Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate (r = 0.95), respiratory rate (r = 0.93) and respiratory volume (r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.
10 October 2022 in IEEE Transactions on Biomedical Engineering
Objective: Respiratory disturbances during sleep are a prevalent health condition that affects a large adult population. The gold standard to evaluate sleep disorders including apnea is overnight polysomnography, which requires a trained technician for live monitoring and post-processing scoring. Currently, the disorder events can hardly be predicted using the respiratory waveforms preceding the events. The objective of this paper is to develop an autonomous system to detect and predict respiratory events reliably based on real-time covert sensing. Methods : A bed-integrated radio-frequency (RF) sensor by near-field coherent sensing (NCS) was employed to retrieve continuous respiratory waveforms without user's awareness. Overnight recordings were collected from 27 patients in the Weill Cornell Center for Sleep Medicine. We extracted respiratory features to feed into the random-forest machine learning model for disorder detection and prediction. The technician annotation, derived from observation by polysomnography, was used as the ground truth during the supervised learning. Results : Apneic event detection achieved a sensitivity and specificity up to 88.6% and 89.0% for k -fold validation, and 83.1% and 91.6% for subject-independent validation. Prediction of forthcoming apneic events could be made up to 90 s in advance. Apneic event prediction achieved a sensitivity and specificity up to 81.3% and 82.1% for k -fold validation, and 80.5% and 82.4% for subject-independent validation. The most important features for event detection and prediction can be assessed in the learning model. Conclusion : A bed-integrated RF sensor can covertly and reliably detect and predict apneic events. Significance : Predictive warning of the sleep disorders in advance can intervene serious apnea, especially for infants, servicemen, and patients with chronic conditions.
Many prevalent heart diseases can be indicated by the features of the jugular venous pulse (JVP), an efficacious indicator of right heart health. However, JVP dynamics are not widely utilized in clinical settings, as its observation and sensing remain cumbersome. Noninvasive measures of cardiac behavior, including the JVP, are of growing interest to enable continuous and at-home monitoring of cardiac disorders. In this work, we propose a wearable near-field radio frequency (RF) sensor affixed with a neck collar on the clavicle over the internal jugular vein (IJV) to enable noninvasive JVP sensing. We employed a complex vector injection signal processing method to extract repeatable JVP waveform features in multiple postures. With a 21-subject human study, we demonstrated morphologically consistent JVP sensing with consistent a-, c-, and v-wave feature timings, benchmarked by synchronous electrocardiogram (ECG) and phonocardiogram (PCG). Furthermore, inter-postural experiments demonstrated the capability of the proposed system to quantify morphological changes to the JVP, which are present in many cardiac disorders. The results of this work suggest that the proposed near-field RF sensor is capable of noninvasive JVP monitoring, potentially enabling improved sensing in both clinical and ambulatory environments.
26 August 2022 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Near-field radio-frequency(RF) sensing can realize wearable touchless vital-sign sensors with touchless and flexible deployment. By placing a transmitter (Tx) antenna in the near-field region of dielectric boundary motion, both the magnitude and phase of the Tx signal will be modulated and be recorded as a complex signal at the receiver (Rx). Direct-path interference (DPI) from Tx to Rx without motion modulation often dominates and can vary due to different environmental factors and initial transceiver conditions, which can lead to inconsistent waveform morphology of the magnitude and phase at Rx, sometimes even yielding low signal quality or phase reversal. Here we proposed a complex vector injection (CVI) method, which adds a constant complex phasor to the Rx quadrature signal to regularize the waveform morphology selectively. To demonstrate the effectiveness of the CVI algorithm, we designed a torso phantom for sensor benchmarking. By using different objective functions to select the optimal injection vector, we can enhance different features in the real-number waveform. Furthermore, we applied the algorithm in the study of 21 human subjects for heartbeat monitoring, and showed that we could effectively enhance the signal quality and regularize the waveform morphology which is critical for time-domain feature recognition in physiological and pathological studies.
Near-field radio sensors can be implemented both as wearables for continuous monitoring and as furnishing attachments for covert operation, without requiring skin touch, enabling convenient deployment and high user comfort. The sensor can output cardiac and respiratory waveforms, systemic pulses, muscle contraction, eye movement, and tissue vibration for various biomedical, biological, and cyberphysical applications. The radio signal can go through layers of fabrics or animal surface coverings with little loss or dispersion to couple directly inside the living body. We will illustrate the theory, design variations, and verified results, and discuss present limitations and outlooks for technology adoption in practical scenarios.
6 December 2022 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Biometric identification (ID) has become increasingly prevalent in the digital era. Static biometric methods, such as fingerprint and facial recognition are widely accepted, yet generally vulnerable to targeted presentation attacks. Current development has expanded to dynamic biometrics, such as gait and electrocardiogram, that enable continuous authentication and are significantly more resistant to presentation attacks. However, dynamic biometrics often involve cumbersome acquisition which restricts their widespread use. Here, we introduce Heart ID, a novel dynamic biometric system that uses near-field coherent sensing (NCS) with a multiple-in multiple-out (MIMO) radio-frequency (RF) antenna setup to non-invasively acquire detailed recordings of internal cardiac dielectric boundary motion over clothing. NCS couples localized energy to the heart to derive interpersonal structural differences, while MIMO significantly increases the biometric entropy compared to single-point observation. We performed a human study of 20 subjects as well as 2 longitudinal evaluations, and employed an unsupervised feature extraction method to explore the ID performance of this new biometric. We found an ensemble classification approach using features derived from unsupervised learning can achieve accuracy exceeding 99% at a 40-second epoch.