Theresa Sophie Patzer

Dr. Theresa Sophie Patzer

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2023 in European Radiology
Verified
Journal Article
Open access
PDF file
TPTheresa Sophie Patzer
Theresa Sophie Patzer
AKAndreas Steven Kunz
Andreas Steven Kunz
HHHenner Huflage
Henner Huflage
PGPhilipp Gruschwitz
Philipp Gruschwitz
PPPauline Pannenbecker
Pauline Pannenbecker
JGJan-Peter Grunz
Jan-Peter Grunz
Objectives: While established for energy-integrating detector computed tomography (CT), the effect of virtual monoenergetic imaging (VMI) and iterative metal artifact reduction (iMAR) in photon-counting detector (PCD) CT lacks thorough investigation. This study evaluates VMI, iMAR, and combinations thereof in PCD-CT of patients with dental implants. Material and methods: In 50 patients (25 women; mean age 62.0 ± 9.9 years), polychromatic 120 kVp imaging (T3D), VMI, T3DiMAR, and VMIiMAR were compared. VMIs were reconstructed at 40, 70, 110, 150, and 190 keV. Artifact reduction was assessed by attenuation and noise measurements in the most hyper- and hypodense artifacts, as well as in artifact-impaired soft tissue of the mouth floor. Three readers subjectively evaluated artifact extent and soft tissue interpretability. Furthermore, new artifacts through overcorrection were assessed. Results: iMAR reduced hyper-/hypodense artifacts (T3D 1305.0/−1418.4 versus T3DiMAR 103.2/−46.9 HU), soft tissue impairment (106.7 versus 39.7 HU), and image noise (16.9 versus 5.2 HU) compared to non-iMAR datasets (p ≤ 0.001). VMIiMAR ≥ 110 keV subjectively enhanced artifact reduction over T3DiMAR (p ≤ 0.023). Without iMAR, VMI displayed no measurable artifact reduction (p ≥ 0.186) and facilitated no significant denoising over T3D (p ≥ 0.366). However, VMI ≥ 110 keV reduced soft tissue impairment (p ≤ 0.009). VMIiMAR ≥ 110 keV resulted in less overcorrection than T3DiMAR (p ≤ 0.001). Inter-reader reliability was moderate/good for hyperdense (0.707), hypodense (0.802), and soft tissue artifacts (0.804). Conclusion: While VMI alone holds minimal metal artifact reduction potential, iMAR post-processing enabled substantial reduction of hyperdense and hypodense artifacts. The combination of VMI ≥ 110 keV and iMAR resulted in the least extensive metal artifacts. Clinical relevance: Combining iMAR with VMI represents a potent tool for maxillofacial PCD-CT with dental implants achieving substantial artifact reduction and high image quality. Key Points: • Post-processing of photon-counting CT scans with an iterative metal artifact reduction algorithm substantially reduces hyperdense and hypodense artifacts arising from dental implants. • Virtual monoenergetic images presented only minimal metal artifact reduction potential. • The combination of both provided a considerable benefit in subjective analysis compared to iterative metal artifact reduction alone.

20 October 2022 in Radiography
Verified
Journal Article
Closed access
HHHenner Huflage
Henner Huflage
JGJan-Peter Grunz
Jan-Peter Grunz
AKAndreas Steven Kunz
Andreas Steven Kunz
TPTheresa Sophie Patzer
Theresa Sophie Patzer
SSStephanie Sauer
Stephanie Sauer
KLKarsten Sebastian Luetkens
Karsten Sebastian Luetkens


1 July 2024 in Radiology
Verified
Journal Article
Closed access
HHHenner Huflage
Henner Huflage
AKAndreas Steven Kunz
Andreas Steven Kunz
TPTheresa Sophie Patzer
Theresa Sophie Patzer
SPSvenja Pichlmeier
Svenja Pichlmeier
TWThilo Westhofen
Thilo Westhofen
JGJan-Peter Grunz
Jan-Peter Grunz
Abdominal photon-counting CT with tin prefiltration enabled submillisievert urolithiasis imaging with high image quality, and radiation exposure was reduced by 44% compared with dose-optimized energy-integrating detector CT.

19 November 2023 in European Journal of Radiology
Verified
Journal Article
Closed access
TPTheresa Sophie Patzer
Theresa Sophie Patzer
JGJan-Peter Grunz
Jan-Peter Grunz
HHHenner Huflage
Henner Huflage
JHJan-Lucca Hennes
Jan-Lucca Hennes
PPPauline Pannenbecker
Pauline Pannenbecker
AKAndreas Steven Kunz
Andreas Steven Kunz

1 March 2023 in Radiology
Verified
Journal Article
Closed access
AKAndreas Steven Kunz
Andreas Steven Kunz
JSJonas Schmalzl
Jonas Schmalzl
HHHenner Huflage
Henner Huflage
KLKarsten Sebastian Luetkens
Karsten Sebastian Luetkens
TPTheresa Sophie Patzer
Theresa Sophie Patzer
JGJan-Peter Grunz
Jan-Peter Grunz
Gantry-free cone-beam CT with a twin robotic radiography system allows for excellent diagnostic performance for the diagnosis of fractures and fracture-related findings in elbow joint examinations ... Background Posttraumatic CT imaging of the elbow can be challenging when patient mobility is limited. Gantry-free cone-beam CT (CBCT) with a twin robotic radiography system offers greater degrees o...