Sahar Abdalbary

Prof. Dr. Sahar Abdalbary

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2024 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
AAAhmad Alhaskawi
Ahmad Alhaskawi
HZHaiying Zhou
Haiying Zhou
YDYanzhao Dong
Yanzhao Dong
XZXiaodi Zou
Xiaodi Zou
SESohaib Hasan Abdullah Ezzi
Sohaib Hasan Abdullah Ezzi
HLHui Lu
Hui Lu

26 August 2023 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Closed access
JFJing Fu
Jing Fu
AAAHMAD ALHASKAWI
AHMAD ALHASKAWI
YDYanzhao Dong
Yanzhao Dong
FJFeilu Jin
Feilu Jin
JCJing Chen
Jing Chen
hui luhui lu
hui lu

1 February 2016 in Medicine
Verified
Journal Article
Open access
SASahar Abdalbary
Sahar Abdalbary
EEEhab A.A. Elshaarawy
Ehab A.A. Elshaarawy
BKBahaa E.A. Khalid
Bahaa E.A. Khalid
The deep transverse metatarsal ligament (DTML) connects the neighboring 2 metatarsal heads and is one of the stabilizers connecting the lateral sesamoid and second metatarsal head. In this study, we aimed to determine the tensile properties of the DTML in normal specimens and to compare these results with hallux valgus specimens. We hypothesized that the tensile properties of the DTML would be different between the 2 groups of specimens. The DTML in the first interspace was dissected from 12 fresh frozen human cadaveric specimens. Six cadavers had bilateral hallux valgus and the other 6 cadavers had normal feet. The initial length (L0) and cross-sectional area (A0) of the DTML were measured using a digital caliper, and tensile tests with load failure were performed using a material testing machine. There were significant between-groups differences in the initial length (L0) P = 0.009 and cross-sectional area (A0) of the DTML P = 0.007. There were also significant between-groups differences for maximum force (N) P = 0.004, maximum distance (mm) P = 0.005, maximum stress (N/mm2) P = 0.003, and maximum strain (%) P = 0.006. The DTML is an anatomical structure for which the tensile properties differ in hallux valgus.

21 September 2021 in Frontiers in Surgery
Verified
Journal Article
Open access
SASahar Abdalbary
Sahar Abdalbary
MAMohamed Abdel-Wahed
Mohamed Abdel-Wahed
SASherif Amr
Sherif Amr
MMMostafa Mahmoud
Mostafa Mahmoud
EEEhab A. A. El-Shaarawy
Ehab A. A. El-Shaarawy
AFAmal Fares
Amal Fares
Purpose: This study aims to histologically compare the median nerve in the arm, forearm, and wrist, to help understand how cervical radiculopathy in a double crush phenomenon causes distal nerve dysfunction at the carpal tunnel and median nerve with concurrent absence of symptoms at the forearm.Methods: The study was performed on 12 fresh cadaveric upper limbs free from any injury or operation. Male cadavers in the age range of 35–40 years were used. The dissection of the median nerve and the histological examination of the specimens from the arm, forearm, and wrist were conducted to evaluate variations in the epineurium thickness (μm), perineurium thickness (μm), number of fascicles per nerve trunk, area percent of myelin covering, and area percent of neurolemmal sheath.Results: Morphometric and statistical results of the cadaveric median nerve trunk revealed that the mean epineurium and perineurium thickness measured in H&E-stained sections in the forearm were significantly greater than those in the arm and wrist specimens. Further, the mean percent area of the myelin covering in the forearm was significantly lower than that in the arm and wrist specimens in the sections stained with osmium oxide (p < 0.001). There were, however, no significant differences in the neurolemmal sheath among the arm, forearm, and wrist specimens in the silver-stained sections.Conclusion: The histological differences explained the high concomitant occurrence of carpal tunnel syndrome (CTS) and cervical radiculopathy and the concurrent absence of symptoms at the forearm. Hence, we suggest cautious evaluation of patients with upper limb symptoms, since the management of these conditions requires a different approach.

