Jessica Lima

Ms. Jessica Lima

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
AVAna Cecilia Villa-Parra
Ana Cecilia Villa-Parra
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
JLJessica Lima
Jessica Lima
ANAnselmo Frizera Neto
Anselmo Frizera Neto
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
Robotic devices for rehabilitation and gait assistance have greatly advanced with the objective of improving both the mobility and quality of life of people with motion impairments. To encourage active participation of the user, the use of admittance control strategy is one of the most appropriate approaches, which requires methods for online adjustment of impedance components. Such approach is cited by the literature as a challenge to guaranteeing a suitable dynamic performance. This work proposes a method for online knee impedance modulation, which generates variable gains through the gait cycle according to the users’ anthropometric data and gait sub-phases recognized with footswitch signals. This approach was evaluated in an active knee orthosis with three variable gain patterns to obtain a suitable condition to implement a stance controller: two different gain patterns to support the knee in stance phase, and a third pattern for gait without knee support. The knee angle and torque were measured during the experimental protocol to compare both temporospatial parameters and kinematics data with other studies of gait with knee exoskeletons. The users rated scores related to their satisfaction with both the device and controller through QUEST questionnaires. Experimental results showed that the admittance controller proposed here offered knee support in 50% of the gait cycle, and the walking speed was not significantly different between the three gain patterns (p = 0.067). A positive effect of the controller on users regarding safety during gait was found with a score of 4 in a scale of 5. Therefore, the approach demonstrates good performance to adjust impedance components providing knee support in stance phase.

21 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JLJessica Lima
Jessica Lima
Leticia SilvaLeticia Silva
Leticia Silva
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
VCVivianne Flávia Cardoso
Vivianne Flávia Cardoso
ENEster Miyuki Nakamura-Palacios
Ester Miyuki Nakamura-Palacios
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
Stroke is a debilitating clinical condition resulting from a brain infarction or hemorrhage that poses significant challenges for motor function restoration. Previous studies have shown the potential of applying transcranial direct current stimulation (tDCS) to improve neuroplasticity in patients with neurological diseases or disorders. By modulating the cortical excitability, tDCS can enhance the effects of conventional therapies. While upper-limb recovery has been extensively studied, research on lower limbs is still limited, despite their important role in locomotion, independence, and good quality of life. As the life and social costs due to neuromuscular disability are significant, the relatively low cost, safety, and portability of tDCS devices, combined with low-cost robotic systems, can optimize therapy and reduce rehabilitation costs, increasing access to cutting-edge technologies for neuromuscular rehabilitation. This study explores a novel approach by utilizing the following processes in sequence: tDCS, a motor imagery (MI)-based brain-computer interface (BCI) with virtual reality (VR), and a motorized pedal end-effector. These are applied to enhance the brain plasticity and accelerate the motor recovery of post-stroke patients. The results are particularly relevant for post-stroke patients with severe lower-limb impairments, as the system proposed here provides motor training in a real-time closed-loop design, promoting cortical excitability around the foot area (Cz) while the patient directly commands with his/her brain signals the motorized pedal. This strategy has the potential to significantly improve rehabilitation outcomes. The study design follows an alternating treatment design (ATD), which involves a double-blind approach to measure improvements in both physical function and brain activity in post-stroke patients. The results indicate positive trends in the motor function, coordination, and speed of the affected limb, as well as sensory improvements. The analysis of event-related desynchronization (ERD) from EEG signals reveals significant modulations in Mu, low beta, and high beta rhythms. Although this study does not provide conclusive evidence for the superiority of adjuvant mental practice training over conventional therapy alone, it highlights the need for larger-scale investigations.

26 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
AVAna Cecilia Villa-Parra
Ana Cecilia Villa-Parra
JLJessica Lima
Jessica Lima
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
LVLaura Susana Vargas Valencia
Laura Susana Vargas Valencia
ANAnselmo Frizera Neto
Anselmo Frizera Neto
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
The goal of this study is the assessment of an assistive control approach applied to an active knee orthosis plus a walker for gait rehabilitation. The study evaluates post-stroke patients and healthy subjects (control group) in terms of kinematics, kinetics, and muscle activity. Muscle and gait information of interest were acquired from their lower limbs and trunk, and a comparison was conducted between patients and control group. Signals from plantar pressure, gait phase, and knee angle and torque were acquired during gait, which allowed us to verify that the stance control strategy proposed here was efficient at improving the patients’ gaits (comparing their results to the control group), without the necessity of imposing a fixed knee trajectory. An innovative evaluation of trunk muscles related to the maintenance of dynamic postural equilibrium during gait assisted by our active knee orthosis plus walker was also conducted through inertial sensors. An increase in gait cycle (stance phase) was also observed when comparing the results of this study to our previous work. Regarding the kinematics, the maximum knee torque was lower for patients when compared to the control group, which implies that our orthosis did not demand from the patients a knee torque greater than that for healthy subjects. Through surface electromyography (sEMG) analysis, a significant reduction in trunk muscle activation and fatigability, before and during the use of our orthosis by patients, was also observed. This suggest that our orthosis, together with the assistive control approach proposed here, is promising and could be considered to complement post-stroke patient gait rehabilitation.

14 October 2018
Verified
Book Chapter
Closed access
PDF file
AVAna Cecilia Villa-Parra
Ana Cecilia Villa-Parra
JLJessica Lima
Jessica Lima
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
ANAnselmo Frizera Neto
Anselmo Frizera Neto
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho

21 May 2023
Verified
Book Chapter
Closed access
PDF file
JLJessica Lima
Jessica Lima
AVAna Cecilia Villa-Parra
Ana Cecilia Villa-Parra
LVLaura Susana Vargas Valencia
Laura Susana Vargas Valencia
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
TFT. Freire-Bastos
T. Freire-Bastos

11 February 2026 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
Leticia SilvaLeticia Silva
Leticia Silva
JLJessica Lima
Jessica Lima
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
This study proposes a novel two-step calibration strategy in a Motor Imagery (MI)-based Brain-Computer Interface (BCI) system for lower-limb post-stroke patients rehabilitation, using electroencephalography (EEG) signals, a virtual reality serious game, and a pedal end-effector. This research proposes a novel MI feature extraction algorithm combining EEG data from pedaling MI and actual movements using k-Nearest Neighbors (k-NN) and probability analysis. The extracted features are used to re-calibrate the BCI system, and improve its accuracy. Initially, participants performed 20 MI trials without feedback (open-loop, Calibration Mode #1) while receiving passive movement. During this phase, EEG data were processed using the Riemannian Geometry method to train a Linear Discriminant Analysis (LDA) classifier. In the second step (closed-loop, Calibration Mode #2), feedback through passive movement was provided, changing the pedal’s speed according to the MI classification consistency. A chronic post-stroke patient tested the proposed BCI system, first receiving transcranial Direct Current Stimulation (tDCS) before each session. The calibration strategy improved classification accuracy from 52.60% (Mode #1) to 86.74% (Mode #2). The classification remained effective throughout sessions, allowing for immediate feedback-driven training while collecting more reliable EEG MI data. The BCI developed here is able to provide post-stroke patient rehabilitation by engaging lower-limb central and peripheral mechanisms through simultaneous MI and passive pedaling during extended workout sessions.