We evaluated the usefulness of simple diffusion kurtosis (SD) imaging, which was developed to generate diffusion kurtosis images simultaneously with an apparent diffusion coefficient (ADC) map for 27 cystic disease lesions in the head and neck region. The mean kurtosis (MK) and ADC values were calculated for the cystic space. The MK values were dentigerous cyst (DC): 0.74, odontogenic keratocyst (OKC): 0.86, ranula (R): 0.13, and mucous cyst (M): 0, and the ADC values were DC: 1364 × 10−6 mm2/s, OKC: 925 × 10−6 mm2/s, R: 2718 × 10−6 mm2/s, and M: 2686 × 10−6 mm2/s. The MK values of DC and OKC were significantly higher than those of R and M, whereas their ADC values were significantly lower. One reason for the characteristic signal values in diffusion-weighted images of DC may be related to content components such as fibrous tissue and exudate cells. When imaging cystic disease in the head and neck region using SD imaging, the maximum b-value setting at the time of imaging should be limited to approximately 1200 s/mm2 for accurate MK value calculation. This study is the first to show that the MK values of DC are characteristically higher than those of other cysts.
Background: Our initial clinical study using simple diffusion kurtosis imaging (SDI), which simultaneously produces a diffusion kurtosis image (DKI) and an apparent diffusion coefficient map, confirmed the usefulness of SDI for tumor diagnosis. However, the obtained DKI had noticeable variability in the mean kurtosis (MK) values, which is inherent to SDI. We aimed to improve this variability in SDI by preprocessing with three different filters (Gaussian [G], median [M], and nonlocal mean) of the diffusion-weighted images used for SDI. Methods: The usefulness of filter parameters for diagnosis was examined in basic and clinical studies involving 13 patients with head and neck tumors. Results: The filter parameters, which did not change the median MK value, but reduced the variability and significantly homogenized the MK values in tumor and normal tissues in both basic and clinical studies, were identified. In the receiver operating characteristic curve analysis for distinguishing tumors from normal tissues using MK values, the area under curve values significantly improved from 0.627 without filters to 0.641 with G (σ = 0.5) and 0.638 with M (radius = 0.5). Conclusions: Thus, image pretreatment with G and M for SDI was shown to be useful for improving tumor diagnosis in clinical practice.
Background/Objectives: Mean kurtosis (MK) values in simple diffusion kurtosis imaging (SDI)—a type of diffusion kurtosis imaging (DKI)—have been reported to be useful in the diagnosis of head and neck malignancies, for which pre-processing with smoothing filters has been reported to improve the diagnostic accuracy. Multi-parameter analysis using DKI in combination with other image types has recently been reported to improve the diagnostic performance. The purpose of this study was to evaluate the usefulness of machine learning (ML)-based multi-parameter analysis using the MK and apparent diffusion coefficient (ADC) values—which can be acquired simultaneously through SDI—for the differential diagnosis of benign and malignant head and neck tumors, which is important for determining the treatment strategy, as well as examining the usefulness of filter pre-processing. Methods: A total of 32 pathologically diagnosed head and neck tumors were included in the study, and a Gaussian filter was used for image pre-processing. MK and ADC values were extracted from pixels within the tumor area and used as explanatory variables. Five ML algorithms were used to create models for the prediction of tumor status (benign or malignant), which were evaluated through ROC analysis. Results: Bi-parameter analysis with gradient boosting achieved the best diagnostic performance, with an AUC of 0.81. Conclusions: The usefulness of bi-parameter analysis with ML methods for the differential diagnosis of benign and malignant head and neck tumors using SDI data were demonstrated.