Background: COVID-19 vaccines were made available to the public by the end of 2020. However, little is known about COVID-19 booster dose (CBD) vaccine perception among healthcare workers (HCW) worldwide. The present study aims to assess the perception of CBD vaccines among healthcare workers in India and Saudi Arabia (SA). Methods: A cross-sectional study was conducted among HCWs in two countries, India and SA. Data were gathered through the use of a self-administered questionnaire. A convenience sampling technique was utilized to collect the data. Results: A total of 833 HCW responses were collected from the two countries, with 530 participants from India and 303 participants from SA responding to the questionnaire. Among them, 16% from India and 33% from SA were unwilling to take a CBD (p < 0.005). The primary reasons for not being willing were concerns about whether the vaccine would be effective (32%) and concerns about probable long-term side effects (31%). Concerns about not knowing enough about the vaccination (30%) and the possibility of long-term side effects (28%) were the primary concerns in SA. Regression analysis showed that males, urban residents, and post-graduates were more willing to take the CBD. Conclusion: There is a good perception of CBD and some hesitancy in receiving the booster dose among HCWs in both countries. The introduction of personalized education, risk communication, and deliberate policy could help to reduce the number of people who are unwilling to take a booster shot.
Various 3D printing systems for interim fixed dental restorations are commercially available. This study aimed to evaluate the physical and mechanical properties of 3D printed resins used for interim restorations fabricated using various 3D printing systems and printing angulations after accelerated aging. Three different interim restorative materials were provided and printed using their specific 3D printing systems (A: NextDent; B: Asiga; C: Nova3D), and the testing specimens from each system were printed at two building angles: (1) 0° and (2) 90°. The six groups were A1, A2, B1, B2, C1, and C2, with sixteen specimens per group. Half of the specimens in each group (N = 8) were subjected to accelerated aging, including simulated brushing and thermocycling. Three-point bending, surface roughness, and Vickers microhardness tests were performed. Two-way ANOVA and Fisher’s multiple tests were used for statistical analyses. The most accurate systems were found in groups C1 and C2 for length, A1 and B1 for width, and A1 and C1 for height. The specimen trueness only changed after aging for groups B1, B2, and C1. The flexural strength of the A2 group (151 ± 7 MPa) before aging was higher than that of the other groups, and the strength decreased after aging only for groups A1 and A2. The flexural strength, microhardness, and surface roughness of the 3D printed interim resins after aging varied depending on the material, system used, and printing angle.
1 January 2019 in Journal of the Mechanical Behavior of Biomedical Materials
This study evaluated the strength, hardness, and color stability of 3D-printed denture base resins and compared the outcome with conventional heat-cured denture base resins after aging by thermocycling. A total of 72 specimens from conventional and 3D-printed materials were fabricated in different shapes and dimensions based on the mechanical and color tests performed. The specimens were divided into five groups: flexural, tensile, and compressive strengths (n = 20), hardness, and color stability (n = 6). In all these groups, half of the specimens were stored in a distilled water bath at 37 °C for 24 h, and the remaining half of the specimens were subjected to aging by thermocycling. The 3D-printed specimens demonstrated the highest means of tensile strength (32.20 ± 3.8 MPa), compressive strength (106.31 ± 4.07 MPa), and Vickers hardness number (24.51 ± 0.36), and the lowest means of flexural strength (54.29 ± 13.17 MPa) and color difference (ΔE = 2.18 ± 1.09). Conventional heat-cured specimens demonstrated the highest means of flexural strength (59.96 ± 8.39 MPa) and color difference (ΔE = 4.74 ± 2.37) and the lowest means of tensile strength (32.17 ± 9.06 MPa), compressive strength (46.05 ± 4.98 MPa), and Vickers hardness number (10.42 ± 1.05). Aging significantly reduced the flexural strength (−27%), tensile strength (−44%), and hardness (−7%) of 3D-printed resins in contrast to the conventional resin’s compressive strength (−15%) and color stability (p < 0.05). The 3D-printed resin had comparable flexural and tensile strength and significantly superior compressive strength, hardness, and color stability compared with conventional resins. Aging significantly and negatively affected the flexural strength, tensile strength, and hardness of 3D-printed resin.
This in vitro study evaluated the influence of combined coffee staining and simulated brushing-induced color changes and surface roughness on 3D-printed orthodontic retainers. Specimens measuring 10 × 10 × 0.75 mm3 were obtained either by conventional vacuum forming or 3D printing at four print angulations (0°, 15°, 30°, and 45°) (n = 10). The prepared specimens were immersed in a coffee beverage and then mechanically brushed using a simulating device. The specimen’s color difference (ΔE) and surface roughness (Ra) were quantified using a spectrophotometer and a non-contact profilometer, respectively. The highest and lowest mean ΔE values were recorded for the 3D-printed-45° (4.68 ± 2.07) and conventional (2.18 ± 0.87) groups, respectively. The overall mean comparison of ΔE between the conventional and 3D-printed groups was statistically significant (p < 0.01). After simulated brushing, all groups showed a statistically significant increase in the Ra values (p < 0.01). The highest Ra was in the 3D-printed-45° (1.009 ± 0.13 µm) and conventional (0.743 ± 0.12 µm) groups, respectively. The overall ΔE of 3D-printed orthodontic retainers was not comparable to conventional VFRs. Among the different angulations used to print the retainers, 15° angulations were the most efficient in terms of color changes and surface roughness and were comparable to conventional VFRs.