Yuan Wang

Dr. Yuan Wang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
YWYuan Wang
Yuan Wang
GMGuo-Ming Ma
Guo-Ming Ma
DZDiya Zheng
Diya Zheng
WQWei-Qi Qin
Wei-Qi Qin
JJJun Jiang
Jun Jiang
CYChao Yan
Chao Yan

15 September 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YWYuan Wang
Yuan Wang
GMGuo-Ming Ma
Guo-Ming Ma
DZDiya Zheng
Diya Zheng
WLWenlin Liao
Wenlin Liao
JJJun Jiang
Jun Jiang
WQWeiqi Qin
Weiqi Qin
Dissolved gas analysis (DGA) is an important online monitoring technique for power transformers. When there are some faults in oil-immersed transformers, insulation materials will decompose into various small-molecule gases and continually dissolve in transformer oil. In order to figure out the composition and the concentration of dissolved gases, an optical gas sensing system based on photonic crystal fiber was developed. Hollow core photonic crystal fiber (HC-PCF) used in the system played the role of an absorption gas cell. The gas diffusion time was studied theoretically and experimentally, and the result showed that by using a 1.0 m length long HC-PCF, the theoretical diffusion time for acetylene was about 3.47 hours. Various acetylene gas samples got detected. Through Allan variance analysis, the sensitivity of the proposed sensing system could reach the best with the highest signal-to-noise ratio (SNR) when the average time was 29 s, and a minimum detection limit of 4.5 ppm could be achieved. The proposed sensing system showed tremendous advantages, such as low detection limit, no cross interference, high sensitivity. This gas sensing technique has a good application prospect in DGA for power transformers.

12 January 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TGTing-Yu Gao
Ting-Yu Gao
GMGuo-Ming Ma
Guo-Ming Ma
YWYu-Kun Wang
Yu-Kun Wang
DGDan Gao
Dan Gao
WQWeiqi Qin
Weiqi Qin
CYChao Yan
Chao Yan
Magnetic field sensor based on non-adiabatic tapered optical fiber (NATOF) surrounded with magnetic fluid (MF) has a potential to detect ultra-weak magnetic field. In order to improve the sensitivity of the magnetic field sensor, this paper investigated the effect of structure on sensitivity. The interference occurring between the modes in cladding and MF was analyzed to obtain the relationship between sensitivity and diameter of the tapered waist. Experiments were carried out to verify the proposed relationship. The experiments indicated when the diameter was larger than dispersion turning point ( $8.75 ~\mu \text{m}$ ), the sensitivity of the sensor decreased with the diameter of the tapered waist. The largest sensitivity obtained in the experiment is 6.567 nm/mT under a weak magnetic flux density range from 0 mT to 5 mT. This result is instructive for the manufacture of sensors with specific sensitivity.

1 September 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WQWeiqi Qin
Weiqi Qin
GMGuo-Ming Ma
Guo-Ming Ma
SWSihan Wang
Sihan Wang
JHJing Hu
Jing Hu
ZLZhongqin Lin
Zhongqin Lin
YWYuan Wang
Yuan Wang
To realize the highly sensitive multiple-point detection of partial discharge (PD) acoustic emission (AE) in power transformers, an ultrasonic sensing system based on a distributed feedback fiber laser (DFB-FL) array was proposed. Four DFB-FLs were connected on a single optical fiber as sensing elements to synchronously detect PD AE signals. The heterodyne coherent detection structure was formed by introducing an acousto-optic modulator (AOM) into the unbalanced Mach-Zehnder interferometer (MZI) to realize the rapid and highly sensitive demodulation of ultrasonic signals. The influence of noises and arm length difference on the lower limit of detection (LLOD) were theoretically discussed and experimentally verified. By adopting a 70-meter-long delay fiber, the proposed system performed a 9.54 dB lower average detection limit than that of PZT. Finally, based on the proposed system, a partial discharge source was accurately located in a 1000 mm×1000 mm×1100 mm oil tank, and the localization error was 24.6 mm. The proposed method exhibited promising application prospects in sensitivity, installation convenience, anti-interference and reliability.

14 May 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YWYuan Wang
Yuan Wang
GMGuo-Ming Ma
Guo-Ming Ma
DZDiya Zheng
Diya Zheng
JJJun Jiang
Jun Jiang
CYChao Yan
Chao Yan
Gas detection plays an important role in many fields, such as atmospheric environment monitoring, biological monitoring, gas leakage monitoring, gas decomposition products detection, and so on. Nowadays, there are many kinds of gas sensors. Compared with normal gas sensors, optical sensors have the advantages of antielectromagnetic interference, high sensitivity, and compact size. Especially in certain extreme conditions, such as in aerospace applications and oil exploration application, optical fiber sensors are more attractive. This article presents a critical review on fiber loop ring-down spectroscopy (FLRDS), which can be used for quantitative detection of concentrations of trace gases. Fiber cavity is the core component of FLRDS system. The principles, loss characteristics, and application ranges of different types of fiber cavities are discussed. This article brings a variety of FLRDS techniques and introduces the basis for each technique, recent developments in methods, and performance limitations in detail. Finally, the existing technical barriers and future prospects of the FLRDS system for gas sensing are presented.

12 April 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DGDan Gao
Dan Gao
GMGuo-Ming Ma
Guo-Ming Ma
WQWeiqi Qin
Weiqi Qin
TGTingyu Gao
Tingyu Gao
YWYukun Wang
Yukun Wang
HZHongyang Zhou
Hongyang Zhou
To solve the power supply, signal communication, and lifetime problems in the humidity sensing in power cable tunnel, an intrinsic non-adiabatic tapered optical fiber (NATOF) relative humidity (RH) sensor without functional film was proposed in this article. The sensing principle based on multimode interference and refractive index (RI) sensitivity was introduced. The relationship between humidity sensitivity and the waist diameter of NATOF was theoretically analyzed to improve the sensor sensitivity. It is found that high relative humidity sensitivity detection can be achieved by taking advantage of the NATOF’s high sensitivity near the dispersion turning point (DTP). The test-obtained trends of the humidity sensitivity at different waist diameters were consistent with the theoretical results. The proposed NATOF sensor with a waist diameter of 2.39 $\mu \text{m}$ had a linear response in the range of 35%–90% RH, a detection distance of over 10 km, a relative humidity sensitivity of −47 pm/% RH, and an accuracy of ±4.6% RH. Based on the different response sensitivities to humidity and temperature of different dips, a sensing matrix was established to solve the temperature cross-sensitivity issue of the relative humidity sensor.