Z. P. BAI

Dr. Z. P. BAI


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
HLHuaizhou Li
Huaizhou Li
WSwang shuaijun
wang shuaijun
ZBZ. P. BAI
Z. P. BAI
HWHong Wang
Hong Wang
LSLi Sen
Li Sen
SWShupei Wen
Shupei Wen
Thermal infrared imaging is less affected by lighting conditions and smoke compared to visible light imaging. However, thermal infrared images often have lower resolution and lack rich texture details, making them unsuitable for stereo matching and 3D reconstruction. To enhance the quality of infrared stereo imaging, we propose an advanced stereo matching algorithm. Firstly, the images undergo preprocessing using a non-local mean noise reduction algorithm to remove thermal noise and achieve a smoother result. Subsequently, we perform camera calibration using a custom-made chessboard calibration board and Zhang’s camera calibration method to obtain accurate camera parameters. Finally, the disparity map is generated using the SGBM (semi-global block matching) algorithm based on the weighted least squares method, enabling the 3D point cloud reconstruction of the object. The experimental results demonstrate that the proposed algorithm performs well in objects with sufficient thermal contrast and relatively simple scenes. The proposed algorithm reduces the average error value by 10.9 mm and the absolute value of the average error by 1.07% when compared with the traditional SGBM algorithm, resulting in improved stereo matching accuracy for thermal infrared imaging. While ensuring accuracy, our proposed algorithm achieves the stereo reconstruction of the object with a good visual effect, thereby holding high practical value.

22 January 2024 in Heliyon
Verified
Journal Article
Open access
ZBZ. P. BAI
Z. P. BAI
Power cables consist of insulation, padding and sheathing, which are highly susceptible to ignition. Power cables are an important factor affecting fire risk in urban utility tunnels (UUTs). In this paper, the combustion characteristics of four types of power cables (YJV, ZR-YJV, ZR-VV, and ZR-PE) in UUTs were investigated using a cone calorimeter. In this paper, laboratory experiments were conducted to investigate the combustion characteristics of power cables with two different parameters including two heat fluxes (35 kW/m2 and 75 kW/m2) and two sheath thicknesses (3 mm and 5 mm). The effects of heat release rate (HRR), effective heat combustion (EHC), optical density index (ODI) and smoke production rate (SPR) on ignition and combustion were investigated. The results showed that ZR-VV power cables have lower TTI, lower average HRR, lower EHC, higher MLR, and lower SEA than YJV and ZR-YJV power cables.With a conical calorimeter and heat flux of 35 kW/m2, the HRR of the power cables increased within 200 s, while for ODI, the total smoke output of ZR-YJV cables was minimized. Heat flux has a significant effect on HRR, SPR and EHC of ZR-PE cable. Sheath thickness has little effect on HRR, SPR and EHC of ZR-PE cables. In addition, one of the most important parameters, the ignition time, which depends on the composition and structure of the cable, was identified. Finally, the effect of external heat flux is complex and depends on the combustion characteristics of the power cable. Laboratory tests provide useful information for understanding the combustion behavior of power cables, including heat release rate, effective thermal burn, optical density index, and smoke production.

27 November 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ZBZ. P. BAI
Z. P. BAI
YLY. F. Li
Y. F. Li
YZY. H. Zhao
Y. H. Zhao
The overflow of the flame plume from the window is the main cause of the vertical spread of the fire on the facade of the building. This paper considers the geometry of the window by taking measures to prevent the flame from propagating along the vertical wall. In this paper, a residential building is taken as an example to evaluate the flame plume characteristics through experimental tests and numerical simulations. The objective of the present study is to study the flame plume characteristics under the air blow on the outer window side of the building. The theoretical equations of the flame tilt angle, non-dimensional temperature and non-dimensional velocity are derived. A series of experimental tests were carried out in a reduced-scale building model corresponding to the changes of lateral blow ventilation velocity. Reduced scale numerical simulations were conducted to verify the experiments. Results showed that the flame tilt angle increases with ventilation velocity increases. Meanwhile, the experimental results were compared with the reduced-scale tests and numerical simulations. These showed a good agreement between experimental results and numerical simulations. All these findings provide theoretical basis for building fire prevention outside window.

