Aizhan Issatayeva

Dr. Aizhan Issatayeva


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Aizhan IssatayevaAizhan Issatayeva
Aizhan Issatayeva
ABAidana Beisenova
Aidana Beisenova
Daniele TosiDaniele Tosi
Daniele Tosi
CMCarlo Molardi
Carlo Molardi
Wearable light textiles are gaining widespread interest in application for measurement and monitoring of biophysical parameters. Fiber optic sensors, in particular Bragg Grating (FBG) sensors, can be a competitive method for monitoring of respiratory behavior for chest and abdomen regions since the sensors are able to convert physical movement into wavelength shift. This study aims to show the performance of elastic belts with integrated optical fibers during the breathing activities done by two volunteers. Additionally, the work aims to determine how the positions of the volunteers affect the breathing pattern detected by optical fibers. As a reference, commercial mobile application for sensing vibration is used. The obtained results show that the FBGs are able to detect chest and abdomen movements during breathing and consequently reconstruct the breathing pattern. The accuracy of the results varies for two volunteers but remains consistent.

15 May 2019 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
ABAidana Beisenova
Aidana Beisenova
Aizhan IssatayevaAizhan Issatayeva
Aizhan Issatayeva
SKSanzhar Korganbayev
Sanzhar Korganbayev
CMCarlo Molardi
Carlo Molardi
Wilfried BlancWilfried Blanc
Wilfried Blanc
Daniele TosiDaniele Tosi
Daniele Tosi
We introduce a novel multiplexing technique applied to optical fiber distributed sensors, based on optical backscatter reflectometry (OBR) and high-scattering MgO-doped fibers. In this work, we demonstrate the possibility of simultaneously detecting multiple fiber with a single scan using an OBR distributed sensor, and successfully discriminating each sensing region (with $\sim$ 1 mm spatial resolution). The sensing element is a high-scattering fiber with MgO-based nanoparticles doping in the core, that emits a scattering signal more than 40 dB larger than a standard fiber, while having similar temperature and strain sensitivity. Multiplexing occurs as the scattered light from a sensing fiber overshadows the amount of scattering occurring in all the other channels. The setup has been validated for temperature sensing and implemented in an epidural catheter with multiple fibers fixed to the outer walls for strain sensing. The proposed solution goes beyond the multiplexing methods which exploit 1 $\times$ N switches, as the multiplexing is simultaneous and not rearranged in different time slots.

15 September 2023 in Talanta
Verified
Journal Article
Open access
Aizhan IssatayevaAizhan Issatayeva
Aizhan Issatayeva
EFEdoardo Farnesi
Edoardo Farnesi
DCDana Cialla-May
Dana Cialla-May
MSMichael Schmitt
Michael Schmitt
FRFederica Rizzi
Federica Rizzi
ACAnnamaria Cucinotta
Annamaria Cucinotta
Genomic biomarkers of cancer are based on changes in nucleic acids, which include abnormal expression levels of some miRNAs, point mutations in DNA sequences, and altered levels of DNA methylation. The presence of tumor-related nucleic acids in body fluids (blood, saliva, or urine) makes it possible to achieve a non-invasive early-stage cancer diagnosis. Currently existing techniques for the discovery of nucleic acids require complex, time-consuming, costly assays and have limited multiplexing abilities. Surface-enhanced Raman spectroscopy (SERS) is a vibrational spectroscopy technique that is able to provide molecular specificity combined with trace sensitivity. SERS has gained research attention as a tool for the detection of nucleic acids because of its promising potential: label-free SERS can decrease the complexity of assays currently used with fluorescence-based detection due to the absence of the label, while labeled SERS may outperform the gold standard in terms of the multiplexing ability. The first papers about SERS-based methods for the measurement of genomic biomarkers were written in 2008, and since then, more than 150 papers have been published. The aim of this paper is to review and evaluate the proposed SERS-based methods in terms of their level of development and their potential for liquid biopsy application, as well as to contribute to their further evolution by attracting research attention to the field. This goal will be reached by grouping, on the basis of their experimental protocol, all the published manuscripts on the topic and evaluating each group in terms of its limit of detection and applicability to real body fluids. Thus, the methods are classified according to their working principles into five main groups, including capture-based, displacement-based, sandwich-based, enzyme-assisted, and specialized protocols.

