Sk Yeahia Been Sayeed

Sk Yeahia Been Sayeed

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Verified
Journal Article
Closed access
AWAtom O. Watanabe
Atom O. Watanabe
MAMuhammad Ali
Muhammad Ali
SSSk Yeahia Been Sayeed
Sk Yeahia Been Sayeed
RTRao R. Tummala
Rao R. Tummala
PMPulugurtha Markondeya
Pulugurtha Markondeya
Increasing data rates, spectrum efficiency and energy efficiency have been driving major advances in the design and hardware integration of RF communication networks. In order to meet the data rate and efficiency metrics, 5G networks have emerged as a follow-on to 4G, and projected to have 100X higher wireless date rates and 100X lower latency than those with current 4G networks. Major challenges arise in the packaging of radio-frequency front-end modules because of the stringent low signal-loss requirements in the millimeter-wave frequency bands, and precision-impedance designs with smaller footprints and thickness. Heterogeneous integration in 3D ultra-thin packages with higher component densities and performance than with the existing 2D packages is needed to realize such 5G systems. This paper reviews the key building blocks of 5G systems and the underlying advances in packaging technologies to realize them.

8 March 2023 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Verified
Journal Article
Closed access
SSSk Yeahia Been Sayeed
Sk Yeahia Been Sayeed
SVSatheesh Bojja Venkatakrishnan
Satheesh Bojja Venkatakrishnan
JVJohn L. Volakis
John L. Volakis
PMPulugurtha Markondeya
Pulugurtha Markondeya
Wireless fully-passive neural recording systems are demonstrated with heterogeneous integration of sensing, mixing, and communication components in flexible polymer dielectric films. The recording neurosensor has an antenna, antiparallel diode, and a by-pass capacitor to modulate an incoming carrier signal with the neuropotentials and backscatter the mixed signal to an external reader circuit. Planar antennas are realized on Liquid Crystal Polymer (LCP) flexible substrates with low dielectric constant. The designed antenna topology is realized with a single metal layer and eliminates the dependency on substrate thickness, and leads to thinner sensors. This is a major advance compared to prior passive neural recording with rigid and thicker substrates and components. Approximately 80% thickness reduction and 20% volume reduction are achieved with a similar performance when compared to earlier studies. Our approach thus leads to low-cost and disposable wireless neurosensors on a flexible platform with heterogeneous integration. This paper thus advances innovative wireless neural recording in three aspects: a)advanced packaging for miniaturized neural recording with passive telemetry, through which the overall size of the sensor is reduced without degrading the performance. b) new antenna topologies for neural recording applications, and c) detailed power link analysis to estimate the minimum signal sensitivity.

30 March 2022 in IEEE Open Journal of Nanotechnology
Verified
Journal Article
Open access
AHAkeeb Hassan
Akeeb Hassan
SSSepehr Soroushiani
Sepehr Soroushiani
AAAbdulhameed Abdal
Abdulhameed Abdal
SSSk Yeahia Been Sayeed
Sk Yeahia Been Sayeed
WLWei-Chiang Lin
Wei-Chiang Lin
PMPulugurtha Markondeya
Pulugurtha Markondeya
Embedded-chip planar silver-elastomer interconnect technology is developed with flexible substrates and demonstrated for on-skin biophotonic sensor applications. This approach has several benefits and is also consistent with chip-thinning where the chip thickness is 100 microns and less. The key benefits from this approach arise because both the bottom and top sides are now available as flat surfaces for 3D integration of other components. It also results in the lowest electrical parasitics compared to flipchip with adhesives or printed-ramp interconnections with surface-assembled devices. Embedding of chips in flexible carriers was accomplished with direct screen-printed interconnects onto the chip pads in substrate cavities. Silver nanoflake-loaded polyurethane is utilized in the embedded-chip packages to provide the desired lower interconnect resistance and also reliability in flexible packages under deformed configurations. Viscoelastic models were utilized to model the interconnection stresses. Planar interconnects in flexible substrates are developed with conductive silver-loaded elastomer interconnects. This approach is compared to direct chip-on-flex assembly technology for reliability under bending and high-temperature storage. The embedded-chip technology is demonstrated through biophotonic sensor applications where light sources (LEDs) and photodetectors are embedded inside the package. Functional validation in bent configuration at low curvatures is shown by measuring pulse rate and muscle activity with human subjects. By extending this technology to nanowires in elastomers, further enhancement in electrical and reliability performance can be achieved.

