Marco Stefanati

Dr. Marco Stefanati

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2024 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
MSMarco Stefanati
Marco Stefanati
ACAnna Corti
Anna Corti
VCValentina Corino
Valentina Corino
MBMartin Bennett
Martin Bennett
ZTZhongzhao Teng
Zhongzhao Teng
JMJose Felix Rodriguez Matas
Jose Felix Rodriguez Matas

15 July 2025 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
VLVittorio Lissoni
Vittorio Lissoni
GLGiulia Luraghi
Giulia Luraghi
MSMarco Stefanati
Marco Stefanati
JMJose Felix Rodriguez Matas
Jose Felix Rodriguez Matas
FMFrancesco Migliavacca
Francesco Migliavacca
In recent years, computational simulations have emerged as valuable tools for the evaluation of atherosclerosis progression in coronary anatomies, although only a few studies have utilized more realistic Fluid-Structure Interaction (FSI) simulations. This work aims to compare the results of Computational Fluid Dynamics (CFD), Structural Finite Element Analysis (structural FEA) and FSI simulations in order to assess differences in plaque progression indices estimation. We performed structural FEA, CFD and FSI on five patient-specific epicardial coronary anatomies using the commercial software LS-Dyna. To account for the vessel pre-stress, the zero-pressure configuration was calculated for each anatomy with an inverse elastostatic algorithm. CFD, structural FEA and FSI simulations were performed applying boundary conditions based on physiological values. The comparison between structural FEA and FSI showed similar stress distribution and vessel expansions, with differences found only in the distal parts of the coronaries, where pressure reduction due to pressure loss affects the vessel walls. The elastic walls of the coronaries impact blood flow, resulting in a more disturbed flow. However, time averaged wall shear stress (TAWSS) and oscillatory shear index (OSI) distributions are similar across each coronary between CFD and FSI; TAWSS is slightly higher in CFD while OSI peaks are higher in FSI. In conclusion, given the significantly higher computational costs of FSI, we believe that CFD and structural FEA offer a more practical and cost-effective approach, providing results comparable to those of FSI, making them preferable options.

5 December 2024 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
ACAnna Corti
Anna Corti
MSMarco Stefanati
Marco Stefanati
MLMatteo Leccardi
Matteo Leccardi
OFOvidio De Filippo
Ovidio De Filippo
ADAlessandro Depaoli
Alessandro Depaoli
GDGabriele Dubini
Gabriele Dubini
Nowadays, vulnerable coronary plaque detection from coronary computed tomography angiography (CCTA) is suboptimal, although being crucial for preventing major adverse cardiac events. Moreover, despite the suggestion of various vulnerability biomarkers, encompassing image and biomechanical factors, accurate patient stratification remains elusive, and a comprehensive approach integrating multiple markers is lacking. To this aim, this study introduces an innovative approach for assessing vulnerable coronary arteries and patients by integrating radiomics and biomechanical markers through machine learning methods. The study included 40 patients (7 high-risk and 33 low-risk) who underwent both CCTA and coronary optical coherence tomography (OCT). The dataset comprised 49 arteries (with 167 plaques), 7 of which (with 28 plaques) identified as vulnerable by OCT. Following image preprocessing and segmentation, CCTA-based radiomic features were extracted and a finite element analysis was performed to compute the biomechanical features. A novel machine learning pipeline was implemented to stratify coronary arteries and patients. For each stratification task, three independent predictive models were developed: a radiomic, a biomechanical and a combined radiomic-biomechanical model. Both k-nearest neighbors (KNN) and decision tree (DT) classifiers were considered. The best radiomic model (KNN) detected all 7 vulnerable arteries and patients and was associated with a balanced accuracy of 0.86 (sensitivity=1, specificity=0.71) for the artery model and of 0.83 (sensitivity=1, specificity=0.67) for the patient model. The best biomechanical model (DT) detected 6 over 7 vulnerable arteries and patients and remarkably increased the specificity, resulting in a balanced accuracy of 0.89 (sensitivity=0.86, specificity=0.93) for the artery model and of 0.88 (sensitivity=0.86, specificity=0.91) for the patient model. Notably, the combined approach optimized the performance, with an increase in the balance accuracy up to 0.94 for the artery model and up to 0.92 for the patient model, being associated with sensitivity=1 and high specificity (0.88 and 0.85 for artery and patient models, respectively). This investigation highlights the promise of radio-mechanical coronary artery phenotyping for patient stratification. If confirmed from larger studies, our approach enables a more personalized management of the disease, with the early identification of high-risk individuals and the reduction of unnecessary interventions for low-risk individuals.

6 April 2023 in Mathematics
Verified
Journal Article
Open access
PDF file
Stephan GahimaStephan Gahima
Stephan Gahima
PDPedro Diez
Pedro Diez
MSMarco Stefanati
Marco Stefanati
JMJose Felix Rodriguez Matas
Jose Felix Rodriguez Matas
AGAlberto García
Alberto García
This manuscript presents a novel formulation for a linear elastic model of a heterogeneous arterial section undergoing uniform pressure in a quasi-static regime. The novelties are twofold. First, an elastic bed support on the external boundary (elastic bed boundary condition) replaces the classical Dirichlet boundary condition (i.e., blocking displacements at arbitrarily selected nodes) for elastic solids to ensure a solvable problem. In addition, this modeling approach can be used to effectively account for the effect of the surrounding material on the vessel. Secondly, to study many geometrical configurations corresponding to different patients, we devise an unfitted strategy based on the Immersed Boundary (IB) framework. It allows using the same (background) mesh for all possible configurations both to describe the geometrical features of the cross-section (using level sets) and to compute the solution of the mechanical problem. Results on coronary arterial sections from realistic segmented images demonstrate that the proposed unfitted IB-based approach provides results equivalent to the standard finite elements (FE) for the same number of active degrees of freedom with an average difference in the displacement field of less than 0.5%. However, the proposed methodology does not require the use of a different mesh for every configuration. Thus, it is paving the way for dimensionality reduction.

1 October 2019 in Journal of the Mechanics and Physics of Solids
Verified
Journal Article
Closed access
PDF file
MSMarco Stefanati
Marco Stefanati
CVChiara Villa
Chiara Villa
YTYvan Torrente
Yvan Torrente
JMJosé Félix Rodriguez Matas
José Félix Rodriguez Matas

1 February 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
MSMarco Stefanati
Marco Stefanati
YTYvan Torrente
Yvan Torrente
JMJosé Félix Rodriguez Matas
José Félix Rodriguez Matas