We present a simulation-assisted methodology for the design of point or distributed fiber dosimeters exploiting the linear dependence of the infrared radiation-induced attenuation of a single-mode phosphosilicate optical fiber. We demonstrate by comparing Monte Carlo simulations and experiments at different irradiation facilities (X-rays, γ-rays, protons and atmospheric neutrons) that the sensitivity coefficient of this fiber is independent on the nature of particles and on dose rate, at least up to total ionizing doses in the order of 500 Gy. Our simulations allow us to simulate the dose deposited in the fiber core (and then the Radiation Induced Attenuation (RIA) levels) for the different classes of particles (photons, electrons, neutrons, protons and heavy ions) and for different energy ranges. From this data, and knowing the environments of targeted applications for the fiber optic dosimeters, we can discuss the different designs and achievable performance using this fiber. Examples are discussed with space applications, atmospheric balloon experiments and fusion-devoted facilities.
The device downscaling of electronic components has given rise to the need to consider specific failures in onboard airplane electronics. Single Event Effects (SEE) are a kind of failures that occur due to radiation in the atmosphere. For the purpose of ensuring onboard electronic reliability, there is a clear need for new tools to predict the SEE rate, at both avionic altitudes and at ground level. In this work, we develop a new tool: RAMSEES (Radiation Atmospheric Model for SEE Simulation), which simulates the atmospheric radiative environment induced by cosmic rays. This multiscale and multi-physics phenomenon is simulated using the Geant4 toolkit, allowing the creation of a database to characterize the radiation environment in the atmosphere as a function of altitude. We show the need to simulate very high-energy particles such as 100 TeV space protons, because they are the main contributor of radiation at avionic altitudes as well as at ground level. Our approach shows a good agreement with the experimental data, the standards, and other models, and it also points out some discrepancies, especially below 18 km of altitude. RAMSEES can be the basis of the estimation of the SEE rate from ground level to the stratosphere, at any given position and time.
13 November 2024 in Journal of Space Weather and Space Climate
A new model of the Martian surface radiative environment has been built: Atmospheric RAdiation Model for Ionizing spectra on martian Surface (ARAMIS). Based on Monte Carlo calculations, it offers high computational flexibility for surface flux spectra with several GEANT4 physics lists tested for different exposures and mission scenarios. ARAMIS performs Monte Carlo simulations independently of any exposure scenario to determine a surface response function that can then be convolved to any input spectrum, avoiding simulation repetition while maintaining results accuracy, using a parametric atmosphere geometry. In particular, the adopted approach enables secondary spectra to be discriminated by type and origin, in order to observe the impact of different primary flux components on the surface dose calculation. The ARAMIS model has been validated with experimental measurements from the RAD (Radiation Assessment Detector) instrument on board the Mars Science Laboratory (MSL) Curiosity rover, and benchmarked against other models in the literature. Built using version 11.1.0 of the GEometry ANd Tracking (GEANT4) toolbox and established models of Galactic Cosmic Ray (GCR) or Solar Particle Event (SEP) spectra, the surface neutron and photon spectra provided by ARAMIS show a better agreement than other models with high-energy experimental data, reducing model uncertainty for radiation protection calculations.
22 February 2024 in IEEE Transactions on Nuclear Science
This paper presents the PIX instrument based on a raspberry Pi and a MiniPIX device dedicated to make measurements of ionizing particles onboard stratospheric balloons. The hardware part and the software part of the PIX instrument are described. All the characteristics of the instrument are given in this paper. The three flight opportunities are also presented, with the associated measurements. The methodology to calculate fluxes based on measurements is explained. In particular, the calculation of response functions of protons, electrons, and photons by using Monte-Carlo simulations, the identification algorithm based on a neural network trained with simulated data, and the calculation of fluxes from count rates are described. Some measurements performed in different facilities are presented. A part of these experimental tracks have been used to challenge the neural network previously trained with simulated date, to check the robustness of the algorithm. Proton, electron, and photon fluxes are presented and compared to the MAIRE model.
7 March 2025 in IEEE Transactions on Nuclear Science
This work investigates the response of specially developed silicon p-i-n diodes with a long base as sensors to measure displacement damage dose (DDD) in silicon. Measurements of DDD are based on the forward voltage shift (ΔVF) of irradiated p-i-n diodes. In this work the p-i-n diodes were irradiated in the following radiation fields: i) 20 MeV electrons from a medical LINAC (linear accelerator); ii) 200 MeV, 150 MeV, 100 MeV protons at the Groningen proton therapy facility and; iii) 4.63 MeV and 15.3 MeV quasi-monoenergetic neutrons at the Czech Technical University, Prague. It was demonstrated that the calibration factor (α), that is the response of the p-i-n diode in terms of DDD obtained using 20 MeV electrons, can be used to predict the p-i-n diode response for protons and neutrons as mentioned above (within experimental error). However, the p-i-n diodes response related to 100 MeV protons has a 70% higher response than predicted that requires further investigation. Overall, the 20 MeV electrons from a medical LINAC were found to be suitable for p-i-n diodes calibration in terms of the non-ionizing energy losses (NIEL) and is widely available in contrast to 1 MeV electrons, fast neutrons and protons.
We present the study of the response of a Timepix2 detector (256 × 256 pixels, pixel pitch 55 µm) with a 500 µm thick silicon sensor in laboratory measurements with α sources, charged particle beams of relativistic ion fragments at the Super-Proton-Synchrotron at CERN and in short-ranged heavy ion beams at the Heavy Ion Facility of UCLouvain in Belgium: 22Ne, 53Cr and 103Rh of 238, 505 and 957 MeV, respectively. The Timepix2 detector was used in adaptive gain mode, and calibrated using previously developed methodology using protons with energies in the range from 500 keV to 2 MeV and α-particles of 5.5 MeV from 241Am source prior to the testing. In a laboratory experiment, the detector was irradiated with α-particle from a 239Pu241Am244Cm source. α-particles of higher energy (∼ 9 MeV) were obtained through a measurement of naturally occurring decays of radon and its daughters while the detector was left running in the laboratory for two weeks. In both cases, an energy resolution of 2% was achieved. In the stopped ion beam measurement, the proper ion energy determination was hindered by the per-pixel saturation of 3.2 MeV. Still, due to an increase of measured energy with increasing charge deposition, the different ion species were separable. In the last study, the dE/dX spectra were obtained in a mixed relativistic particle beam and used to evaluate the capability of determining the beam composition. The spectrum stripping technique using iterative Landau curve fitting was applied to the spectra allowing for ion charge determination up to Z = 13. The per-pixel saturation was mitigated by placing the detector at an angle of 70 degrees with respect to the sensor normal.