Maria Kaftaranova

Mrs. Maria Kaftaranova


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Sergey AnikeevSergey Anikeev
Sergey Anikeev
MKMaria Kaftaranova
Maria Kaftaranova
VHValentina Hodorenko
Valentina Hodorenko
SIStanislav Ivanov
Stanislav Ivanov
NANadezda Victorovna Artyukhova
Nadezda Victorovna Artyukhova
VGVictor E. Gunther
Victor E. Gunther
Alloys based on TiNi are widely used in various fields of technology and medicine. In the present work, we report on the preparation of TiNi-alloy-based wire with the shape-memory effect, which was used for compression clips for surgery. The composition and structure of the wire and its martensitic and physical–chemical properties were studied using SEM, TEM, optic microscopy, profilometry, mechanical tests, etc. The TiNi alloy was found to consist of B2 and B19′ and secondary-phase particles of Ti2Ni, TiNi3 and Ti3Ni4. Its matrix was slightly enriched in Ni (50.3 at.% of Ni). A homogeneous grain structure was revealed (an average grain size of 19 ± 0.3 μm) with equal quantities of grain boundaries of special and general types. The surface oxide layer provides improved biocompatibility and promotes the adhesion of protein molecules. Overall, the obtained TiNi wire was concluded to exhibit martensitic, physical and mechanical properties suitable for its use as an implant material. The wire was then used for manufacturing compression clips with the shape-memory effect and applied in surgery. The medical experiment that involved 46 children demonstrated that the use of such clips in children with double-barreled enterostomies permitted improvement in the results of surgical treatment.

11 October 2022 in Metals
Verified
Journal Article
Open access
PDF file
MKMaria Kaftaranova
Maria Kaftaranova
VHValentina Hodorenko
Valentina Hodorenko
Sergey AnikeevSergey Anikeev
Sergey Anikeev
NANadezda Victorovna Artyukhova
Nadezda Victorovna Artyukhova
ASAnastasiia Shabalina
Anastasiia Shabalina
VGVictor Gunther
Victor Gunther
This work is devoted to the physical and mechanical properties of porous alloys based on TiNi alloyed with different amounts of Cu additive. We show that by doping a porous TiNi alloy with copper instead of nickel, it is possible to obtain characteristics acceptable for use in implantology and superior to those of known porous TiNi alloys. Cu addition in the range from 1 to 10 at.% is shown to optimize the properties of tested alloys. There is a decrease in the minimal martensitic transformation stress τMsmin from 37 to 17 MPa when compared to initial unalloyed TiNi. Alloys with 3 and 6 at.% of Cu are found to be optimal for use in medical practice. Along with a wide temperature range of reversible deformations that cover the range of operating temperatures (273–313 K), such alloys demonstrate their martensitic transformation stress values below 28 MPs. This permits to model implantable structures of complex configuration from such materials under a certain temperature regime.

Verified
Journal Article
Open access
PDF file
ASAnastasiia Shabalina
Anastasiia Shabalina
Sergey AnikeevSergey Anikeev
Sergey Anikeev
Sergei KulinichSergei Kulinich
Sergei Kulinich
NANadezda Victorovna Artyukhova
Nadezda Victorovna Artyukhova
VVVitaly Vlasov
Vitaly Vlasov
VGVictor E. Gunther
Victor E. Gunther
TiNi alloys are very widely used materials in implant fabrication. When applied in rib replacement, they are required to be manufactured as combined porous-monolithic structures, ideally with a thin, porous part well-adhered to its monolithic substrate. Additionally, good biocompatibility, high corrosion resistance and mechanical durability are also highly demanded. So far, all these parameters have not been achieved in one material, which is why an active search in the field is still underway. In the present study, we prepared new porous-monolithic TiNi materials by sintering a TiNi powder (0–100 µm) on monolithic TiNi plates, followed by surface modification with a high-current pulsed electron beam. The obtained materials were evaluated by a set of surface and phase analysis methods, after which their corrosion resistance and biocompatibility (hemolysis, cytotoxicity, and cell viability) were evaluated. Finally, cell growth tests were conducted. In comparison with flat TiNi monoliths, the newly developed materials were found to have better corrosion resistance, also demonstrating good biocompatibility and potential for cell growth on their surface. Thus, the newly developed porous-on-monolith TiNi materials with different surface porosity and morphology showed promise as potential new-generation implants for use in rib endoprostheses.

11 July 2019 in Russian Physics Journal
Verified
Journal Article
Closed access
PDF file
NANadezda Victorovna Artyukhova
Nadezda Victorovna Artyukhova
MKMaria Kaftaranova
Maria Kaftaranova
Sergey AnikeevSergey Anikeev
Sergey Anikeev
VKV. N. Khodorenko
V. N. Khodorenko
AGA. S. Garin
A. S. Garin
VGV. É. Gunther
V. É. Gunther

14 July 2020 in Russian Physics Journal
Verified
Journal Article
Closed access
PDF file
Sergey AnikeevSergey Anikeev
Sergey Anikeev
NANadezda Victorovna Artyukhova
Nadezda Victorovna Artyukhova
VHValentina Hodorenko
Valentina Hodorenko
MKMaria Kaftaranova
Maria Kaftaranova
EYEvgeny Yakovlev
Evgeny Yakovlev
VGV. E. Gunther
V. E. Gunther

1 March 2019 in Izvestiya vysshikh uchebnykh zavedenii. Fizika
Verified
Journal Article
Closed access
NANadezda Victorovna Artyukhova
Nadezda Victorovna Artyukhova
MKMaria Kaftaranova
Maria Kaftaranova
Sergey AnikeevSergey Anikeev
Sergey Anikeev
VKV.N. Khodorenko
V.N. Khodorenko
AGA.N. Garin
A.N. Garin
VGV.E. Gunther
V.E. Gunther