Madison Singleton

Ms. Madison Singleton

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 1994 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
PDF file
PCP G Carolan
P G Carolan
SFS J Fielding
S J Fielding
SGS Gerasimov
S Gerasimov
JHJ Hugill
J Hugill
AMA W Morris
A W Morris
DTD L Trotman
D L Trotman
The COMPASS-D tokamak has recently obtained H-mode plasmas in a single-null X-point configuration with no additional heating. Clear H-mode signatures have been observed including reduction in Dalpha light and the unmistakable appearance of ELMs and ELM-free periods. Recycling and gas puff can play crucial roles in achieving and terminating the H-modes. The emergence of distinct ELMs, from the apparently-random fluctuations, of the background Dalpha light, is usually one of progression, taking some 10s of ms rather than a sudden discontinuity. The relatively slow evolution allows for detail examination of important phenomena, such as improvements to confinement and fluid rotation. The H-mode quality improves with density, unless impurity accumulation becomes important. Improvements to the energy and particle confinement are observed and are accompanied by positive increases in the radial electric field at approximately=4 cm inside the last closed flux surface (LCFS). The ohmic powers in discharges with clearly defined H-modes have not been less, so far, than the power obtained from power threshold scalings from larger machines.

1 March 2024 in Instruments
Verified
Journal Article
Open access
PDF file
James RosenzweigJames Rosenzweig
James Rosenzweig
GAGerard Andonian
Gerard Andonian
RARonald Agustsson
Ronald Agustsson
PAPetr M. Anisimov
Petr M. Anisimov
AAAurora Araujo
Aurora Araujo
MYMonika Yadav
Monika Yadav
Recently, considerable work has been directed at the development of an ultracompact X-ray free-electron laser (UCXFEL) based on emerging techniques in high-field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm (1.24 keV) UCXFEL with a length and cost over an order of magnitude below current X-ray free-electron lasers (XFELs) has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being vigorously developed for use as instruments to enable next-generation chip manufacturing through use as a high-flux, few nm lithography source. This new role suggests consideration of XFELs to urgently address emerging demands in the semiconductor device sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing. Indeed, it has been shown that one may use coherent X-rays to perform 10–20 nm class resolution surveys of macroscopic, cm scale structures such as chips, using ptychographic laminography techniques. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes, and increased levels of coherence, as well as methods of applying such a source for ptychographic laminography to microelectronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative XFEL-based application, outlining both FEL and metrology system challenges.

18 June 2026 in Physical Review Letters
Verified
Journal Article
Open access
DBDmitrii S. Bespalov
Dmitrii S. Bespalov
UZUlf Zastrau
Ulf Zastrau
ZMzhandos moldabekov
zhandos moldabekov
TGThomas Gawne
Thomas Gawne
TDTobias Dornheim
Tobias Dornheim
TPThomas Preston
Thomas Preston
The robust diagnosis of conditions generated in warm dense matter experiments remains a persistent challenge. Here, we describe the measurement of shock-compressed aluminium at 50 GPa with angle-resolved femtosecond x-ray Thomson scattering (XRTS) over a wide range of scattering wave vectors at the European X-Ray Free-Electron Laser. The measured plasmon dispersion and line shape show that the standard approach for analyzing XRTS spectra, using uniform-electron-gas models, systematically overestimates the resonance energy by up to 8 eV. We present an approach using methods that agrees within the experimental uncertainty and demonstrates how accounting for shock-induced disorder in shock-compressed systems is critical for their understanding, providing evidence that treatments are required for reliable XRTS inference in warm dense aluminium.

5 January 2024 in Instruments
Verified
Journal Article
Open access
PDF file
MSMadison Singleton
Madison Singleton
James RosenzweigJames Rosenzweig
James Rosenzweig
JTJingyi Tang
Jingyi Tang
ZHZhirong Huang
Zhirong Huang
There is a growing interest in designing and building compact X-ray Free Electron Lasers (FELs) for scientific and industry applications. In this paper, we report an X-ray Regenerative Amplifier FEL (XRAFEL) design based on a proposed Ultra Compact X-ray FEL configuration. Our results show that an XRAFEL can dramatically enhance the temporal coherence and increase the spectral brightness of the radiation in the hard X-ray regime without increasing the footprint of the FEL configuration. The proposed compact, fully coherent, and high-flux hard X-ray source holds promise as a valuable candidate for a wide range of high-impact applications in both academia and industry.

28 November 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
James RosenzweigJames Rosenzweig
James Rosenzweig
GAGerard Andonian
Gerard Andonian
RARonald Agustsson
Ronald Agustsson
PAPetr M. Anisimov
Petr M. Anisimov
AAAurora Araujo
Aurora Araujo
MYMonika Yadav
Monika Yadav
Recently, considerable work has been directed at development of a ultra-compact X-ray free-electron laser based on emerging techniques in high field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness, and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm XFEL with a length and cost over an order of magnitude below current XFELs has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being urgently developed for use as an instrument to enable next generation chip manufacturing through use as a high flux, few-nm lithography source. This new role suggests consideration of XFELs to addressed urgently emerging demands in this sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing: a coherent hard X-ray source which enables frontier metrology methods. Indeed, it has been shown that one may use coherent X-rays to perform 10 nm-class resolution surveys of macroscopic, cm-scale structures such as chips, using ptychographic laminography. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes and levels of coherence, and methods of applying such a source for ptychographic laminography to micro-electronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative FEL-based application, outlining FEL and metrology system challenges.

1 November 2026 in Review of Scientific Instruments
Verified
Journal Article
Closed access
IKI. Kunz
I. Kunz
WMW. M. Martin
W. M. Martin
LAL. Andersen
L. Andersen
ZAZ. Abhari
Z. Abhari
HBH. M. Bellenbaum
H. M. Bellenbaum
LFL. B. Fletcher
L. B. Fletcher
We report the first demonstration of x-ray Thomson scattering (XRTS) at the SPring-8 Angstrom Compact free-electron LAser (SACLA) using a compact, multi-diagnostic platform designed for x-ray pump–probe experiments. The setup integrates x-ray diffraction (XRD) and three Highly Annealed Pyrolytic Graphite (HAPG) crystal analyzers setup in a Von Hamos geometry for the simultaneous detection of collective and non-collective x-ray scattering, as well as x-ray fluorescence (XRF) spectroscopy. Using the two-color beam mode at SACLA , we present simultaneous XRTS, XRF, and XRD measurements from copper, aluminum, and nickel foils. These results establish the viability of high-precision XRTS measurements at SACLA and demonstrate a flexible platform for future studies of isochorically heated matter, enabling investigations of non-equilibrium electron thermalization and ultrafast electron dynamics under extreme conditions.