Rock particles in excavated materials can damage and wear down slurry discharge pipelines when slurry shield tunneling occurs in a pebble layer and rock ground. This pipeline damage and wear, if not properly dealt with, can lead to a broken-down tunneling machine. Based on a slurry shield tunneling project in China, damage and wear were thoroughly examined. The observed pipeline wear and leaks, transported rock particles, mechanical properties, and flow rate of the carrier slurry were presented. The measured results showed that the wear rates of a straight pipe, a pipe along a curved tunnel, a 60° inclined pipe, and a 90° elbow pipe in pebble ground were approximately 0.71 mm/100 rings, 1 mm/100 rings, 2.14 mm/100 rings, and 4 mm/100 rings, respectively. When the machine drove into rock ground, the wear rates increased by one to two times, which could be attributed to the sharper particle shapes. Countermeasures to address these issues, such as adjusting the pipeline layout, welding reinforcement plates in advance, and preparing additional pipes, were highlighted. The wear rates of different types of pipes, the effectiveness of new pipeline fixing methods, and the probability of pipeline leaks in different strata were discussed in detail.
When a slurry TBM advances in pebble and rock strata, large rock particles are carried in pipelines out of a tunnel by moving slurry. To estimate the wear of horizontally straight slurry discharge pipes, a phenomenological model was proposed that was mainly based on knowledge gained by means of direct and indirect in situ observations. The proposed model applies an equation composed of three variables, namely, the wear rate (λ), the central angle (2α), and the excavated tunnel length (L), to estimate the wear distribution along a pipe’s internal surface. The results indicated that wear mainly occurred on the bottoms of pipes. In addition, linear relationships between the maximum pipe wear amount (δmax) and the excavated tunnel length (L) were found for specific pipes and specified types of ground. The observed wear rates of different pipes in different types of ground had varied constants. The wear rates were higher for pipes in rock ground than for those in a pebble layer. For horizontally straight pipes, the observed wear rates were 0.0045 mm/m in a pebble layer and 0.0212 mm/m in rock ground. Lastly, to improve the proposed model, more field monitoring will be necessary to determine the pipe wear rates in different types of ground in the future.
During slurry shield tunneling in hard rock or cobble strata, the discharge pipes suffer serve wear and damage. However, the effect mechanism of pipe wall wear defects on the flow characteristics of two-phase flow is unclear. In this study, a three-dimensional slurry particle model of pipeline transport was established using the coupled computational fluid dynamics–discrete element method (CFD-DEM) considering the pipe wall wear defect, and the typical pipeline forms of straight pipe and 90° elbow pipe were selected as the research targets. The results indicated that the localized wear defect of pipes can lead to increased inhomogeneity in the velocity distribution, generating localized low-flow zones and resulting in a reduced flow rate or stagnancy in parts of the pipe. Meanwhile, the wear defect of the pipe results in local shape changes, so that the fluid flow path through the pipe is no longer smooth, causing more vortex/turbulence and secondary flow, where an increased vortex promotes localized kinetic energy reduction and creates larger pressure losses at the elbow. In addition, for the elbow pipe without wear defect, the pressure drop of the elbow increases quadratically from an increase of 6.5% to an increase of 16.9%, with the maximum wear depth increasing from 4 mm to 19 mm. For the straight pipe without wear defect, the pressure drop of the elbow increases linearly, from an increase of 2.2% to an increase of 10.2% with the maximum wear depth increasing from 4 mm to 19 mm. The paper investigates the potential mechanism of pipe flow characteristics influenced by wear defect and provides practical guidelines for the efficient operation of a slurry shield circulating system.