Aurel Ercuta

Prof. Dr. Aurel Ercuta

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
AEAurel Ercuta
Aurel Ercuta
An induction hysteresigraph using 50 Hz sine wave fields of 7 kOe maximum amplitude, generated by a solenoid-type multilayer coil, suitable for small amounts (down to tens of mg) of magnetic materials is proposed. The changes in field and magnetization are detected by a field sensing coil, and by a compensated pick-up coil system, respectively, the as-induced signals being processed by two analog measuring channels (channel H and channel M), whose output signals reproduce the time evolution H(t) and M(t) of the two quantities. These signals are recorded via PC-assisted analog-to-digital conversion, and then subjected to final numerical correction and calibration; apart from the demagnetizing field correction, the possible errors caused by the stray flux generated by the magnetized sample itself are also taken into account. In addition, instead of weak signals denoising via standard filtering or smoothing algorithms, reconstruction based on flexible combinations of transition-type fitting functions of time periodic argument is proposed. To prevent signal waveform distortions which may be caused by the frequency-dependent response of channel M, a thorough analysis is carried out in the time domain, by simulating the run of a 100 kHz bandwidth severe test signal, across the stages of this channel. This signal consists of sharp ac pulses, built as a digital replica of the electromotive force induced in a pick-up coil containing the sample, during its evolution along a steep-sided hysteresis loop; an original method, using a small number of parameters, is proposed to build the spectral expansion of the test signal.

10 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
MDMircea Laurențiu Dan
Mircea Laurențiu Dan
Andrea KellenbergerAndrea Kellenberger
Andrea Kellenberger
DDDelia-Andrada Duca
Delia-Andrada Duca
NVNicolae Vaszilcsin
Nicolae Vaszilcsin
CCCorneliu Craciunescu
Corneliu Craciunescu
TKThulile Khoza
Thulile Khoza
Cost reduction in bipolar plates in proton exchange membrane water electrolyzers has previously been attempted by substituting bulk titanium with austenitic stainless steels protected with highly conductive and corrosion-resistant coatings. However, austenitic steels are more expensive than ferritic steels due to their high nickel content. Herein we report on the corrosion resistance of two high chromium ferritic stainless steels, AISI 442 and AISI 446, as an alternative material to manufacture bipolar plates. Electrochemical corrosion tests have shown that AISI 442 and AISI 446 have similar corrosion resistance, while AISI 446 reveals more noble corrosion potential and performs better during potentiostatic stress tests. The current density obtained during polarization at 2 V versus the standard hydrogen electrode (SHE) is 3.3 mA cm−2, which is more than two times lower than on AISI 442. Additionally, surface morphology characterization demonstrates that in contrast to AISI 442, AISI 446 is not sensitive to intercrystalline or pitting corrosion. Moreover, EDX energy dispersion analysis of AISI 446 reveals no differences in the chemical composition of the surface layer compared to the base material, as a confirmation of its high corrosion resistance. The results of this work open up the perspective of replacing austenitic stainless steels with less expensive ferritic stainless steels for the production of components such as bipolar plates in proton exchange membrane water electrolyzers.

17 March 2022 in Journal of Power Sources
Verified
Journal Article
Open access
SLSigrid Lædre
Sigrid Lædre
CCCorneliu Craciunescu
Corneliu Craciunescu
TKThulile Khoza
Thulile Khoza
NVNicolae Vaszilcsin
Nicolae Vaszilcsin
Andrea KellenbergerAndrea Kellenberger
Andrea Kellenberger
AEAurel Ercuta
Aurel Ercuta

24 December 2022 in Magnetochemistry
Verified
Journal Article
Open access
PDF file
IMIon Marius Chirita Mihaila
Ion Marius Chirita Mihaila
ABAdrian Bezergheanu
Adrian Bezergheanu
CCCorneliu Bazil Cizmas
Corneliu Bazil Cizmas
AEAurel Ercuta
Aurel Ercuta
Single-crystalline magnetite (Fe3O4) particles having a size beyond the nanometric range (1 µm to 50 µm) and showing high (close to the bulk value) saturation-specific magnetization (σs = 92 emu/g), were obtained by the hydrothermal decomposition of the Fe-EDTA complex. The very low values of the magnetic remanence (σr = 0.82 emu/g) and coercitivity (μoHc = 1.53 mT) observed at room temperature (RT) suggest a superparamagnetic-like behavior, which is quite remarkable for such micrometric magnetite particles. As confirmed by vibrating sample magnetometer (VSM)-based measurements, minor changes in their magnetic properties occur between RT and 5K. Scanning electron microscopy (SEM) has revealed a morphology consisting of a combination of non-porous octahedral- and dodecahedral-shaped particles, energy dispersive X-ray analysis (EDX) has indicated high elemental (Fe and O) purity, whereas X-ray diffraction (XRD) has confirmed a single crystal structure. The nitrogen adsorbtion–desorption isotherm and pore size distribution are presented for the magnetite sample. Thermomagnetic records under zero field-cooled (ZFC) and field-cooled (FC) conditions have revealed a thermal hysteresis of the Verwey transition.The Verwey point (TV) at which the major step of the phase transformation takes place is located around 132 K for heating and around 122 K for cooling. These microcrystals do not remain agglomerated when the polarizing field is removed, an essential requirement in biomedical applications is met.

10 November 2015 in Science and Technology of Advanced Materials
Verified
Journal Article
Open access
PDF file
CCCorneliu Craciunescu
Corneliu Craciunescu
AEAurel Ercuta
Aurel Ercuta
The effect of superposed transitions in actuators with layered shape memory alloy (SMA) films undergoing martensitic phase transformation is analyzed in terms of a model developed for two layers of different composition, deposited at the same temperature on a substrate. A significant difference is observed in the actuation versus temperature relationship, depending on the thermal and elastic properties of the SMA layers and their martensitic transformation temperature. The prediction of the actuation is exemplified using a multilayer model and is verified for a cantilever actuator with NiTi and NiMnGa layers deposited on a Si substrate. The model sets the ground for a smart selection of SMAs in order to achieve a modulated actuation.

31 December 2018 in Studia Universitatis Babeș-Bolyai Chemia
Verified
Journal Article
Open access
R(Roxana Nicola (Crişan)
Roxana Nicola (Crişan)
OCOtilia Costisor
Otilia Costisor
Ianasi CatalinIanasi Catalin
Ianasi Catalin
RLRadu Lazau
Radu Lazau
LSLiviu Sacarescu
Liviu Sacarescu
CSCecilia Savii
Cecilia Savii
Two series of magnetic nanopowders were synthesized at room temperature starting from a mixture of iron II and III precursors, FeSO4 and FeCl3, respectively. Precipitation agents, as KOH and NaOH were used. While the concentration of the added ferrous and ferric solutions ranged between 0.1 M and 0.0125 M, the hydroxide solution concentration was maintained constant (1 M). TEM images of the samples showed that the particles shape changes from quasi spherical to spherical. For both series the crystallite size decreases with iron concentration, from 9 to 2 nm for KOH series and from 10 to 3 nm for NaOH series. Moessbauer Spectroscopy was signaling only Fe3+ in the final spinel product. BET measurements revealed the material mesoporosity and fractal structure of maghemite nanoparticles that explain the unusual high surface area, ~240 m2/g. All the samples actually exhibit superparamagnetic behavior at room temperature with saturation magnetization up to 73 emu/g value closed to those of bulk maghemite.