Zhixin Zhou

Mr. Zhixin Zhou


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
HWHui Wang
Hui Wang
LZLinwei Zhang
Linwei Zhang
ZZZhixin Zhou
Zhixin Zhou
LLLiang Lou
Liang Lou
In this paper, the temperature performance of AlN-SAW resonators and AlScN-SAW resonators is studied. They are simulated by COMSOL Multiphysics, and their modes and the S11 curve are analyzed. The two devices were fabricated using MEMS technology and tested using VNA, and the test results were consistent with the simulation results. Temperature experiments were carried out with temperature control equipment. With the change in temperature, the changes in S11 parameters, TCF coefficient, phase velocity, and quality factor Q were analyzed. The results show that the temperature performance of the AlN-SAW resonator and the AlScN-SAW resonator is very good, and both have good linearity. At the same time, the sensitivity of the AlScN-SAW resonator is greater by 9.5%, the linearity is greater by 15%, and the TCF coefficient is greater by 11.1%. The temperature performance is excellent, and it is more suitable as a temperature sensor.

6 May 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
LJli junxiang
li junxiang
YGYunfei Gao
Yunfei Gao
ZZZhixin Zhou
Zhixin Zhou
QPQiang Ping
Qiang Ping
LQLei Qiu
Lei Qiu
LLLiang Lou
Liang Lou
Ultrasonic wireless power transfer technology (UWPT) represents a key technology employed for energizing implantable medical devices (IMDs). In recent years, aluminum nitride (AlN) has gained significant attention due to its biocompatibility and compatibility with complementary metal-oxide-semiconductor (CMOS) technology. In the meantime, the integration of scandium-doped aluminum nitride (Al90.4%Sc9.6%N) is an effective solution to address the sensitivity limitations of AlN material for both receiving and transmission capabilities. This study focuses on developing a miniaturized UWPT receiver device based on AlScN piezoelectric micro-electromechanical transducers (PMUTs). The proposed receiver features a PMUT array of 2.8 × 2.8 mm2 comprising 13 × 13 square elements. An acoustic matching gel is applied to address acoustic impedance mismatch when operating in liquid environments. Experimental evaluations in deionized water demonstrated that the power transfer efficiency (PTE) is up to 2.33%. The back-end signal processing circuitry includes voltage-doubling rectification, energy storage, and voltage regulation conversion sections, which effectively transform the generated AC signal into a stable 3.3 V DC voltage output and successfully light a commercial LED. This research extends the scope of wireless charging applications and paves the way for further device miniaturization by integrating all system components into a single chip in future implementations.

23 February 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
JYJiawei Yin
Jiawei Yin
ZZZhixin Zhou
Zhixin Zhou
LLLiang Lou
Liang Lou
Ultrasonic nondestructive testing (NDT) usually utilizes conventional bulk piezoelectric transducers as transceivers. However, the complicated preparation and assembly process of bulk piezoelectric ceramics limits the development of NDT probes toward miniaturization and high frequency. In this paper, a 4.4 mm × 4.4 mm aluminum nitride (AlN) piezoelectric micromachined ultrasonic transducer (PMUT) array is designed, fabricated, characterized, and packaged for ultrasonic pulse–echo NDT of solids for the first time. The PMUT array is prepared based on the cavity silicon-on-insulator (CSOI) process and packaged using polyurethane (PU) material with acoustic properties similar to water. The fabricated PMUT array resonates at 2.183 MHz in air and at around 1.25 MHz after PU encapsulation. The bandwidth of the packaged PMUT receiver (244 kHz) is wider than that of a bulk piezoelectric transducer (179 kHz), which is good for axis resolution improvement. In this work, a hybrid ultrasonic NDT probe is designed using two packaged PMUT receivers and one 1.25 MHz bulk transmitter. The bulk transmitter radiates an ultrasonic wave into the sample, and the defect echo is received by two PMUT receivers. The 2D position of the defect could be figured out by time-of-flight (TOF) difference, and a 30 mm × 65 mm detection area is acquired. This work demonstrates the feasibility of applying AlN PMUTs to ultrasonic NDT of solids and paves the way toward a miniaturized NDT probe using AlN PMUT technology.

25 April 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
HLHl L
Hl L
ZZZhixin Zhou
Zhixin Zhou
LLLiang Lou
Liang Lou
In this paper, we propose a novel method for temperature measurement using surface acoustic wave (SAW) temperature sensors on curved or irregular surfaces. We integrate SAW resonators onto flexible printed circuit boards (FPCBs) to ensure better conformity of the temperature sensor with the surface of the object under test. Compared to traditional rigid PCBs, FPCBs offer greater dynamic flexibility, lighter weight, and thinner thickness, which make them an ideal choice for making SAW devices working for temperature measurements under curved surfaces. We design a temperature sensor array consisting of three devices with different operating frequencies to measure the temperature at multiple points on the surface of the object. To distinguish between different target points in the sensor array, each sensor operates at a different frequency, and the operating frequency bands do not overlap. This differentiation is achieved using Frequency Division Multiple Access (FDMA) technology. Experimental results indicate that the frequency temperature coefficients of these sensors are −30.248 ppm/°C, −30.195 ppm/°C, and −30.115 ppm/°C, respectively. In addition, the sensor array enables wireless communication via antenna and transceiver circuits. This innovation heralds enhanced adaptability and applicability for SAW temperature sensor applications.

18 April 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
ZZZhixin Zhou
Zhixin Zhou
HWHui Wang
Hui Wang
LLLiang Lou
Liang Lou
The surface acoustic wave (SAW) temperature sensor has received significant attention due to its wirelessly powered, battery-free, and chipless capabilities. This paper proposes a wireless sensing system comprising a one-port SAW resonator, helix antenna, and transceiver circuit. The SAW resonator used in this system is based on aluminum nitride (AlN) thin film, which exhibits high velocity and excellent piezoelectric properties. Simulations and experiments were conducted to investigate the performance of the designed SAW resonator. A helix antenna was also designed using finite element simulation to facilitate signal transmission between the SAW temperature sensor and the transceiver. An impedance-matching network was introduced between the helix antenna and the SAW resonator to optimize signal transmission. When the wireless SAW temperature sensor was placed within a certain distance of the mother antenna, the reflection peak of the SAW resonator was observed in the spectrum of the return signal. The frequency of the echo signal increased almost linearly as the temperature increased during the temperature tests. The fitted temperature coefficient of frequency (TCF) was −31.34 ppm/°C, indicating that the wireless temperature sensing system has high-temperature sensitivity.