Huaitao Song

Dr. Huaitao Song

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LSLi Sen
Li Sen
CFChunyong Feng
Chunyong Feng
YNYunchen Niu
Yunchen Niu
LSLong Shi
Long Shi
ZWZeqi Wu
Zeqi Wu
HSHuaitao Song
Huaitao Song
Due to hot toxic smoke and unknown risks under fire conditions, detection and relevant reconnaissance are significant in avoiding casualties. A fire reconnaissance robot was therefore developed to assist in the problem by offering important fire information to fire fighters. The robot consists of three main systems, a display operating system, video surveillance, and mapping and positioning navigation. Augmented reality (AR) goggle technology with a display operating system was also developed to free fire fighters’ hands, which enables them to focus on rescuing processes and not system operation. Considering smoke disturbance, a thermal imaging video surveillance system was included to extract information from the complicated fire conditions. Meanwhile, a simultaneous localization and mapping (SLAM) technology was adopted to build the map, together with the help of a mapping and positioning navigation system. This can provide a real-time map under the rapidly changing fire conditions to guide the fire fighters to the fire sources or the trapped occupants. Based on our experiments, it was found that all the tested system components work quite well under the fire conditions, while the video surveillance system produces clear images under dense smoke and a high-temperature environment; SLAM shows a high accuracy with an average error of less than 3.43%; the positioning accuracy error is 0.31 m; and the maximum error for the navigation system is 3.48%. The developed fire reconnaissance robot can provide a practically important platform to improve fire rescue efficiency to reduce the fire casualties of fire fighters.

25 January 2022 in Energy and Buildings
Verified
Journal Article
Closed access
HSHuaitao Song
Huaitao Song
QCQianlong Chen
Qianlong Chen

15 June 2023 in Fire
Verified
Journal Article
Open access
PDF file
HSHuaitao Song
Huaitao Song
HYHao-wei YAO
Hao-wei YAO
XWXiaoge Wei
Xiaoge Wei
HQHengjie Qin
Hengjie Qin
YLYouxin Li
Youxin Li
QCQianlong Chen
Qianlong Chen
Fire accidents due to oil-immersed transformers seriously threaten the safe operation of power systems. In this paper, the similarity principle was used to design a high-pressure water mist fire-extinguishing test platform for a small-scale transformer fire, and the design method achieved a good fire extinguishing effect. The results indicate that a deflagration phenomenon, lasting about 2–4 s, could be observed after activating the high-pressure water mist system; the flame temperature rose rapidly at first, then dropped sharply, and finally cooled to the indoor temperature. The nozzle’s flow rate in this system has a significant impact on the fire extinguishing time. Meanwhile, the adjustment of the upper nozzle height also influenced the fire suppression effectiveness of the system, where a height of 1800 mm achieved the best performance compared to the others. In addition, the ambient wind speed is a very unfavorable factor for transformer fire suppression, where the fire extinguishing efficiency decreases rapidly with the increase in wind speed. Therefore, under low wind speed conditions, the high-pressure water mist system has great advantages in the fire suppression of outdoor oil-immersed transformers, and the above research results can provide a reference for the optimization design of this system.

23 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HSHuaitao Song
Huaitao Song
JLJingfen Li
Jingfen Li
YYyueyang yu
yueyang yu
QCQianlong Chen
Qianlong Chen
With the long-term running of the subway, the soil layer around the tunnel takes on the thermal deposition effect, which can lead the air in the tunnel to heat up and pose a serious threat to the safety operation of trains. Through taking some subway tunnels from typical zones as an example, the influence of tunnel depth on the heat storage characteristics of the surrounding soil mass was analyzed in the paper. The results indicate that the temperature field of the surrounding soil mass was thermally disturbed by both the ground air temperature and the tunnel air temperature, and there was a significant coupling point ‘O’ located at the center of the tunnel overburden. With the extension of the heat-exchange time, the shape of the cooling ring around the tunnel gradually changed from a circle to an oval. For the analysis of cases, from the space aspect, when the tunnel depth was less than 30 m, the wall temperature increased gradually with the increase of tunnel depth. From the time aspect, over time, the wall temperature gradually rose and finally reached a fixed value. From the region aspect, the heat absorption capacity of different areas decreased gradually with the increase of tunnel depth. When the depth exceeded 45 m, the heat absorption capacity of certain cities became negative. In addition, three typical boundaries were discussed, and the optimal method for evaluating the heat absorption capacity of the tunnel soil was ultimately determined. This study has important reference value for temperature control and positioning problems in the process of tunnel construction and operation.

26 October 2024 in Fire
Verified
Journal Article
Open access
PDF file
HSHuaitao Song
Huaitao Song
YSYali Shi
Yali Shi
HYHao-wei YAO
Hao-wei YAO
XWXiaoge Wei
Xiaoge Wei
HQHengjie Qin
Hengjie Qin
YYyueyang yu
yueyang yu
In order to study the influence of wind direction on fire spread on building facades, a three-dimensional model of a high-rise building was built with PyroSim software. Numerical simulations were conducted with five wind directions (0°, 45°, 90°, 135° and 180°) and a reference wind speed of 3 m/s. The results show that the fire spread on the building facade was most significant on the leeward side, followed by the upwind condition. The horizontal spread of fire was promoted by crosswinds at 45°, 90° and 135°, while its vertical spread was inhibited. Among these, the inhibitory effect of the 45° crosswind was the greatest. The fire spread area under the leeward condition was the greatest at approximately 341.3 m2, accounting for 17.1% of the facade, and the vertical spread velocity under the condition of no wind was the fastest at 0.075 m/s. In this study, the motion characteristics of facade fire spread under different wind directions were determined, providing supporting evidence to enhance fire safety prevention and control measures in high-rise buildings.

25 May 2024 in Fire
Verified
Journal Article
Open access
PDF file
HYHao-wei YAO
Hao-wei YAO
MXMengyang xing
Mengyang xing
HSHuaitao Song
Huaitao Song
YZYang Zhang
Yang Zhang
SLSheng Luo
Sheng Luo
ZBZ. P. BAI
Z. P. BAI
Once a fire breaks out in an electric bus, it can easily lead to mass casualties and severe injuries, resulting in significant property damage and social impact. The high-temperature smoke and toxic gases in an electric bus fire are key factors that cause a large number of casualties, both of which are closely related to ventilation conditions. In view of this, this study utilized the Fire Dynamics Simulator (FDS 6) software to establish a three-dimensional experimental model of an electric bus. Numerical simulations of the fire combustion process in the electric bus under different ventilation conditions were conducted. Multiple fire scenes were established based on varying ventilation areas, different wind speeds, and diverse window opening positions. This study specifically analyzed the temperature and CO concentration variations under different fire scenes. By comparing the simulation results under different ventilation conditions, it can be concluded that when an electric bus catches fire, opening 100% of the windows, the wind speed is 8 m/s, and opening the rear window of the electric bus first can minimize the fire risk. Through the numerical simulation of electric bus fires under various conditions, this study analyzed the impact of different ventilation conditions on electric bus fires, providing a theoretical basis for firefighting and rescue efforts as well as personnel evacuation in electric bus fire incidents, with the ultimate goal of maximizing public safety.