David Beck

Mr. David Beck

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
DBDavid Beck
David Beck
PTPaul-Uwe P.U. Thamsen
Paul-Uwe P.U. Thamsen
Especially in the field of sewage pumps, the design of radial impellers focuses not only on maximum efficiency but also on functionality in terms of susceptibility to clogging by fibrous media. In general, the efficiency of sewage impellers is significantly lower than that of clear water impellers. These sewage impellers are designed with a low number of blades to ensure that fibrous media can be pumped. This paper describes the methodology of an optimisation for a sewage impeller. The optimisation is carried out on a semi-open two-channel impeller as an example. Therefore, a new impeller is designed for a given volute casing. Based on a basic design for given boundary conditions, the impeller is verified by means of numerical simulation. The manufactured impeller is then tested on the test rig to verify the simulation. With regard to the optical investigations, the clogging behaviour of the impeller is specifically improved over three different modifications in order to finally present an impeller with good efficiency and a low clogging tendency.

1 January 2023
Verified
Conference Paper
Open access
PDF file
FBFlorian Brokhausen
Florian Brokhausen
EHErik Herfurth
Erik Herfurth
DBDavid Beck
David Beck
PTPaul-Uwe P.U. Thamsen
Paul-Uwe P.U. Thamsen
The development of pumps for applications in wastewater systems is a complex and extensive task. In this setting, a pump needs to convey a multitude of different contaminants while maintaining functionality and, ideally, efficiency. Studies have shown that the main culprit for clogging in wastewater pumps are wipes made from long, fibrous materials. Therefore, a major insight into a pumps suitability for wastewater application is its susceptibility to clogging with these materials. At Technische Universität Berlin, Chair of Fluid System Dynamics, we operate a test stand dedicated to analyzing the behavior of pumps under artificial wastewater conditions and evaluate their susceptibility to clogging. The artificial wastewater is composed of varying degrees of fibrous wipes in water, called contamination classes. During multiple long-time functional performance tests with varying degrees of contamination and variations in the operation point, some 50 different pump setups have been tested. For each of these tests, the main output is the recording of the main operational parameters, i.e., electrical power, head, flow, and efficiency. Further, the weight of the contaminants being introduced to the test medium as well as the weight of contaminants being stuck in the pump at the end of the test are recorded. In this paper, these extensive tests are leveraged to draw conclusions regarding the behavior of different pump setups in wastewater operation. While previous studies have proven already that, e.g., ball passage and impeller type do not unequivocably influence a pumps suitability for wastewater application, this extensive evaluation goes beyond anecdotal evidence to show there actually are some common trends to be observed. For this investigation, correlations of the different meta-parameters, e.g., impeller diameter, operation point or ball passage, as well as time-resolved peculiarities are calculated via Spearman rank-order to showcase commonalities. In particular, four different characteristic patterns are leveraged to break down time-resolved behavior, namely, periods of high fluctuation, positive and negative monotonicity, as well as jumps in the signals. These patterns are quantified and subsequently correlated with the different meta-parameters of the pump setups. In an additional analysis, the different signal traces of tests are computationally compared with the technique of dynamic time warping. This can be leveraged to analyze (dis-)similarities in the full-length records of signal traces. The preliminary results show that at least over all test runs, including the multiple operation points and contamination classes, there are no explicit clusters to be observed when investigating the entire length of the signal traces. This supports the assumption that all pumps, be it with similar dimensions or impeller types, have individual characteristic behavior in wastewater applications, signifying the need for further disaggregation of time-resolved patterns. Therefore, in the full version of this paper, there will be a structured and elaborate analysis of the aforementioned characteristic patterns with quantifications of their correlations to several meta-parameters. The assumption to investigate is, that even if pumps behave very differently over the entire hour of testing, there are common time-related patterns, which do correlate with the meta-parameters of the pumps to some degree.

13 March 2024 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
DBDavid Beck
David Beck
PTPaul-Uwe P.U. Thamsen
Paul-Uwe P.U. Thamsen
Wastewater pumps are increasingly clogged by solids containing fibers. Closed 2-channel impellers in particular are often highly susceptible to clogging due to their geometric properties, even though they have among the highest clear water efficiencies compared to other wastewater impellers. With the help of a clogging test rig, a prototype that can accommodate different closed 2-channel geometries, the use of three-dimensional simulation as well as an optical access for high-speed recordings, a methodology is to be created, whereby this impeller type can be effectively optimized. In this paper, the first impeller modification is calculated, manufactured, simulated, and tested with this methodology.

