Domenico Formica

Prof. Domenico Formica

Neurophysiology and Neuroengineering of Human-Technology Interaction research unit, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21-00128 Rome, Italy
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2014 in Nature Reviews Neurology
Verified
Journal Article
Closed access
PDF file
GPGiovanni Di Pino
Giovanni Di Pino
GPGiovanni Pellegrino
Giovanni Pellegrino
Giovanni AssenzaGiovanni Assenza
Giovanni Assenza
FCFioravante Capone
Fioravante Capone
Florinda FerreriFlorinda Ferreri
Florinda Ferreri
VLVincenzo Di Lazzaro
Vincenzo Di Lazzaro

13 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JTJacopo Tosi
Jacopo Tosi
Fabrizio TaffoniFabrizio Taffoni
Fabrizio Taffoni
MSMarco Santacatterina
Marco Santacatterina
RSRoberto Sannino
Roberto Sannino
Domenico FormicaDomenico Formica
Domenico Formica
Small, compact and embedded sensors are a pervasive technology in everyday life for a wide number of applications (e.g., wearable devices, domotics, e-health systems, etc.). In this context, wireless transmission plays a key role, and among available solutions, Bluetooth Low Energy (BLE) is gaining more and more popularity. BLE merges together good performance, low-energy consumption and widespread diffusion. The aim of this work is to review the main methodologies adopted to investigate BLE performance. The first part of this review is an in-depth description of the protocol, highlighting the main characteristics and implementation details. The second part reviews the state of the art on BLE characteristics and performance. In particular, we analyze throughput, maximum number of connectable sensors, power consumption, latency and maximum reachable range, with the aim to identify what are the current limits of BLE technology. The main results can be resumed as follows: throughput may theoretically reach the limit of ~230 kbps, but actual applications analyzed in this review show throughputs limited to ~100 kbps; the maximum reachable range is strictly dependent on the radio power, and it goes up to a few tens of meters; the maximum number of nodes in the network depends on connection parameters, on the network architecture and specific device characteristics, but it is usually lower than 10; power consumption and latency are largely modeled and analyzed and are strictly dependent on a huge number of parameters. Most of these characteristics are based on analytical models, but there is a need for rigorous experimental evaluations to understand the actual limits.

18 October 2013 in Sensors
Verified
Journal Article
Open access
PDF file
Fabrizio TaffoniFabrizio Taffoni
Fabrizio Taffoni
Domenico FormicaDomenico Formica
Domenico Formica
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
GPGiovanni Di Pino
Giovanni Di Pino
Emiliano SchenaEmiliano Schena
Emiliano Schena
During last decades, Magnetic Resonance (MR)—compatible sensors based on different techniques have been developed due to growing demand for application in medicine. There are several technological solutions to design MR-compatible sensors, among them, the one based on optical fibers presents several attractive features. The high elasticity and small size allow designing miniaturized fiber optic sensors (FOS) with metrological characteristics (e.g., accuracy, sensitivity, zero drift, and frequency response) adequate for most common medical applications; the immunity from electromagnetic interference and the absence of electrical connection to the patient make FOS suitable to be used in high electromagnetic field and intrinsically safer than conventional technologies. These two features further heightened the potential role of FOS in medicine making them especially attractive for application in MRI. This paper provides an overview of MR-compatible FOS, focusing on the sensors employed for measuring physical parameters in medicine (i.e., temperature, force, torque, strain, and position). The working principles of the most promising FOS are reviewed in terms of their relevant advantages and disadvantages, together with their applications in medicine.

22 April 2004 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
Domenico FormicaDomenico Formica
Domenico Formica
SSSergio Silvestri
Sergio Silvestri
The literature on biological effects of magnetic and electromagnetic fields commonly utilized in magnetic resonance imaging systems is surveyed here. After an introduction on the basic principles of magnetic resonance imaging and the electric and magnetic properties of biological tissues, the basic phenomena to understand the bio-effects are described in classical terms. Values of field strengths and frequencies commonly utilized in these diagnostic systems are reported in order to allow the integration of the specific literature on the bio-effects produced by magnetic resonance systems with the vast literature concerning the bio-effects produced by electromagnetic fields. This work gives an overview of the findings about the safety concerns of exposure to static magnetic fields, radio-frequency fields, and time varying magnetic field gradients, focusing primarily on the physics of the interactions between these electromagnetic fields and biological matter. The scientific literature is summarized, integrated, and critically analyzed with the help of authoritative reviews by recognized experts, international safety guidelines are also cited.

