temperature Humidity Test (85/85 test: Humidity 85%/Temperature 85 °C) for both p-type and n-type pSWCNT-TFTs. In addition, we found that the SiNx-passivated p-type and n-type pSWCNT-TFT-based CMOS-like ring oscillator, or 1-bit code generator, operated well after the 85/85 test for 24 h.
The roll-to-roll (R2R) gravure process has the potential for manufacturing single-wall carbon nanotubes (SWCNT)-based thin film transistor (TFT) arrays on a flexible plastic substrate. A significant hurdle toward the commercialization of the R2R-printed SWCNT-TFT array is the lack of a suitable, simple, and rapid method for measuring the uniformity of printed products. We developed a probing instrument for characterizing R2R gravure printed TFT, named PICR2R-TFT, for rapidly characterizing R2R-printed SWCNT-TFT array that can present a geographical distribution profile to pinpoint the failed devices in an SWCNT-TFT array. Using the newly developed PICR2R-TFT instrument, the current–voltage characteristics of the fabricated SWCNT-TFT devices could be correlated to various R2R-printing process parameters, such as channel length, roll printing length, and printing speed. Thus, by introducing a characterization tool that is reliable and fast, one can quickly optimize the R2R gravure printing conditions to enhance product uniformity, thereby maximizing the yield of printed SWCNT-TFT arrays.
Rapid, accurate, and scalable ion sensing technologies are highly desirable for future flexible healthcare and lab-on-a-chip applications. Here, we present a fully roll-to-roll (R2R) gravure-printed single-walled carbon nanotube complementary ring oscillator (SWCNT-cRO)-based microfluidic ion sensing platform fabricated on a flexible substrate. The proposed platform combines scalable printed complementary electronics with frequency-based ion sensing via electrostatically induced top-gating in aqueous microfluidic environments. The fabricated SWCNT-cRO devices exhibited stable oscillation characteristics, with a high device yield (>80%) and continuous manufacturing capability at a web speed of 5.4 m/min. Printable ethanolamine/zirconium acetylacetonate-based n-doping technology enabled complementary SWCNT transistor operation, while multilayer CYTOP/FG-3650 encapsulation ensured stable electrical operation under ionic aqueous conditions. After integration into a polydimethylsiloxane-based microfluidic channel, the oscillation frequency of the SWCNT-cRO was systematically modulated by Na+ concentration and pH. The sensing mechanism was based on electrostatically induced carrier modulation in n-type SWCNT transistors, resulting in variations in propagation delay and corresponding shifts in oscillation frequency. Compared with conventional ion-sensitive transistor platforms, the proposed approach offers scalable manufacturing, non-contact ion sensing, elimination of external reference electrodes, and direct compatibility with digital frequency-signal processing systems. This work establishes a promising strategy for future low-cost, disposable, and flexible microfluidic sensing platforms for wearable healthcare and lab-on-a-chip applications, ion sensing, and thin-film transistors.