1 January 2023
Verified
Conference Paper
Open access
PDF file
DBDavid Beck
David Beck
MSMatthias Steffen
Matthias Steffen
PTPaul-Uwe P.U. Thamsen
Paul-Uwe P.U. Thamsen
Wastewater pumps are facing ever-increasing challenges from solids. These solids cause a significant number of malfunctions, which can manifest itself in changed hydraulic performance, altered energy consumption, and system downtime due to clogging within the pump. A particular proportion of solids being responsible for disturbances in the wastewater system is represented by tear-resistant fibrous materials, e.g. wet wipes. The increased concentration of these wet wipes in the wastewater system and the resulting clogging provides the need to assess the functionality of wastewater pumps. At the new test rig for functional tests at the Technische Universität Berlin at the Chair of Fluid System Dynamics, more than 50 different wastewater pumps have been tested so far for their susceptibility to clogging. Previous assessments for pumps refer to the efficiency of the aggregates, for example in ISO 9906. However, since functionality does not correlate with efficiency, the test rig specifically examines functionality in different approaches. The two main test procedures that are used to evaluate functionality differ in their procedure and duration: the functional performance test involves the one-time pumping of a defined quantity of artificial wastewater, while the long-time functional performance test involves the continuous pumping of a defined quantity of artificial wastewater for 60 minutes. By means of these two test procedures, different aspects of the functionality of the wastewater pumps can be investigated. It has already been found by means of both test procedures that neither ball passage nor impeller type have a significant influence on the functionality of sewage pumps. To obtain more specific insights into the interaction between the impeller and wet wipes, an optical access is additionally installed on the test rig, with which targeted observations of the individual pumps can be carried out by means of an endoscope and a high-speed camera. This paper deals with the experience gained in measuring the functionality of wastewater pumps on this new test rig for functional tests by taking a holistic view of the pumps measured to date. The different experiences of the functional performance test, the long-time functional performance test and findings from optical examinations are discussed. The functionality of the aggregates is evaluated and compared with the aid of both test procedures. The behavior of the pumps is explained by means of a limit value for the degree of functional performance as well as the degree of long-time functional performance, and the composition of the individual partial results is discussed. Since the pumps tested so far vary in their performance class as well as in their suction- and pressure-side connection dimensions, the clogging behavior of these different pump sizes on the test rig is also analyzed within this paper. This is carried out to show that the clogging behavior of wastewater pumps can be evaluated on this test rig, irrespective of their performance class.

16 July 2021
Verified
Preprint
Open access
SWSebastian Wulff
Sebastian Wulff
DBDavid Beck
David Beck
MRMorris Reich
Morris Reich
JWJean Pierre Worringer
Jean Pierre Worringer
PTPaul-Uwe P.U. Thamsen
Paul-Uwe P.U. Thamsen
Modern submersible pumps are high performance aggregates for long-term operation, which find application in open pit mining. Dewatering of groundwater to run an open pit mine with various conditions for submersible pumps often leads to short-term performance based on different circumstances in the well as well as in the general operation. These result in high maintenance and energy

TRTobias Rinnert
Tobias Rinnert
TNTim Nitzsche
Tim Nitzsche
DBDavid Beck
David Beck
FBFlorian Brokhausen
Florian Brokhausen
PTPaul-Uwe P.U. Thamsen
Paul-Uwe P.U. Thamsen
This paper presents methods and results on optimizing the functionality of pressurized sewerage systems, specifically wastewater pumping stations. A holistic approach is introduced to address major issues in wastewater transport such as sedimentation in suction chambers and fiber-induced issues in wastewater pumps, as well as their effects and detection. A conceptual suction chamber is scaled using hydraulic similarity and is experimentally investigated regarding its susceptibility to sedimentation. Optimization of inlets and manifolds, pumps, and sloped walls contribute to minimizing sedimentation. In terms of wastewater pumps, a semi-open two-channel wastewater impeller is optimized for its efficiency via response surface optimization. The subsequent optimization for functionality showcases the nexus of the two characteristics by means of cut-back and thickened leading edges, which significantly reduce the susceptibility to clogging. Another important consideration in wastewater pump design is the back shroud cavity. Through iterative experiments with different housing recess configurations, the back shroud cavity is optimized to minimize fiber entry and protect the mechanical seal. Lastly, the demonstration of the effects of clogging in the form of transient instationarities in the torque of a wastewater pump underline the importance of optimizing wastewater pumps for their functionality and low susceptibility to clogging.