Tobias Rinnert

Mr. Tobias Rinnert

Fluid System Dynamics, Technische Universität Berlin, Berlin, Germany
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025
Verified
Conference Paper
Open access
PDF file
TRTobias Rinnert
Tobias Rinnert
PTPaul Uwe Thamsen
Paul Uwe Thamsen
Wastewater pumps form the backbone of urban wastewater systems. As part of the critical infrastructure, their blockage-free and therefore reliable operation is of utmost importance. However, in practice, the clogging of wastewater pumps by fibrous material poses a massive problem for operators when affected pumps need to be taken out of operation in order to remove the blockage. Depending on the design of the pump impeller and pump housing as well as other design features, there are several areas within wastewater pumps where the entry of fibers and other solids poses a risk of clogging. One of these critical locations is the back shroud cavity between the impeller back shroud and the rear casing wall. The mechanical seal is often located in this area and can be affected negatively by the buildup of fibers and solids. At the Chair of Fluid System Dynamics of Technische Universität Berlin, multiple test rigs are operated to evaluate and optimize the functionality of wastewater pumps, through which artificial wastewater is pumped in a circuit using tear-resistant dusters mixed with fresh water. The test rig used in this investigation is a model test rig of a wastewater pumping station, which provides insights into various areas that are at risk of clogging in wastewater pumps. Based on high-speed videos of the interactions between fibers and pump components made visible by an optical access, the underlying clogging and flow mechanisms can be understood and appropriate design measures can be taken to prevent clogging in wastewater pumps. These measures are then implemented and validated on this test rig. This paper investigates the influence of the axial gap width between the impeller back shroud and the rear casing wall on the clogging behavior and the underlying clogging mechanisms. The experiments presented are carried out on a dry-installed wastewater pump with a semi-open two-channel impeller. The impeller back shroud is equipped with multiple threaded holes, that are used in this investigation to mount flat disk-shaped back shroud geometries of different thicknesses. The back shroud cavity can be observed through an acrylic glass window. This optical access allows relevant flow and clogging processes to be observed and documented using a high-speed camera. The axial gap widths investigated are 1 mm, 2 mm, 3 mm, 4 mm, and 5 mm. Three operating points are examined for each gap width configuration, one of which is at part load, one at the best efficiency point, and one at overload. The clogging behavior of the respective configurations is evaluated on the basis of the fiber dry mass permanently accumulated in defined areas after a pumping test duration of 60 min.

26 March 2026 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
TRTobias Rinnert
Tobias Rinnert
PTPaul Uwe Thamsen
Paul Uwe Thamsen
In this paper, the influence of different back vanes (BVs) and back channels (BCs) on fiber entry into the back shroud cavity is experimentally investigated. Vane and channel contours correspond to backward curved blades of a semi-open two-channel impeller. The configurations feature varying axial gap widths between back shroud and rear housing wall. Vane height and channel depth are also changed throughout the tests. Vane and channel width as well as number are constant. The axial gap width between rear housing wall and back vane top or channel ground is constant as well. For each configuration, the operating points part load, best efficiency point, and overload are examined. Tested configurations are compared to unmodified reference configurations regarding fiber dry mass accumulated in a defined area within the back shroud cavity after a test duration of 60 min. The experiments demonstrate that selected back vane configurations reduce fiber entry by up to 100%, causing minor decreases in operating point-averaged overall efficiency of 0.8% and less. The back channel configuration investigated at minimum axial gap width eliminates the minor fiber entry of the reference configuration, decreasing operating point-averaged overall efficiency by 0.9%. In contrast, mean fiber entry is significantly increased by the back channels at larger gap widths by up to 0.679 g. Except for one back channel configuration with minor fiber entry of up to 0.046 g, none of the presented back vane or back channel configurations shows fiber entry at part load.

