Cong Ma

Dr. Cong Ma

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
SWShaoxi Wang
Shaoxi Wang
XZxiafeng zhang
xiafeng zhang
CMCong Ma
Cong Ma
Sheng YanSheng Yan
Sheng Yan
David W. InglisDavid W. Inglis
David W. Inglis
Shilun FengShilun Feng
Shilun Feng
Microfluidics offer microenvironments for reagent delivery, handling, mixing, reaction, and detection, but often demand the affiliated equipment for liquid control for these functions. As a helpful tool, the capillary pressure control valve (CPCV) has become popular to avoid using affiliated equipment. Liquid can be handled in a controlled manner by using the bubble pressure effects. In this paper, we analyze and categorize the CPCVs via three determining parameters: surface tension, contact angle, and microchannel shape. Finally, a few application scenarios and impacts of CPCV are listed, which includes how CPVC simplify automation of microfluidic networks, work with other driving modes; make extensive use of microfluidics by open channel, and sampling and delivery with controlled manners. The authors hope this review will help the development and use of the CPCV in microfluidic fields in both research and industry.

12 April 2024 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Open access
CMCong Ma
Cong Ma
YXYan Xu
Yan Xu
HCHuilei Chen
Huilei Chen
Yue HuangYue Huang
Yue Huang
SWShanshan Wang
Shanshan Wang
YCYun-Xia Cao
Yun-Xia Cao
The use of bisphenol A (BPA) has been restricted due to its endocrine-disrupting effects. As a widely used alternative to BPA today, environmental levels of bisphenol Z (BPZ) continue to rise and accumulate in humans. Oocyte quality is critical for a successful pregnancy. Nevertheless, the toxic impacts of BPZ on the maturation of mammalian oocytes remain unexplored. Therefore, the impacts of BPZ and BPA on oocyte meiotic maturation were compared in an in vitro mouse oocyte culture model. Exposure to 150 μM of both BPZ and BPA disrupted the assembly of the meiotic spindle and the alignment of chromosomes, and BPZ exerted stronger toxicological effects than BPA. Furthermore, BPZ resulted in aberrant expression of F-actin, preventing the formation of the actin cap. Mechanistically, BPZ exposure disrupted the mitochondrial localization pattern, reduced mitochondrial membrane potential and ATP content, leading to impaired mitochondrial function. Further studies revealed that BPZ exposure resulted in oxidative stress and altered expression of genes associated with anti-oxidative stress. Moreover, BPZ induced severe DNA damage and triggered early apoptosis in oocytes, accompanied by impaired lysosomal function. Overall, the data in this study suggest that BPZ is not a safe alternative to BPA. BPZ can trigger early apoptosis by affecting mitochondrial function and causing oxidative stress and DNA damage in oocytes. These processes disrupt cytoskeletal assembly, arrest the cell cycle, and ultimately inhibit oocyte meiotic maturation.

5 May 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
CMCong Ma
Cong Ma
YSYimeng Sun
Yimeng Sun
HYH YH
H YH
ZGZehang Gao
Zehang Gao
YHYaru Huang
Yaru Huang
JZJianlong Zhao
Jianlong Zhao
We developed a microfluidic chip integrated with nucleic acid purification and droplet-based digital polymerase chain reaction (ddPCR) modules to realize a ‘sample-in, result-out’ infectious virus diagnosis. The whole process involved pulling magnetic beads through drops in an oil-enclosed environment. The purified nucleic acids were dispensed into microdroplets by a concentric-ring, oil–water-mixing, flow-focusing droplets generator driven under negative pressure conditions. Microdroplets were generated with good uniformity (CV = 5.8%), adjustable diameters (50–200 μm), and controllable flow rates (0–0.3 μL/s). Further verification was provided by quantitative detection of plasmids. We observed a linear correlation of R2 = 0.9998 in the concentration range from 10 to 105 copies/μL. Finally, this chip was applied to quantify the nucleic acid concentrations of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The measured nucleic acid recovery rate of 75 ± 8.8% and detection limit of 10 copies/μL proved its on-chip purification and accurate detection abilities. This chip can potentially be a valuable tool in point-of-care testing.

1 January 2021
Verified
Book Chapter
Closed access
QYQiang Yuan
Qiang Yuan
ZLZanqun Liu
Zanqun Liu
KZKeren Zheng
Keren Zheng
CMCong Ma
Cong Ma