Self-gated non–contrast-enhanced functional lung MR imaging allows for site-resolved assessment of quantitative pulmonary ventilation in patients with cystic fibrosis without contrast material application or breath holds. PurposeTo assess the clinical feasibility of self-gated non–contrast-enhanced functional lung (SENCEFUL) magnetic resonance (MR) imaging for quantitative ventilation (QV) imaging in patients with cystic fibrosis (CF).Materials and MethodsTwenty patients with CF and 20 matched healthy volunteers underwent functional 1.5-T lung MR imaging with the SENCEFUL imaging approach, in which a two-dimensional fast low-angle shot sequence is used with quasi-random sampling. The lungs were manually segmented on the ventilation-weighted images to obtain QV measurements, which were compared between groups. QV values of the patients were correlated with results of pulmonary function testing. Three radiologists rated the images for presence of ventilation deficits by means of visual inspection. Mann-Whitney U tests, receiver operating characteristic analyses, Spearman correlations, and Gwet agreement coefficient analyses were used for statistical analysis.ResultsQV of the entire lungs was lower for patients with CF than f...
Purpose To compare radiation dose, subjective and objective image quality of 3 rd generation dual-source CT (DSCT) and dual-energy CT (DECT) with conventional 64-slice single-source CT (SSCT) for pulmonary CTA. Materials and Methods 180 pulmonary CTA studies were performed in three patient cohorts of 60 patients each. Group 1: conventional SSCT 120 kV (ref.); group 2: single-energy DSCT 100 kV (ref.); group 3: DECT 90/Sn150 kV. CTDIvol, DLP, effective radiation dose were reported, and CT attenuation (HU) was measured on three central and peripheral levels. The signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. Two readers assessed subjective image quality according to a five-point scale. Results Mean CTDIvol and DLP were significantly lower in the dual-energy group compared to the SSCT group (p < 0.001 [CTDIvol]; p < 0.001 [DLP]) and the DSCT group (p = 0.003 [CTDIvol]; p = 0.003 [DLP]), respectively. The effective dose in the DECT group was 2.79 ± 0.95 mSv and significantly smaller than in the SSCT group (4.60 ± 1.68 mSv, p < 0.001) and the DSCT group (4.24 ± 2.69 mSv, p = 0.003). The SNR and CNR were significantly higher in the DSCT group (p < 0.001). Subjective image quality did not differ significantly among the three protocols and was rated good to excellent in 75 % (135/180) of cases with an inter-observer agreement of 80 %. Conclusion Dual-energy pulmonary CTA protocols of 3 rd generation dual-source scanners allow for significant reduction of radiation dose while providing excellent image quality and potential additional information by means of perfusion maps. Key Points: Citation Format
1 November 2024 in Radiology: Artificial Intelligence
The RSNA Abdominal Traumatic Injury CT (ie, RATIC) dataset contains 4274 abdominal CT studies with annotations related to traumatic injuries and is available at https://www.kaggle.com/competitions/rsna-2023-abdominal-trauma-detection and https://imaging.rsna.org/dataset/5 .