YUKI NAKAMITSU

Dr. YUKI NAKAMITSU


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2023 in Current Oncology
Verified
Journal Article
Open access
PDF file
WAWlla Al-Hammad
Wlla Al-Hammad
MKMasahiro Kuroda
Masahiro Kuroda
RKRyo Kamizaki
Ryo Kamizaki
NTNouha Tekiki
Nouha Tekiki
HIHinata Ishizaka
Hinata Ishizaka
JAJunichi Asaumi
Junichi Asaumi
Deep inspiration breath-hold (DIBH) is an excellent technique to reduce the incidental radiation received by the heart during radiotherapy in patients with breast cancer. However, DIBH is costly and time-consuming for patients and radiotherapy staff. In Asian countries, the use of DIBH is restricted due to the limited number of patients with a high mean heart dose (MHD) and the shortage of radiotherapy personnel and equipment compared to that in the USA. This study aimed to develop, evaluate, and compare the performance of ten machine learning algorithms for predicting MHD using a patient’s body mass index and single-slice CT parameters to identify patients who may not require DIBH. Machine learning models were built and tested using a dataset containing 207 patients with left-sided breast cancer who were treated with field-in-field radiotherapy with free breathing. The average MHD was 251 cGy. Stratified repeated four-fold cross-validation was used to build models using 165 training data. The models were compared internally using their average performance metrics: F2 score, AUC, recall, accuracy, Cohen’s kappa, and Matthews correlation coefficient. The final performance evaluation for each model was further externally analyzed using 42 unseen test data. The performance of each model was evaluated as a binary classifier by setting the cut-off value of MHD ≥ 300 cGy. The deep neural network (DNN) achieved the highest F2 score (78.9%). Most models successfully classified all patients with high MHD as true positive. This study indicates that the ten models, especially the DNN, might have the potential to identify patients who may not require DIBH.

7 December 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
YFYuka Fukumura
Yuka Fukumura
MKMasahiro Kuroda
Masahiro Kuroda
SYSuzuka Yoshida
Suzuka Yoshida
YNYoshihide Nakamura
Yoshihide Nakamura
YNYUKI NAKAMITSU
YUKI NAKAMITSU
JAJunichi Asaumi
Junichi Asaumi
We evaluated the usefulness of simple diffusion kurtosis (SD) imaging, which was developed to generate diffusion kurtosis images simultaneously with an apparent diffusion coefficient (ADC) map for 27 cystic disease lesions in the head and neck region. The mean kurtosis (MK) and ADC values were calculated for the cystic space. The MK values were dentigerous cyst (DC): 0.74, odontogenic keratocyst (OKC): 0.86, ranula (R): 0.13, and mucous cyst (M): 0, and the ADC values were DC: 1364 × 10−6 mm2/s, OKC: 925 × 10−6 mm2/s, R: 2718 × 10−6 mm2/s, and M: 2686 × 10−6 mm2/s. The MK values of DC and OKC were significantly higher than those of R and M, whereas their ADC values were significantly lower. One reason for the characteristic signal values in diffusion-weighted images of DC may be related to content components such as fibrous tissue and exudate cells. When imaging cystic disease in the head and neck region using SD imaging, the maximum b-value setting at the time of imaging should be limited to approximately 1200 s/mm2 for accurate MK value calculation. This study is the first to show that the MK values of DC are characteristically higher than those of other cysts.

20 March 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
YNYUKI NAKAMITSU
YUKI NAKAMITSU
MKMasahiro Kuroda
Masahiro Kuroda
YSYudai Shimizu
Yudai Shimizu
KKKazuhiro Kuroda
Kazuhiro Kuroda
YYYuuki Yoshimura
Yuuki Yoshimura
JAJunichi Asaumi
Junichi Asaumi
Background: Our initial clinical study using simple diffusion kurtosis imaging (SDI), which simultaneously produces a diffusion kurtosis image (DKI) and an apparent diffusion coefficient map, confirmed the usefulness of SDI for tumor diagnosis. However, the obtained DKI had noticeable variability in the mean kurtosis (MK) values, which is inherent to SDI. We aimed to improve this variability in SDI by preprocessing with three different filters (Gaussian [G], median [M], and nonlocal mean) of the diffusion-weighted images used for SDI. Methods: The usefulness of filter parameters for diagnosis was examined in basic and clinical studies involving 13 patients with head and neck tumors. Results: The filter parameters, which did not change the median MK value, but reduced the variability and significantly homogenized the MK values in tumor and normal tissues in both basic and clinical studies, were identified. In the receiver operating characteristic curve analysis for distinguishing tumors from normal tissues using MK values, the area under curve values significantly improved from 0.627 without filters to 0.641 with G (σ = 0.5) and 0.638 with M (radius = 0.5). Conclusions: Thus, image pretreatment with G and M for SDI was shown to be useful for improving tumor diagnosis in clinical practice.

20 March 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
SYSuzuka Yoshida
Suzuka Yoshida
MKMasahiro Kuroda
Masahiro Kuroda
YNYoshihide Nakamura
Yoshihide Nakamura
YFYuka Fukumura
Yuka Fukumura
YNYUKI NAKAMITSU
YUKI NAKAMITSU
JAJunichi Asaumi
Junichi Asaumi
Background/Objectives: Mean kurtosis (MK) values in simple diffusion kurtosis imaging (SDI)—a type of diffusion kurtosis imaging (DKI)—have been reported to be useful in the diagnosis of head and neck malignancies, for which pre-processing with smoothing filters has been reported to improve the diagnostic accuracy. Multi-parameter analysis using DKI in combination with other image types has recently been reported to improve the diagnostic performance. The purpose of this study was to evaluate the usefulness of machine learning (ML)-based multi-parameter analysis using the MK and apparent diffusion coefficient (ADC) values—which can be acquired simultaneously through SDI—for the differential diagnosis of benign and malignant head and neck tumors, which is important for determining the treatment strategy, as well as examining the usefulness of filter pre-processing. Methods: A total of 32 pathologically diagnosed head and neck tumors were included in the study, and a Gaussian filter was used for image pre-processing. MK and ADC values were extracted from pixels within the tumor area and used as explanatory variables. Five ML algorithms were used to create models for the prediction of tumor status (benign or malignant), which were evaluated through ROC analysis. Results: Bi-parameter analysis with gradient boosting achieved the best diagnostic performance, with an AUC of 0.81. Conclusions: The usefulness of bi-parameter analysis with ML methods for the differential diagnosis of benign and malignant head and neck tumors using SDI data were demonstrated.