Carla Antonacci

Dr. Carla Antonacci

Measurements and Biomedical Instrumentation, Università Campus Bio-Medico, Rome, Lazio, Italy
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
CACarla Antonacci
Carla Antonacci
Umile Giuseppe LongoUmile Giuseppe Longo
Umile Giuseppe Longo
ANAra Nazarian
Ara Nazarian
Emiliano SchenaEmiliano Schena
Emiliano Schena
ACArianna Carnevale
Arianna Carnevale
Monitoring shoulder kinematics, including the scapular segment, is of great relevance in the orthopaedic field. Among wearable systems, magneto-inertial measurement units (M-IMUs) represent a valid alternative for applications in unstructured environments. The aim of this systematic literature review is to report and describe the existing methods to estimate 3D scapular movements through wearable systems integrating M-IMUs. A comprehensive search of PubMed, IEEE Xplore, and Web of Science was performed, and results were included up to May 2023. A total of 14 articles was included. The results showed high heterogeneity among studies regarding calibration procedures, tasks executed, and the population. Two different techniques were described, i.e., with the x-axis aligned with the cranial edge of the scapular spine or positioned on the flat surface of the acromion with the x-axis perpendicular to the scapular spine. Sensor placement affected the scapular motion and, also, the kinematic output. Further studies should be conducted to establish a universal protocol that reduces the variability among studies. Establishing a protocol that can be carried out without difficulty or pain by patients with shoulder musculoskeletal disorders could be of great clinical relevance for patients and clinicians to monitor 3D scapular kinematics in unstructured settings or during common clinical practice.

19 February 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
ACArianna Carnevale
Arianna Carnevale
ARAlessandra Raso
Alessandra Raso
CACarla Antonacci
Carla Antonacci
LMLetizia Mancini
Letizia Mancini
ACAlessandra Corradini
Alessandra Corradini
Umile Giuseppe LongoUmile Giuseppe Longo
Umile Giuseppe Longo
Background: Socially Assistive Robots (SARs) represent an innovative approach in rehabilitation technology, significantly enhancing the support and motivation for individuals across diverse rehabilitation settings. Despite their growing utilization, especially in stroke recovery and pediatric rehabilitation, their potential in musculoskeletal and orthopedic rehabilitation remains largely underexplored. Although there is methodological and outcome variability across the included studies, this review aims to critically evaluate and summarize the research on SARs in rehabilitation, providing a thorough overview of the current evidence and practical applications. Methods: A comprehensive search was conducted across multiple databases, resulting in the selection of 20 studies for analysis. The reviewed papers were categorized into three main classes based on the roles of the robots in rehabilitation: Motivation, Imitation, and Feedback Providers. Results: The analysis highlights that SARs significantly improve adherence to rehabilitation programs, enhance motor function, and increase motivation across clinical and home settings. Robots such as NAO, Pepper, and ZORA demonstrated high efficacy, particularly in stroke recovery and pediatric rehabilitation. Conclusions: SARs offer transformative benefits in rehabilitation, providing scalable, personalized solutions through motivational support, guided exercises, and real-time feedback. Their integration into orthopedic rehabilitation could address critical clinical needs, enhancing precision in exercises, adherence to long-term programs, and overall patient outcomes. Future research should prioritize the development and validation of SAR-based interventions for musculoskeletal disorders to unlock their full potential in this domain.

12 July 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
LSLorenzo De Sanctis
Lorenzo De Sanctis
ACArianna Carnevale
Arianna Carnevale
CACarla Antonacci
Carla Antonacci
EFEliodoro Faiella
Eliodoro Faiella
Emiliano SchenaEmiliano Schena
Emiliano Schena
Umile Giuseppe LongoUmile Giuseppe Longo
Umile Giuseppe Longo
In orthopedics, X-rays and computed tomography (CT) scans play pivotal roles in diagnosing and treating bone pathologies. Machine bulkiness and the emission of ionizing radiation remain the main problems associated with these techniques. The accessibility and low risks related to ultrasound handling make it a popular 2D imaging method. Indeed, 3D ultrasound assembles 2D slices into a 3D volume. This study aimed to implement a probe-tracking method for 6 DoF 3D ultrasound. The proposed method involves a dodecahedron with ArUco markers attached, enabling computer vision tracking of the ultrasound probe’s position and orientation. The algorithm focuses on the data acquisition phase but covers the basic reconstruction required for data generation and analysis. In the best case, the analysis revealed an average error norm of 2.858 mm with a standard deviation norm of 5.534 mm compared to an infrared optical tracking system used as a reference. This study demonstrates the feasibility of performing volumetric imaging without ionizing radiation or bulky systems. This marker-based approach shows promise for enhancing orthopedic imaging, providing a more accessible imaging modality for helping clinicians to diagnose pathologies regarding complex joints, such as the shoulder, replacing standard infrared tracking systems known to suffer from marker occlusion problems.

20 December 2025 in Instruments
Verified
Journal Article
Open access
PDF file
CACarla Antonacci
Carla Antonacci
ACArianna Carnevale
Arianna Carnevale
LMLetizia Mancini
Letizia Mancini
Alessandro de SireAlessandro de Sire
Alessandro de Sire
PDPieter P.R.N. D'Hooghe
Pieter P.R.N. D'Hooghe
Umile Giuseppe LongoUmile Giuseppe Longo
Umile Giuseppe Longo
Accurate measurement of shoulder muscle strength is important for diagnosis, treatment planning, and monitoring recovery. Hand-held dynamometers (HHDs) are widely used in clinical practice but are affected by operator strength, patient positioning, and device stabilization, particularly under high-load conditions. No previous study has directly compared HHD measurements with a reference load cell in a rigid serial configuration or evaluated the effect of different load cell signal processing strategies on the final strength value. The aim of this study was to compare HHD measurements with those obtained from a reference load cell in a rigid serial configuration and to assess how different signal processing strategies applied to load cell data influence the final outcomes. A custom 3D-printed support was developed to align a commercial HHD and a load cell in series, ensuring identical loading conditions. Measurements were performed under two conditions: (i) application of known weights (9.81–98.10 N) and (ii) standardized strength tasks in five healthy volunteers. Agreement between instruments was evaluated using Bland–Altman analysis and Root Mean Square Error (RMSE). In static validation (i.e., experiments applying know weights), the load cell demonstrated stable performance, with standard deviations below 1% of the applied load. HHD variability increased with load, with RMSE rising from 0.55 N at 9.81 N to 5.06 N at 98.10 N. In human testing, the HHD consistently underestimated muscle strength compared with the load cell, with mean differences ranging from −15 N to −19 N, over exerted force ranges of approximately 20–90 N. Overall, the load cell provided stable reference measurements, while the choice of signal processing strategy influenced the results: plateau-phase analysis tended to reduce systematic bias but did not consistently narrow the limits of agreement.