13 August 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ABAidana Beisenova
Aidana Beisenova
Aizhan IssatayevaAizhan Issatayeva
Aizhan Issatayeva
Daniele TosiDaniele Tosi
Daniele Tosi
CMCarlo Molardi
Carlo Molardi
Epidural anesthesia is a pain relief treatment mainly used for pregnant women during delivery. The procedure is described as an injection of anesthetic fluid into an epidural space using a hemodynamic Tuohy needle. The correct identification of epidural space is crucial for successful anesthesia, but due to the blindness of the procedure, the existing methods can fail with potentially severe consequences for patients. Since the tissue preceding the epidural space has high density, the strain significantly changes when the needle reaches the proximity of the epidural space, and this change can be used as an indicator. Distributed fiber optic sensors, working with an optical backscatter reflectometer, can improve the scenario by measuring the strain along each section of the epidural needle. This work goes beyond the epidural space identification: distributed strain data detect strain events leading to a potential failure to reach the epidural space before the procedure is finalized. The experiments have shown that the penetrations along different paths (with different speeds, with misalignment, and with rotation) result in different strain patterns. The proposed method has been validated on phantoms reproducing the epidural space, in different insertion conditions.

27 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ABAidana Beisenova
Aidana Beisenova
Aizhan IssatayevaAizhan Issatayeva
Aizhan Issatayeva
ZAZhannat Ashikbayeva
Zhannat Ashikbayeva
MJMadina Jelbuldina
Madina Jelbuldina
AAArman Aitkulov
Arman Aitkulov
Daniele TosiDaniele Tosi
Daniele Tosi
Thermal ablation is achieved by delivering heat directly to tissue through a minimally invasive applicator. The therapy requires a temperature control between 50–100 °C since the mortality of the tumor is directly connected with the thermal dosimetry. Existing temperature monitoring techniques have limitations such as single-point monitoring, require costly equipment, and expose patients to X-ray radiation. Therefore, it is important to explore an alternative sensing solution, which can accurately monitor temperature over the whole ablated region. The work aims to propose a distributed fiber optic sensor as a potential candidate for this application due to the small size, high resolution, bio-compatibility, and temperature sensitivity of the optical fibers. The working principle is based on spatial multiplexing of optical fibers to achieve 3D temperature monitoring. The multiplexing is achieved by high-scattering, nanoparticle-doped fibers as sensing fibers, which are spatially separated by lower-scattering level of single-mode fibers. The setup, consisting of twelve sensing fibers, monitors tissue of 16 mm × 16 mm × 25 mm in size exposed to a gold nanoparticle-mediated microwave ablation. The results provide real-time 3D thermal maps of the whole ablated region with a high resolution. The setup allows for identification of the asymmetry in the temperature distribution over the tissue and adjustment of the applicator to follow the allowed temperature limits.

21 February 2025 in Journal of Optics
Verified
Journal Article
Open access
Aizhan IssatayevaAizhan Issatayeva
Aizhan Issatayeva
SMSiddra Maryam
Siddra Maryam
KKKiang Wei Kho
Kiang Wei Kho
SAStefan Andersson-Engels
Stefan Andersson-Engels
ACAnnamaria Cucinotta
Annamaria Cucinotta
Photonic crystal fiber (PCF) can be used as a microfluidic platform for surface-enhanced Raman spectroscopy (SERS)-based measurement of different samples. PCF can provide a long area of interaction for light, metal nanoparticles (NPs), and analytes incorporated into its holes. This paper provides a COMSOL simulation model for suspended-core PCF used to evaluate the SERS intensity depending on the fiber’s geometry and NPs’ coverage density. The simulation is applied to compare three PCFs with varying sizes and lengths. SERS measurements of adenine and DNA validate the simulation outcomes and demonstrate the potential of PCFs for SERS-based detection of diverse samples.