15 July 2024
Verified
Conference Paper
Closed access
TRTobias Rinnert
Tobias Rinnert
DBDavid Beck
David Beck
PTPaul Uwe Thamsen
Paul Uwe Thamsen
Previous investigations have already shown the delay of flow separation at critical angles of attack as an effect of tubercles on the flow around airfoils both, numerically and experimentally. However, concerning axial pump impellers, the knowledge about the influence of tubercle modification along the leading edge is not yet sufficient. Therefore, the aim of this investigation is to understand the influence of a sinusoidal tubercle leading edge geometry on the operating behavior as well as the cavitation behavior of an axial pump using numerical and experimental methods. For this purpose, an unmodified reference impeller with a Gö11K profile is designed, which serves as the basis for the impeller modified with tubercles. Using a steady-state simulation, the characteristics of each impeller are investigated. The operating behavior of both impellers is then investigated on a test rig according to EN ISO 9906. The experimental investigations lead to the finding that the presented tubercle modification causes a reduction of the head at part load and an increase at overload. Furthermore, the experiments show that the tubercle modification increases maximum efficiency. The experimental investigation of the cavitation behavior of both impellers shows that the introduced tubercle modification generally leads to the onset of cavitation-induced head drop at significantly lower NPSH values, thus improving the cavitation behavior.

TRTobias Rinnert
Tobias Rinnert
TNTim Nitzsche
Tim Nitzsche
DBDavid Beck
David Beck
FBFlorian Brokhausen
Florian Brokhausen
PTPaul-Uwe P.U. Thamsen
Paul-Uwe P.U. Thamsen
This paper presents methods and results on optimizing the functionality of pressurized sewerage systems, specifically wastewater pumping stations. A holistic approach is introduced to address major issues in wastewater transport such as sedimentation in suction chambers and fiber-induced issues in wastewater pumps, as well as their effects and detection. A conceptual suction chamber is scaled using hydraulic similarity and is experimentally investigated regarding its susceptibility to sedimentation. Optimization of inlets and manifolds, pumps, and sloped walls contribute to minimizing sedimentation. In terms of wastewater pumps, a semi-open two-channel wastewater impeller is optimized for its efficiency via response surface optimization. The subsequent optimization for functionality showcases the nexus of the two characteristics by means of cut-back and thickened leading edges, which significantly reduce the susceptibility to clogging. Another important consideration in wastewater pump design is the back shroud cavity. Through iterative experiments with different housing recess configurations, the back shroud cavity is optimized to minimize fiber entry and protect the mechanical seal. Lastly, the demonstration of the effects of clogging in the form of transient instationarities in the torque of a wastewater pump underline the importance of optimizing wastewater pumps for their functionality and low susceptibility to clogging.

27 July 2025
Verified
Conference Paper
Closed access
TRTobias Rinnert
Tobias Rinnert
PTPaul Uwe Thamsen
Paul Uwe Thamsen
In this paper, the influence of different back vanes and back channels on fiber entry into the back shroud cavity is investigated. Vane and channel contours correspond to backward curved blades of a semi-open two-channel impeller. The configurations feature varying axial gap widths between back shroud and rear housing wall. Vane height and channel depth are also changed throughout the tests. Vane and channel width as well as number are constant. The axial gap width between rear housing wall and back vane top or channel ground is constant as well. Three operating points are examined for each configuration, one at part load, one at best efficiency point and one at overload. Tested configurations are evaluated regarding fiber dry mass accumulated in a defined area within the back shroud cavity after a test duration of 60 min. The experiments show that the back vane configurations can significantly reduce or eliminate fiber entry at best efficiency point and especially at overload operation. The back channel configuration investigated at minimum axial gap width and maximum channel depth eliminates fiber entry at best efficiency point and overload operation, whereas fiber entry is generally increased by the back channels at moderate and large gap widths at these operating points. None of the back vane and back channel configurations show any significant fiber entry at part load.

26 August 2025
Verified
Conference Paper
Closed access
TRTobias Rinnert
Tobias Rinnert
PTPaul Uwe Thamsen
Paul Uwe Thamsen