Yoshihide Nakamura

Mr. Yoshihide Nakamura

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
YFYuka Fukumura
Yuka Fukumura
MKMasahiro Kuroda
Masahiro Kuroda
SYSuzuka Yoshida
Suzuka Yoshida
YNYoshihide Nakamura
Yoshihide Nakamura
YNYUKI NAKAMITSU
YUKI NAKAMITSU
JAJunichi Asaumi
Junichi Asaumi
We evaluated the usefulness of simple diffusion kurtosis (SD) imaging, which was developed to generate diffusion kurtosis images simultaneously with an apparent diffusion coefficient (ADC) map for 27 cystic disease lesions in the head and neck region. The mean kurtosis (MK) and ADC values were calculated for the cystic space. The MK values were dentigerous cyst (DC): 0.74, odontogenic keratocyst (OKC): 0.86, ranula (R): 0.13, and mucous cyst (M): 0, and the ADC values were DC: 1364 × 10−6 mm2/s, OKC: 925 × 10−6 mm2/s, R: 2718 × 10−6 mm2/s, and M: 2686 × 10−6 mm2/s. The MK values of DC and OKC were significantly higher than those of R and M, whereas their ADC values were significantly lower. One reason for the characteristic signal values in diffusion-weighted images of DC may be related to content components such as fibrous tissue and exudate cells. When imaging cystic disease in the head and neck region using SD imaging, the maximum b-value setting at the time of imaging should be limited to approximately 1200 s/mm2 for accurate MK value calculation. This study is the first to show that the MK values of DC are characteristically higher than those of other cysts.

10 March 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
WAWlla Al-Hammad
Wlla Al-Hammad
MKMasahiro Kuroda
Masahiro Kuroda
GAGhaida AlJamal
Ghaida AlJamal
MFMamiko Fujikura
Mamiko Fujikura
RKRyo Kamizaki
Ryo Kamizaki
JAJunichi Asaumi
Junichi Asaumi
Background/Objectives: Deep inspiration breath-hold (DIBH) is a commonly used technique to reduce the mean heart dose (MHD), which is critical for minimizing late cardiac side effects in breast cancer patients undergoing radiation therapy (RT). Although previous studies have explored the potential of machine learning (ML) to predict which patients might benefit from DIBH, none have rigorously assessed ML model performance across various MHD thresholds and parameter settings. This study aims to evaluate the robustness of ML models in predicting the need for DIBH across different clinical scenarios. Methods: Using data from 207 breast cancer patients treated with RT, we developed and tested ML models at three MHD cut-off values (240, 270, and 300 cGy), considering variations in the number of independent variables (three vs. six) and folds in the cross-validation (three, four, and five). Robustness was defined as achieving high F2 scores and low instability in predictive performance. Results: Our findings indicate that the decision tree (DT) model demonstrated consistently high robustness at 240 and 270 cGy, while the random forest model performed optimally at 300 cGy. At 240 cGy, a threshold critical to minimize late cardiac risks, the DT model exhibited stable predictive power, reducing the risk of overestimating DIBH necessity. Conclusions: These results suggest that the DT model, particularly at lower MHD thresholds, may be the most reliable for clinical applications. By providing a tool for targeted DIBH implementation, this model has the potential to enhance patient-specific treatment planning and improve clinical outcomes in RT.

20 March 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
YNYUKI NAKAMITSU
YUKI NAKAMITSU
MKMasahiro Kuroda
Masahiro Kuroda
YSYudai Shimizu
Yudai Shimizu
KKKazuhiro Kuroda
Kazuhiro Kuroda
YYYuuki Yoshimura
Yuuki Yoshimura
JAJunichi Asaumi
Junichi Asaumi
Background: Our initial clinical study using simple diffusion kurtosis imaging (SDI), which simultaneously produces a diffusion kurtosis image (DKI) and an apparent diffusion coefficient map, confirmed the usefulness of SDI for tumor diagnosis. However, the obtained DKI had noticeable variability in the mean kurtosis (MK) values, which is inherent to SDI. We aimed to improve this variability in SDI by preprocessing with three different filters (Gaussian [G], median [M], and nonlocal mean) of the diffusion-weighted images used for SDI. Methods: The usefulness of filter parameters for diagnosis was examined in basic and clinical studies involving 13 patients with head and neck tumors. Results: The filter parameters, which did not change the median MK value, but reduced the variability and significantly homogenized the MK values in tumor and normal tissues in both basic and clinical studies, were identified. In the receiver operating characteristic curve analysis for distinguishing tumors from normal tissues using MK values, the area under curve values significantly improved from 0.627 without filters to 0.641 with G (σ = 0.5) and 0.638 with M (radius = 0.5). Conclusions: Thus, image pretreatment with G and M for SDI was shown to be useful for improving tumor diagnosis in clinical practice.

20 March 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
SYSuzuka Yoshida
Suzuka Yoshida
MKMasahiro Kuroda
Masahiro Kuroda
YNYoshihide Nakamura
Yoshihide Nakamura
YFYuka Fukumura
Yuka Fukumura
YNYUKI NAKAMITSU
YUKI NAKAMITSU
JAJunichi Asaumi
Junichi Asaumi
Background/Objectives: Mean kurtosis (MK) values in simple diffusion kurtosis imaging (SDI)—a type of diffusion kurtosis imaging (DKI)—have been reported to be useful in the diagnosis of head and neck malignancies, for which pre-processing with smoothing filters has been reported to improve the diagnostic accuracy. Multi-parameter analysis using DKI in combination with other image types has recently been reported to improve the diagnostic performance. The purpose of this study was to evaluate the usefulness of machine learning (ML)-based multi-parameter analysis using the MK and apparent diffusion coefficient (ADC) values—which can be acquired simultaneously through SDI—for the differential diagnosis of benign and malignant head and neck tumors, which is important for determining the treatment strategy, as well as examining the usefulness of filter pre-processing. Methods: A total of 32 pathologically diagnosed head and neck tumors were included in the study, and a Gaussian filter was used for image pre-processing. MK and ADC values were extracted from pixels within the tumor area and used as explanatory variables. Five ML algorithms were used to create models for the prediction of tumor status (benign or malignant), which were evaluated through ROC analysis. Results: Bi-parameter analysis with gradient boosting achieved the best diagnostic performance, with an AUC of 0.81. Conclusions: The usefulness of bi-parameter analysis with ML methods for the differential diagnosis of benign and malignant head and neck tumors using SDI data were demonstrated.