The high penetration rate of distributed generations (DGs) makes the distribution network’s fault characteristics complex and variable, which limits the application of traditional current differential protection (CDP) in active distribution networks. According to the amplitude and phase characteristics analysis of positive-sequence current fault components (PSCFCs) in the active distribution network, a novel CDP method based on the adaptive phase angle compensation coefficient is proposed. The method improves the traditional CDP by introducing an adaptive phase angle compensation coefficient, which adaptively compensates the phase of PSCFCs on the DG side according to the phase difference and amplitude ratio of PSCFCs on both sides of the protected feeder. To effectively cope with the negative impact of unmeasurable load branches on protection reliability, the polarity information of the action impedance is used to construct an auxiliary criterion. The effectiveness of the proposed protection scheme is verified in the PSCAD/EMTDC. Compared with the traditional CDP, this scheme can meet the protection needs of active distribution networks under various fault scenarios with high sensitivity and reliability. The proposed method can withstand high fault resistance and large time synchronization errors, and it can still trip correctly under 150 Ω fault resistance or 4.6 ms time synchronization errors.
The incorrect operation of protective relays and circuit breakers will significantly compromise the safety and stability of power systems. To promptly detect the faults of the relay protection system and the circuit breakers in time and to ensure the operational reliability of these protective devices, this paper proposes a fault tracing method for a relay protection system–circuit breaker based on improved Random Forest. Firstly, an analysis is conducted to identify the causes of incorrect operation of the protective relay and the circuit breaker. The fault types and corresponding alarm messages for the relay protection system and the circuit breaker are categorized, and the alarm feature set is constructed. Then, the Random Forest is improved and trained to develop the fault tracking model. Finally, the operation evaluation process is developed to determine the incorrect operations of the protective relay and the circuit breaker, and the fault tracking model and fault tracking process are then employed to locate the faults of the relay protection system and the circuit breaker. The experimental results demonstrate the method’s capability to accurately track faults in the relay protection system and the circuit breaker, thereby assisting operation and maintenance personnel in troubleshooting and highlighting its promising practical potential.
Fuzzy and temporal reasoning can effectively improve the accuracy of fault diagnosis methods. However, there are challenges in practical applications, such as missing alarm messages, temporal reasoning with complex calculations, and complex modeling processes. Therefore, this study proposes an improved temporal fuzzy reasoning spiking neural P (ITFRSNP) system for power system fault diagnosis. First, the ITFRSNP system and its reasoning method are proposed to perform association reasoning between confidence degrees and temporal constraints. Second, a general fault diagnosis model and process are developed based on the ITFRSNP system to diagnose various faulty components and simplify the modeling process. In addition, a search method is provided for identifying suspected faulty components, considering the missing alarm message of the circuit breaker. Simulation results of fault cases demonstrate that the proposed method exhibits high accuracy and fault tolerance. It can precisely identify faulty components despite incorrect operations or inaccurate alarm messages of protective relays and circuit breakers. Moreover, the search method effectively narrows down the diagnostic scope without missing suspected faulty components in scenarios where alarms from boundary circuit breakers are missing, thereby enhancing the fault diagnosis efficiency. The fault diagnosis model features a straightforward structure and reasoning process with minimal computational complexity, making it suitable for real-time diagnosis of complex faults within power systems.
The high penetration of inverter-based distributed generations (IBDGs) leads to traditional distribution networks’ complex and variable fault characteristics. Traditional passive detection protection methods can hardly meet the stability and reliability requirements. To solve this problem, an injection harmonic current differential protection (IHCDP) scheme based on the idea of control-protection synergy is proposed in this paper. By analyzing the circuit structure, control strategy, low-voltage-ride-through characteristics of IBDGs, and short-circuit currents provided by IBDGs, an injection-control strategy of characteristic harmonic currents (CHCs) based on the d-axis and q-axis is proposed. According to the change of short-circuit currents provided by the IBDG, the amplitude of CHCs is adaptively corrected to strengthen the fault characteristics and ensure that the distribution network harmonic injection protocols are always satisfied. An IHCDP criterion based on the distortion rate of the negative-sequence component of CHCs is proposed by analyzing the fault characteristics of the CHCs after injection. To effectively eliminate the dead-zone problem during symmetrical short-circuit faults, the proposed IHCDP utilizes the distortion rate of A-phase CHCs. The feasibility of the proposed protection scheme is demonstrated by the theoretical analysis and simulation results in this paper.