Ángel Maquieira

Dr. Ángel Maquieira

1. Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, 46022 Valencia, Spain
+1
orcid

Research Focus & Metrics

Academic Career Length

43Years (1984-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2010 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
CCConsuelo Cháfer-Pericás
Consuelo Cháfer-Pericás
Ángel MaquieiraÁngel Maquieira
Ángel Maquieira
RPRosa Puchades
Rosa Puchades

1 May 2002 in Bioresource Technology
Verified
Journal Article
Closed access
MAManuel Abad
Manuel Abad
PNPatricia Noguera
Patricia Noguera
RPRosa Puchades
Rosa Puchades
Ángel MaquieiraÁngel Maquieira
Ángel Maquieira
VNVicente Noguera
Vicente Noguera

12 November 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CCC. F. Carlborg
C. F. Carlborg
KGKristinn Gylfason
Kristinn Gylfason
Andrzej KaźmierczakAndrzej Kaźmierczak
Andrzej Kaźmierczak
FDFabian Dortu
Fabian Dortu
MBMaria-Jose Bañuls
Maria-Jose Bañuls
WWW. van der Wijngaart
W. van der Wijngaart
We present the design, fabrication, and characterisation of an array of optical slot-waveguide ring resonator sensors, integrated with microfluidic sample handling in a compact cartridge, for multiplexed real-time label-free biosensing. Multiplexing not only enables high throughput, but also provides reference channels for drift compensation and control experiments. Our use of alignment tolerant surface gratings to couple light into the optical chip enables quick replacement of cartridges in the read-out instrument. Furthermore, our novel use of a dual surface-energy adhesive film to bond a hard plastic shell directly to the PDMS microfluidic network allows for fast and leak-tight assembly of compact cartridges with tightly spaced fluidic interconnects. The high sensitivity of the slot-waveguide resonators, combined with on-chip referencing and physical modelling, yields a volume refractive index detection limit of 5 × 10−6 refractive index units (RIUs) and a surface mass density detection limit of 0.9 pg mm−2, to our knowledge the best reported values for integrated planar ring resonators.

24 August 2010 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
ECEstela Climent
Estela Climent
RMRamón Martínez-Máñez
Ramón Martínez-Máñez
FSFélix Sancenón
Félix Sancenón
MMM. Dolores Marcos
M. Dolores Marcos
JSJuan Soto
Juan Soto
Pedro AmorósPedro Amorós
Pedro Amorós

9 September 2009 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
ECEstela Climent
Estela Climent
Andrea BernardosAndrea Bernardos
Andrea Bernardos
RMRamón Martínez-Máñez
Ramón Martínez-Máñez
Ángel MaquieiraÁngel Maquieira
Ángel Maquieira
MMM. Dolores Marcos
M. Dolores Marcos
Pedro AmorósPedro Amorós
Pedro Amorós

28 March 2008 in Optics Letters
Verified
Journal Article
Open access
PDF file
Carlos  BarriosCarlos Barrios
Carlos Barrios
MBMaria-Jose Bañuls
Maria-Jose Bañuls
VGVictoria González-Pedro
Victoria González-Pedro
KGKristinn Gylfason
Kristinn Gylfason
BSBenito Sánchez
Benito Sánchez
RCR. Casquel
R. Casquel
We demonstrate label-free molecule detection by using an integrated biosensor based on a Si3N4∕SiO2 slot-waveguide microring resonator. Bovine serum albumin (BSA) and anti-BSA molecular binding events on the sensor surface are monitored through the measurement of resonant wavelength shifts with varying biomolecule concentrations. The biosensor exhibited sensitivities of 1.8 and 3.2nm∕(ng∕mm2) for the detection of anti-BSA and BSA, respectively. The estimated detection limits are 28 and 16pg∕mm2 for anti-BSA and BSA, respectively, limited by wavelength resolution.