Yanwu Xu

Dr. Yanwu Xu

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YXYanwu Xu
Yanwu Xu
ZZZhuoran Zhang
Zhuoran Zhang
YJYunyi Jiang
Yunyi Jiang
JHJian Huang
Jian Huang
WJWenying Jiang
Wenying Jiang
Due to its high power density, the fractional slot concentrated winding (FSCW) permanent magnet synchronous machine (PMSM) is a competitive candidate for the aircraft starter generator (SG) system. However, the short circuit (SC) fault, especially the turn-to-turn SC fault, is the obstruct crux in aviation applications. The turn-to-turn SC current can be restricted to a permissible level with higher reactance and the current injection mitigation method. However, higher self-inductance always leads to lower power density. So far, there have been no numerical criteria for the trade-off between the two characteristics in machine design. In this paper, an analytical model based on flux distribution is used to estimate the SC current. The effectiveness of the d-axis current injection mitigation method is numerically analyzed in the series and parallel connected windings individually. The requirement for PMSMs to survive the turn-to-turn SC fault is derived. The mathematic analysis is verified by finite element analysis (FEA) and experiments on a 12-slot, 10-pole PMSM. The paper provides theoretical support for designing high-performance PMSG with SC current mitigation ability for the aviation power system.

30 October 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YXYanwu Xu
Yanwu Xu
ZZZhuoran Zhang
Zhuoran Zhang
ZBZhangming Bian
Zhangming Bian
LYLi Yu
Li Yu

12 May 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YXYanwu Xu
Yanwu Xu
ZZZhuoran Zhang
Zhuoran Zhang
ZBZhangming Bian
Zhangming Bian
LYLi Yu
Li Yu

21 April 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YXYanwu Xu
Yanwu Xu
ZZZhuoran Zhang
Zhuoran Zhang
ZBZhangming Bian
Zhangming Bian
LYLi Yu
Li Yu
A doubly salient electromagnetic starter/ generator (DSESG) system based on the bidirectional converter (BDC) is proposed. The BDC is operated as an inverter in starting mode and as an active rectifier (AR) in generation mode. Compared to the conventional DSESG system, which is based on an inverter and a diode rectifier or a discrete inverter/rectifier unit (IRU), the configuration is simplified and the weight is reduced. Since the output voltage is improved by the angular position control (APC), field and phase currents are re-distributed. The copper loss optimization control (CLOC) for the AR is proposed. The copper loss is analyzed based on the extreme learning machine (ELM) and the turn-off angles are selected. The copper loss is minimized and the heat is reduced. The copper loss and heat generation are also balanced in the field and phase windings to decrease the temperature of the field windings at low speed. Experimental verifications are conducted on a 9kW DSESG prototype. The effectiveness of the proposed ELM-based CLOC is verified by simulation and experiments. A lighter and simpler DSESG system with reduced loss is presented.

1 June 2020 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
YXYanwu Xu
Yanwu Xu
ZZZhuoran Zhang
Zhuoran Zhang
ZBZhangming Bian
Zhangming Bian
LYLi Yu
Li Yu
A DC-link voltage regulation method is proposed based on capacitor energy control (CEC) for the doubly salient electro-magnetic generator (DSEG) system. Instead of tracking the DC-link voltage, the stored energy in the DC-link capacitor is set as the control target in the outer loop. A proportional component that converts the command output current into the command field current is developed between the capacitor energy loop and field current loop. The coefficient in the proportional component is investigated based on the mathematical model of the 12-8 pole DSEG, considering the load and speed variation. The dynamic response of the DSEG system is accelerated and the DC-link voltage variation is reduced with the proposed method. Furthermore, the adaptability to speed variation of the controlled is optimized. Since the DC-link capacitance is an additional parameter, the influences of capacitor degradation are investigated. The conventional voltage control and the CEC are implemented and compared on a DSEG platform. The optimized performance of the proposed method is verified by both finite element analysis (FEA) and experiments. The proposed method provides optimized dynamic performance over the entire speed range, enabling the DSEG system as a competitive option in the aircraft application.

3 April 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
YXYanwu Xu
Yanwu Xu
ZZZhuoran Zhang
Zhuoran Zhang
With the rapid evolution of more electric aircraft (MEA) technology, the aviation industry has witnessed an enormous, continuing increase in the capacity of the onboard electric power system (EPS). The 270-/540-V high-voltage dc (HVdc) EPS has emerged as a highly promising candidate for MEA applications. The generator system serves as a vital core component of the onboard EPS, with the rectifier acting as its pivotal node. The efficiency and reliability of the rectifier considerably influence the performance of the EPS. This article presents a comprehensive review of generator rectification in MEA systems. The state of the art of aircraft dc generators is summarized. Topologies and control strategies of different rectifiers are analyzed and compared. The trends, challenges, and opportunities of MEA rectification are discussed. As a case study, a wound-field doubly salient generator (WFDSG) system is implemented. The diode rectifier, the active rectifiers based on angular position control (APC), and pulsewidth modulation (PWM) are compared. The output characteristics and the losses are analyzed, highlighting the differences in interactions between the generator and rectifier. Due to the higher output power, higher efficiency, and bidirectional characteristics, the APC active rectifier is a promising candidate in MEA WFDSG EPS.