8 April 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ZBZ. P. BAI
Z. P. BAI
HYHao-wei YAO
Hao-wei YAO
HZH. H. Zhang
H. H. Zhang
The fire characteristics under natural ventilation in the cable compartment of the utility tunnel are studied. A series of small-scale fire experimental tests are conducted to obtain the maximum temperature below the ceiling of different ignition vertical heights and cable types. In this paper, the ceiling temperature decay and heat release rate (HRR) are studied in the cable compartment of utility tunnel. Through experimental tests, the fire characteristics of placing the fire source on the near wall side 3.0 m away from the shaft of the utility tunnel cable compartment are studied. The results showed that under the action of natural ventilation, with the decrease of fuel quantity, the mass loss of cable decreases, and the maximum temperature below the ceiling of the cable compartment in the utility tunnel decreases. ZRYJV cables burn more sufficient combustion than RVVR cables. A new empirical association for total HRR is proposed. Those experimental test results are used as validation data for the newly proposed empirical correlation of total HRR. This paper hopes to provide some basic fire safety references for the utility tunnel planning of the urban underground cable compartment.

10 March 2021 in Building Services Engineering Research & Technology
Verified
Journal Article
Open access
PDF file
ZBZ. P. BAI
Z. P. BAI
YLYanfeng Li
Yanfeng Li
JZJin Zhang
Jin Zhang
AFAlan Fewkes
Alan Fewkes
HZhua zhong
hua zhong
This study investigated the optimal design of a capillary heat exchanger device for the heat pump system and its innovative engineering application in a building. The overall aim was to use a capillary heat exchanger to obtain energy in coastal areas for promoting renewable energy in low-carbon building design. Initially, the main factors affecting the efficiency of the capillary heat exchanger were identified, a mathematical model was then established to analyse the heat transfer process. The analysis showed the flow rate and the capillary length are the key factors affecting the efficiency of the capillary heat exchanger. Secondly, to optimize the structural design of the capillary heat exchanger, the heat energy transfer is calculated with different lengths of the capillary under various flow rates in summer and winter conditions, respectively. Thirdly, a typical building is selected to analyse the application of the capillary heat exchanger for extracting energy in the coastal area. The results show the performance of the selected capillary heat exchanger heat pump system, in winter, the heat energy transfer rate is 60 W/m 2 when the seawater temperature is 3.7 °C; in summer, the heat energy transfer rate is 150 W/m 2 when the seawater temperature is 24.6 °C. Finally, the above field test results were examined using a numerical simulation model, the test and simulation results agree with each other quite well. This paper is conducive in promoting the development of the capillary heat exchanger heat pump as an innovative sustainable technology for net-zero energy and low carbon buildings using renewable energy in coastal areas. Practical application: A recently proposed capillary heat exchanger is used as an energy extraction and utilisation device to obtain energy in coastal areas for promoting renewable energy in low-carbon building design. This paper explores the application of a capillary heat exchanger as both cold and heat sources for application in typical low-rise buildings. The analysis of the heat energy transfer rate of a typical low-rise building located in a coastal area in summer and winter provides guidance for the application of capillary heat exchangers.

26 October 2024 in Fire
Verified
Journal Article
Open access
PDF file
HSHuaitao Song
Huaitao Song
YSYali Shi
Yali Shi
HYHao-wei YAO
Hao-wei YAO
XWXiaoge Wei
Xiaoge Wei
HQHengjie Qin
Hengjie Qin
YYyueyang yu
yueyang yu
In order to study the influence of wind direction on fire spread on building facades, a three-dimensional model of a high-rise building was built with PyroSim software. Numerical simulations were conducted with five wind directions (0°, 45°, 90°, 135° and 180°) and a reference wind speed of 3 m/s. The results show that the fire spread on the building facade was most significant on the leeward side, followed by the upwind condition. The horizontal spread of fire was promoted by crosswinds at 45°, 90° and 135°, while its vertical spread was inhibited. Among these, the inhibitory effect of the 45° crosswind was the greatest. The fire spread area under the leeward condition was the greatest at approximately 341.3 m2, accounting for 17.1% of the facade, and the vertical spread velocity under the condition of no wind was the fastest at 0.075 m/s. In this study, the motion characteristics of facade fire spread under different wind directions were determined, providing supporting evidence to enhance fire safety prevention and control measures in high-rise buildings.