Inés Alcaraz

Dr. Inés Alcaraz


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2023 in Materials
Verified
Journal Article
Open access
PDF file
IAInés Alcaraz
Inés Alcaraz
JMJavier Moyano
Javier Moyano
APAriadna Pàmies
Ariadna Pàmies
GSGUILLEM RUIZ SABATE
GUILLEM RUIZ SABATE
MAMontserrat Artés
Montserrat Artés
Andreu PuigdollersAndreu Puigdollers
Andreu Puigdollers
The aim of the present study was to describe and determine changes in the superelastic properties of NiTi archwires after clinical use and sterilization. Ten archwires from five different manufacturers (GAC, 3M, ODS, GC, FOR) were cut into two segments and evaluated using a three-point bending test in accordance with ISO 14841:2006. The center of each segment was deflected to 3.1 mm and then unloaded to 0 N to obtain a load–deflection curve. Deflection at the end of the plateau and forces at 3, 2, 1 and 0.5 mm on the unloading curve were recorded. Plateau slopes were calculated at 2, 1 and 0.5 mm of deflection. Data obtained were statistically analyzed to determine differences (p < 0.001). Results showed that the degree of superelasticity and exerted forces differed significantly among brand groups. After three months of clinical use, FOR released a greater force for a longer activation period. GC, EURO and FOR archwires seemed to lose their mechanical properties. GC wires released more force than other brand wires after clinical use. Regarding superelasticity after sterilization, GAC, 3M and FOR wires recovered their properties, while EURO archwires lost more.

18 July 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
IAInés Alcaraz
Inés Alcaraz
JMJavier Moyano
Javier Moyano
APAriadna Pàmies
Ariadna Pàmies
GSGUILLEM RUIZ SABATE
GUILLEM RUIZ SABATE
MAMontserrat Artés
Montserrat Artés
Andreu PuigdollersAndreu Puigdollers
Andreu Puigdollers
The aim of the present study was to describe and determine changes in the superelastic properties of NiTi archwires after clinical use and sterilization. Ten archwires from five different manufacturers (GAC, 3M, ODS, GC, FOR) were cut in two segments and evaluated using a three-point bending test in accordance with ISO 14841:2006. The centre of each segment was deflected to 3.1mm and then unloaded to 0 N to obtain a load-deflection curve. Deflection at the end of the plateau and forces at 3, 2, 1 and 0.5mm on the unloading curve were recorded. Plateau slopes were calculated at 2, 1 and 0.5mm of deflection. Data obtained were statistically analysed to determine differences (p<0.001). Results showed that the degree of superelasticity and exerted forces differed significantly among brand groups. After three months of clinical use, FOR released a greater force for a longer activation period. GC, EURO and FOR archwires seemed to lose their mechanical properties. GC wires released more force than other brand wires after clinical use. Regarding superelasticity after sterilization, GAC, 3M and FOR wires recovered their properties, while EURO archwires lost more.

8 June 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
GSGUILLEM RUIZ SABATE
GUILLEM RUIZ SABATE
JMJavier Moyano
Javier Moyano
IAInés Alcaraz
Inés Alcaraz
NCNuria Clusellas-Barrionuevo
Nuria Clusellas-Barrionuevo
NMNúria Molina
Núria Molina
Andreu PuigdollersAndreu Puigdollers
Andreu Puigdollers
Background/Objectives: Changes in the mechanical behavior of orthodontic archwires during clinical use are not fully understood, particularly when different bracket systems are employed. Self-ligating (SL) brackets have gained considerable popularity in orthodontic practice in recent years, largely due to claims of improved treatment efficiency and biomechanical performance. Nevertheless, current evidence has not consistently demonstrated statistically significant differences between conventional ligation (CL) brackets and SL systems. The aim of this study was to evaluate changes in the mechanical properties and degradation over time of nickel-titanium (NiTi) archwires after clinical use in orthodontic treatments performed with CL and SL brackets. Methods: A comparative study was conducted using archwires retrieved from orthodontic patients. Round 0.014-inch NiTi wires (GC Orthodontics America Inc., IL, USA) were analyzed. The archwires were used in 60 patients treated with either CL or SL appliances and evaluated at four time points: before clinical use (T0), and after 1 month (T1), 2 months (T2), and 3 months (T3) of intraoral service. Mechanical testing was performed according to ISO 15841:2014 + Amd. 1:2020 using a three-point bending test with a universal testing machine (Z005 Test Control II Universal Testing Machine, Zwick Roell, Kennesaw, GA, USA). The variables analyzed included the mean force delivered by the archwires at deflections of 3 mm (F3), 2 mm (F2), 1 mm (F1), and 0.5 mm (F0.5), as well as the slope of the superelastic plateau at 2 mm, 1 mm, and 0.5 mm. The static and dynamic friction coefficients, as well as the friction forces associated with the wires and the two types of brackets, were determined using a modified MTS-Bionix servo-hydraulic testing machine. The tests were conducted at 37 °C in a saline environment. Results: Both groups showed changes in the superelastic behavior of NiTi archwires. Alterations increased with longer intraoral exposure. In the SL group, significant modifications were already observed after one month of clinical use, with a reduction in the force delivered and a loss of superelastic characteristics. These changes remained relatively stable thereafter, with no statistically significant differences during the following months. In contrast, the CL group showed a progressive reduction in force delivery and superelasticity over time. This is due to the difference in friction between the wire and the CL bracket compared to the SL bracket, which results in greater force transfer for tooth movement. Conclusions: Overall, differences in the mechanical behavior of archwires between CL and SL systems were observed during the initial stages of clinical use. However, these differences diminished over time, and no significant differences were detected after three months. Considering the progressive degradation of mechanical properties, the reuse of archwires that have remained intraorally for more than three months may not be advisable.