26 July 2023 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Verified
Journal Article
Closed access
SSSk Yeahia Been Sayeed
Sk Yeahia Been Sayeed
HNHooman Vatan Navaz
Hooman Vatan Navaz
JVJohn L. Volakis
John L. Volakis
PMPulugurtha Markondeya
Pulugurtha Markondeya
Miniaturized fully-passive wireless seismocardiogram (SCG) cardiac monitoring devices are demonstrated with heterogenous integration of sensor and telemetry components. The novelty stems from its minimal obtrusiveness on the skin, operation at zero power and disposability because of its low cost. The key innovation is the passive wireless module comprising of a dual-band antenna, antiparallel diode, a by-pass capacitor and a piezoelectric polyvinylidene fluoride (PVDF) thin-film sensor for sensing mechanical activity of the heart. The piezoelectric film is micropatterned to enhance compliance, match with skin stiffness, provide stretchability, and convert mechanical vibrations into electrical signal (f SCG ). A 2.4 GHz signal is transmitted from an interrogator to the wireless passive module, which upconverts and mixes the signal (4.8± f SCG GHz) and retransmits it to the interrogator. The system components are embedded in a Liquid Crystal Polymer (LCP) to realize planar interconnections and minimize electrical parasitics and total thickness. The wireless passive module is 8.5×9.5×0.4 mm 3 whereas the thin, stretchable, highly-compliant piezotransducer is 30.92×22.31×0.028 mm 3 . Thus, our approach leads to is the smallest seismocardiogram cardiac monitoring device reported until now.

9 December 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
GAGhaleb Saleh Ghaleb Al-Duhni
Ghaleb Saleh Ghaleb Al-Duhni
SSSk Yeahia Been Sayeed
Sk Yeahia Been Sayeed
VJVeeru Jaiswal
Veeru Jaiswal
RBRyan Bahr
Ryan Bahr
JNJaim Nulman
Jaim Nulman
PMPulugurtha Markondeya
Pulugurtha Markondeya
Health-monitoring systems often integrate sensory interfaces with passive telemetry to create wireless and untethered continuous real-time diagnostic functions. Despite the circuit simplicity and miniaturization with this topology, traditional packaging approach with surface-mount components create a major barrier towards miniaturization and signal quality. To address this, embedded and passive neural recording telemetry systems are fabricated with three key technical features: 1) Passive telemetry to achieve zero-power neural recording 2) 3D-printed package 3) Embedded components inside the package. Nanopackaging with 3D printing of silver and epoxy is utilized to create cavities for embedding diodes. This additive codeposition is also effectively utilized to embed multilayered film capacitors to enable unique 3D designs. The fully-embedded and miniaturized system achieves higher sideband neural power by an additional 5 dB compared to that of discrete components, which directly implies higher signal sensitivity. The resulting miniaturized recording unit of 8.2 × 8.5 × 1 mm 3 is capable of wireless acquisition with signal strengths as low as 160 μVpp. This novel approach of fully-embedded components in package build-up layers will eventually lead to future chip-scale systems with enhanced performance and reliability.

16 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SSSk Yeahia Been Sayeed
Sk Yeahia Been Sayeed
GDGhaleb Al Duhni
Ghaleb Al Duhni
HNHooman Vatan Navaz
Hooman Vatan Navaz
JVJohn L. Volakis
John L. Volakis
PMPulugurtha Markondeya
Pulugurtha Markondeya
Wireless passive neural recording systems integrate sensory electrophysiological interfaces with a backscattering-based telemetry system. Despite the circuit simplicity and miniaturization with this topology, the high electrode–tissue impedance creates a major barrier to achieving high signal sensitivity and low telemetry power. In this paper, buffered impedance is utilized to address this limitation. The resulting passive telemetry-based wireless neural recording is implemented with thin flexible packages. Thus, the paper reports neural recording implants and integrator systems with three improved features: (1) passive high impedance matching with a simple buffer circuit, (2) a bypass capacitor to route the high frequency and improve mixer performance, and (3) system packaging with an integrated, flexible, biocompatible patch to capture the neural signal. The patch consists of a U-slot dual-band patch antenna that receives the transmitted power from the interrogator and backscatters the modulated carrier power at a different frequency. When the incoming power was 5–10 dBm, the neurosensor could communicate with the interrogator at a maximum distance of 5 cm. A biosignal as low as 80 µV peak was detected at the receiver.