Karsten Sebastian Luetkens

Dr. Karsten Sebastian Luetkens

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2024 in Rheumatology International
Verified
Journal Article
Open access
PDF file
PSPatrick-Pascal Strunz
Patrick-Pascal Strunz
MMMaxime Le Maire
Maxime Le Maire
THTobias Heusinger
Tobias Heusinger
JKJuliana Klein
Juliana Klein
HLHannah Labinsky
Hannah Labinsky
MSMarc Schmalzing
Marc Schmalzing
Background: Patients with axial spondyloarthritis (axSpA) benefit from regular home-based exercise (HbE). In spite of recommendations, a relevant proportion of German axSpA patients does not adhere to recommended HbE practices. To enhance HbE care, we developed the novel digital therapeutic (DTx) “Axia” compliant with the European medical device regulation (MDR). Axia offers a modern app-based HbE solution with patient educative content and further integrated features. Objective: We aimed to assess Axia’s efficacy, attractiveness, and functionality through a survey among axSpA-patients involved in the first user tests. Methods: A mixed-method online questionnaire with 38 items was administered to 37 axSpA volunteers after using Axia. Numeric rating scales (NRS) and likelihood scales were primarily used. Results: HbE frequency significantly increased from a median of 1 day/week to 6 days/week (p < 0.001) by using Axia. Existing HbE practitioners also increased their frequency (median of 4 days/week before, 6 days/week with Axia, p < 0.05). Axia received a median rating of 5 out of 5 stars. On NRS scales, Axia scored a median of 9 for intuitiveness and design, and a median of 8 for entertainment. 64.9% reported improved range of motion, 43.2% reported reduced pain, and 93.6% enhanced disease-specific knowledge. All users recommended Axia to other patients. Conclusion: Axia increases axSpA patients HbE frequency, possibly due to its good intuitiveness and design, leading to reduction in pain and subjective improvement of range of motion. This warrants further investigation in large randomized controlled interventional trials to establish its efficacy conclusively and patients adherence to HbE.

20 October 2022 in Radiography
Verified
Journal Article
Closed access
HHHenner Huflage
Henner Huflage
JGJan-Peter Grunz
Jan-Peter Grunz
AKAndreas Steven Kunz
Andreas Steven Kunz
TPTheresa Sophie Patzer
Theresa Sophie Patzer
SSStephanie Sauer
Stephanie Sauer
KLKarsten Sebastian Luetkens
Karsten Sebastian Luetkens


1 October 2021 in European Journal of Radiology
Verified
Journal Article
Closed access
KLKarsten Sebastian Luetkens
Karsten Sebastian Luetkens
SLSusanne Franziska Laas
Susanne Franziska Laas
SHSylvia Haßler
Sylvia Haßler
TGTobias Gassenmaier
Tobias Gassenmaier
CGCarsten Herbert Gietzen
Carsten Herbert Gietzen
JGJan-Peter Grunz
Jan-Peter Grunz

1 March 2023 in Radiology
Verified
Journal Article
Closed access
AKAndreas Steven Kunz
Andreas Steven Kunz
JSJonas Schmalzl
Jonas Schmalzl
HHHenner Huflage
Henner Huflage
KLKarsten Sebastian Luetkens
Karsten Sebastian Luetkens
TPTheresa Sophie Patzer
Theresa Sophie Patzer
JGJan-Peter Grunz
Jan-Peter Grunz
Gantry-free cone-beam CT with a twin robotic radiography system allows for excellent diagnostic performance for the diagnosis of fractures and fracture-related findings in elbow joint examinations ... Background Posttraumatic CT imaging of the elbow can be challenging when patient mobility is limited. Gantry-free cone-beam CT (CBCT) with a twin robotic radiography system offers greater degrees o...

28 June 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
KLKarsten Sebastian Luetkens
Karsten Sebastian Luetkens
JGJan-Peter Grunz
Jan-Peter Grunz
AKAndreas Steven Kunz
Andreas Steven Kunz
HHHenner Huflage
Henner Huflage
WMWeißenberger Manuel
Weißenberger Manuel
PFPhilipp Feldle
Philipp Feldle
This study was designed to investigate the image quality of ultra-high-resolution ankle arthrography employing a photon-counting detector CT. Bilateral arthrograms were acquired in four cadaveric specimens with full-dose (10 mGy) and low-dose (3 mGy) scan protocols. Three convolution kernels with different spatial frequencies were utilized for image reconstruction (ρ50; Br98: 39.0, Br84: 22.6, Br76: 16.5 lp/cm). Seven radiologists subjectively assessed the image quality regarding the depiction of bone, hyaline cartilage, and ligaments. An additional quantitative assessment comprised the measurement of noise and the computation of contrast-to-noise ratios (CNR). While an optimal depiction of bone tissue was achieved with the ultra-sharp Br98 kernel (S ≤ 0.043), the visualization of cartilage improved with lower modulation transfer functions at each dose level (p ≤ 0.014). The interrater reliability ranged from good to excellent for all assessed tissues (intraclass correlation coefficient ≥ 0.805). The noise levels in subcutaneous fat decreased with reduced spatial frequency (p < 0.001). Notably, the low-dose Br76 matched the CNR of the full-dose Br84 (p > 0.999) and superseded Br98 (p < 0.001) in all tissues. Based on the reported results, a photon-counting detector CT arthrography of the ankle with an ultra-high-resolution collimation offers stellar image quality and tissue assessability, improving the evaluation of miniscule anatomical structures. While bone depiction was superior in combination with an ultra-sharp convolution kernel, soft tissue evaluation benefited from employing a lower spatial frequency.