14 September 2015 in Biosensors
Verified
Journal Article
Open access
PDF file
MCMarco Ciocchetti
Marco Ciocchetti
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
Michele Arturo CaponeroMichele Arturo Caponero
Michele Arturo Caponero
APAndrea Polimadei
Andrea Polimadei
Emiliano SchenaEmiliano Schena
Emiliano Schena
Continuous respiratory monitoring is important to assess adequate ventilation. We present a fiber optic-based smart textile for respiratory monitoring able to work during Magnetic Resonance (MR) examinations. The system is based on the conversion of chest wall movements into strain of two fiber Bragg grating (FBG) sensors, placed on the upper thorax (UT). FBGs are glued on the textile by an adhesive silicon rubber. To increase the system sensitivity, the FBGs positioning was led by preliminary experiments performed using an optoelectronic system: FBGs placed on the chest surface experienced the largest strain during breathing. System performances, in terms of respiratory period (TR), duration of inspiratory (TI) and expiratory (TE) phases, as well as left and right UT volumes, were assessed on four healthy volunteers. The comparison of results obtained by the proposed system and an optoelectronic plethysmography highlights the high accuracy in the estimation of TR, TI, and TE: Bland-Altman analysis shows mean of difference values lower than 0.045 s, 0.33 s, and 0.35 s for TR, TI, and TE, respectively. The mean difference of UT volumes between the two systems is about 8.3%. The promising results foster further development of the system to allow routine use during MR examinations.Continuous respiratory monitoring is important to assess adequate ventilation. We present a fiber optic-based smart textile for respiratory monitoring able to work during Magnetic Resonance (MR) examinations. The system is based on the conversion of chest wall movements into strain of two fiber Bragg grating (FBG) sensors, placed on the upper thorax (UT). FBGs are glued on the textile by an adhesive silicon rubber. To increase the system sensitivity, the FBGs positioning was led by preliminary experiments performed using an optoelectronic system: FBGs placed on the chest surface experienced the largest strain during breathing. System performances, in terms of respiratory period (TR), duration of inspiratory (TI) and expiratory (TE) phases, as well as left and right UT volumes, were assessed on four healthy volunteers. The comparison of results obtained by the proposed system and an optoelectronic plethysmography highlights the high accuracy in the estimation of TR, TI, and TE: Bland-Altman analysis shows mean of difference values lower than 0.045 s, 0.33 s, and 0.35 s for TR, TI, and TE, respectively. The mean difference of UT volumes between the two systems is about 8.3%. The promising results foster further development of the system to allow routine use during MR examinations.

19 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Domenico FormicaDomenico Formica
Domenico Formica
SSSergio Silvestri
Sergio Silvestri
Emiliano SchenaEmiliano Schena
Emiliano Schena
Among all the vital signs, respiratory rate remains the least measured in several scenarios, mainly due to the intrusiveness of the sensors usually adopted. For this reason, all contactless monitoring systems are gaining increasing attention in this field. In this paper, we present a measuring system for contactless measurement of the respiratory pattern and the extraction of breath-by-breath respiratory rate. The system consists of a laptop’s built-in RGB camera and an algorithm for post-processing of acquired video data. From the recording of the chest movements of a subject, the analysis of the pixel intensity changes yields a waveform indicating respiratory pattern. The proposed system has been tested on 12 volunteers, both males and females seated in front of the webcam, wearing both slim-fit and loose-fit t-shirts. The pressure-drop signal recorded at the level of nostrils with a head-mounted wearable device was used as reference respiratory pattern. The two methods have been compared in terms of mean of absolute error, standard error, and percentage error. Additionally, a Bland–Altman plot was used to investigate the bias between methods. Results show the ability of the system to record accurate values of respiratory rate, with both slim-fit and loose-fit clothing. The measuring system shows better performance on females. Bland–Altman analysis showed a bias of −0.01 breaths · min − 1 , with respiratory rate values between 10 and 43 breaths · min − 1 . Promising performance has been found in the preliminary tests simulating tachypnea.