12 September 2024 in Coatings
Verified
Journal Article
Open access
PDF file
AAAbdulaziz Alhotan
Abdulaziz Alhotan
SASaleh Alhijji
Saleh Alhijji
SASahar Abdalbary
Sahar Abdalbary
RBRania E. Bayoumi
Rania E. Bayoumi
JMJukka Matinlinna
Jukka Matinlinna
RARasha M. Abdelraouf
Rasha M. Abdelraouf
Polymer 3D printing has is used in a wide range of applications in the medical field. Polyamide 12 (PA12) is a versatile synthetic polymer that has been used to reconstruct bony defects. Coating its surface with calcium phosphate compounds, such as hydroxyapatite (HA), could enhance its bonding with bone. The aim of this study was to coat 3D-printed polyamide 12 specimens with hydroxyapatite by a simple innovative surface treatment using light-cured resin cement. Polyamide 12 powder was printed by selective laser sintering to produce 80 disc-shaped specimens (15 mm diameter × 1.5 mm thickness). The specimens were divided randomly into two main groups: (1) control group (untreated), where the surface of the specimens was left without any modifications; (2) treated group, where the surface of the specimens was coated with hydroxyapatite by a new method using a light-cured dental cement. The coated specimens were characterised by both Fourier transform infrared spectroscopy (FTIR) and Transmission Electron Microscopy (TEM), (n = 10/test). The control and treated groups were further randomly subdivided into two subgroups according to the immersion in phosphate-buffered saline (PBS). The first subgroup was not immersed in PBS and was left as 3D-printed, while the second subgroup was immersed in PBS for 15 days (n = 10/subgroup). The surfaces of the control and treated specimens were examined using an environmental scanning electron microscope (SEM) and energy dispersive X-ray analysis (EDXA) before and after immersion in PBS. Following the standard American Society for Testing and Materials (ASTM D3359), a cross-cut adhesion test was performed. The results of the FTIR spectroscopy of the coated specimens were confirmed the HA bands. The TEM micrograph revealed agglomerated particles in the coat. The SEM micrographs of the control 3D-printed polyamide 12 specimens illustrated the sintered 3D-printed particles with minimal porosity. Their EDXA revealed the presence of carbon, nitrogen, and oxygen as atomic%: 52.1, 23.8, 24.1 respectively. After immersion in PBS, there were no major changes in the control specimens as detected by SEM and EDXA. The microstructure of the coated specimens showed deposited clusters of calcium and phosphorus on the surface, in addition to carbon, nitrogen, and oxygen, with atomic%: 9.5, 5.9, 7.2, 30.9, and 46.5, respectively. This coat was stable after immersion, as observed by SEM and EDXA. The coat adhesion test demonstrated a stable coat with just a few loose coating flakes (area removed <5%) on the surface of the HA-coated specimens. It could be concluded that the 3D-printed polyamide 12 could be coated with hydroxyapatite using light-cured resin cement.

3 September 2021 in Frontiers in Surgery
Verified
Journal Article
Open access
SASahar Abdalbary
Sahar Abdalbary
SASherif M. Amr
Sherif M. Amr
KAKhaled Abdelghany
Khaled Abdelghany
ANAmr A. Nssef
Amr A. Nssef
EEEhab A. A. El-Shaarawy
Ehab A. A. El-Shaarawy
Introduction: This case report describes the reconstruction of a severe comminuted fracture and bone defect in the lateral half of the clavicle using a novel titanium prosthesis. This unique prosthesis has been specifically designed and three dimensionally printed for the clavicle, as opposed to the Oklahoma cemented composite prosthesis used in common practice. The aims of this study were to: (1) describe the prosthesis, its stress analysis, and its surgical fixation and (2) to demonstrate the results of the 2-year follow-up of the patient with the lateral clavicle prosthesis.Patient's Main Concerns: A 20-year-old, right-handed woman complaining of severe pain in the right shoulder was admitted to our hospital following a traffic accident. Physical examination revealed pain, swelling, tenderness, limb weakness, asymmetric posturing, and loss of function in the right shoulder.Diagnosis, Intervention, and Outcomes: Radiographic evaluation in the emergency room showed complete destruction with a comminuted fracture of the lateral half of the right clavicle and a comminuted fracture of the coracoid. We designed a new prosthesis for the lateral half of the clavicle, which was then tested by finite element analysis and implanted. Use of the new prosthesis was effective in the reconstruction of the comminuted fracture in the lateral half of the clavicle. After 2 years of follow-up, the patient had an aesthetically acceptable curve and was able to perform her activities of daily living. Her pain was relieved, and the disabilities of the arm, shoulder, and hand score improved. Active range of motion of the shoulder joint and muscle strength were also improved.Conclusion: This novel prosthesis is recommended for reconstruction of the lateral half of the clavicle following development of bony defects due to fracture. Our patient achieved functional and aesthetic satisfaction with this prosthesis.