yueyang yu

Mr. yueyang yu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2024 in Fire
Verified
Journal Article
Open access
PDF file
HSHuaitao Song
Huaitao Song
YSYali Shi
Yali Shi
HYHao-wei YAO
Hao-wei YAO
XWXiaoge Wei
Xiaoge Wei
HQHengjie Qin
Hengjie Qin
YYyueyang yu
yueyang yu
In order to study the influence of wind direction on fire spread on building facades, a three-dimensional model of a high-rise building was built with PyroSim software. Numerical simulations were conducted with five wind directions (0°, 45°, 90°, 135° and 180°) and a reference wind speed of 3 m/s. The results show that the fire spread on the building facade was most significant on the leeward side, followed by the upwind condition. The horizontal spread of fire was promoted by crosswinds at 45°, 90° and 135°, while its vertical spread was inhibited. Among these, the inhibitory effect of the 45° crosswind was the greatest. The fire spread area under the leeward condition was the greatest at approximately 341.3 m2, accounting for 17.1% of the facade, and the vertical spread velocity under the condition of no wind was the fastest at 0.075 m/s. In this study, the motion characteristics of facade fire spread under different wind directions were determined, providing supporting evidence to enhance fire safety prevention and control measures in high-rise buildings.

23 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HSHuaitao Song
Huaitao Song
JLJingfen Li
Jingfen Li
YYyueyang yu
yueyang yu
QCQianlong Chen
Qianlong Chen
With the long-term running of the subway, the soil layer around the tunnel takes on the thermal deposition effect, which can lead the air in the tunnel to heat up and pose a serious threat to the safety operation of trains. Through taking some subway tunnels from typical zones as an example, the influence of tunnel depth on the heat storage characteristics of the surrounding soil mass was analyzed in the paper. The results indicate that the temperature field of the surrounding soil mass was thermally disturbed by both the ground air temperature and the tunnel air temperature, and there was a significant coupling point ‘O’ located at the center of the tunnel overburden. With the extension of the heat-exchange time, the shape of the cooling ring around the tunnel gradually changed from a circle to an oval. For the analysis of cases, from the space aspect, when the tunnel depth was less than 30 m, the wall temperature increased gradually with the increase of tunnel depth. From the time aspect, over time, the wall temperature gradually rose and finally reached a fixed value. From the region aspect, the heat absorption capacity of different areas decreased gradually with the increase of tunnel depth. When the depth exceeded 45 m, the heat absorption capacity of certain cities became negative. In addition, three typical boundaries were discussed, and the optimal method for evaluating the heat absorption capacity of the tunnel soil was ultimately determined. This study has important reference value for temperature control and positioning problems in the process of tunnel construction and operation.

23 November 2023 in Fire
Verified
Journal Article
Open access
PDF file
HSHuaitao Song
Huaitao Song
QCQianlong Chen
Qianlong Chen
ZWZeqi Wu
Zeqi Wu
HYHao-wei YAO
Hao-wei YAO
ZLZhen Lou
Zhen Lou
YYyueyang yu
yueyang yu
This paper investigates the sensitivity of factors influencing the transport of smoke in subway station fires by developing a three-dimensional physical model of a subway station using Building Information Modeling (BIM) technology and importing it into Fire Dynamics Simulator (FDS) software for numerical simulation. The orthogonal test method analyzes the effects of four common factors on temperature, CO concentration, and visibility. These factors are the mode of opening the screen door, the number of smoke vents opened, the number of smoke barriers, and the wind speed of the smoke vents. The results show that the smoke control system and the building structure influence smoke transport in subway stations, while the temperature and CO concentration gradually decrease as the distance from the fire source increases. In addition, the mode of opening the screen door is the most significant factor influencing temperature, CO concentration, and visibility using range and variance analysis. Moreover, the sensitivity analysis indicates that the optimal combination of all factors can significantly enhance the smoke exhaust efficiency. Compared with the average, the temperature optimal combination increases the smoke exhaust efficiency by 20.8%, CO concentration by 56.59%, and visibility by about 13.41%. This study provides a foundation for optimizing smoke control systems and formulating personnel evacuation strategies in subway stations.