14 September 2015 in Biosensors
Verified
Journal Article
Open access
PDF file
MCMarco Ciocchetti
Marco Ciocchetti
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
Michele Arturo CaponeroMichele Arturo Caponero
Michele Arturo Caponero
APAndrea Polimadei
Andrea Polimadei
Emiliano SchenaEmiliano Schena
Emiliano Schena
Continuous respiratory monitoring is important to assess adequate ventilation. We present a fiber optic-based smart textile for respiratory monitoring able to work during Magnetic Resonance (MR) examinations. The system is based on the conversion of chest wall movements into strain of two fiber Bragg grating (FBG) sensors, placed on the upper thorax (UT). FBGs are glued on the textile by an adhesive silicon rubber. To increase the system sensitivity, the FBGs positioning was led by preliminary experiments performed using an optoelectronic system: FBGs placed on the chest surface experienced the largest strain during breathing. System performances, in terms of respiratory period (TR), duration of inspiratory (TI) and expiratory (TE) phases, as well as left and right UT volumes, were assessed on four healthy volunteers. The comparison of results obtained by the proposed system and an optoelectronic plethysmography highlights the high accuracy in the estimation of TR, TI, and TE: Bland-Altman analysis shows mean of difference values lower than 0.045 s, 0.33 s, and 0.35 s for TR, TI, and TE, respectively. The mean difference of UT volumes between the two systems is about 8.3%. The promising results foster further development of the system to allow routine use during MR examinations.Continuous respiratory monitoring is important to assess adequate ventilation. We present a fiber optic-based smart textile for respiratory monitoring able to work during Magnetic Resonance (MR) examinations. The system is based on the conversion of chest wall movements into strain of two fiber Bragg grating (FBG) sensors, placed on the upper thorax (UT). FBGs are glued on the textile by an adhesive silicon rubber. To increase the system sensitivity, the FBGs positioning was led by preliminary experiments performed using an optoelectronic system: FBGs placed on the chest surface experienced the largest strain during breathing. System performances, in terms of respiratory period (TR), duration of inspiratory (TI) and expiratory (TE) phases, as well as left and right UT volumes, were assessed on four healthy volunteers. The comparison of results obtained by the proposed system and an optoelectronic plethysmography highlights the high accuracy in the estimation of TR, TI, and TE: Bland-Altman analysis shows mean of difference values lower than 0.045 s, 0.33 s, and 0.35 s for TR, TI, and TE, respectively. The mean difference of UT volumes between the two systems is about 8.3%. The promising results foster further development of the system to allow routine use during MR examinations.

6 August 2015 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
DPDavide Polito
Davide Polito
Michele Arturo CaponeroMichele Arturo Caponero
Michele Arturo Caponero
APAndrea Polimadei
Andrea Polimadei
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Emiliano SchenaEmiliano Schena
Emiliano Schena
Temperature distribution monitoring in tissue undergoing laser ablation (LA) could be beneficial for improving treatment outcomes. Among several thermometric techniques employed in LA, fiber Bragg grating (FBG) sensors show valuable characteristics, although their sensitivity to strain entails measurement error for patient respiratory movements. Our work describes a solution to overcome this issue by housing an FBG in a surgical needle. The metrological properties of the probes were assessed in terms of thermal sensitivity (0.027 nm °C−1 versus 0.010 nm °C−1 for epoxy liquid encapsulated probe and thermal paste one, respectively) and response time (about 100 ms) and compared with properties of nonencapsulated FBG (sensitivity of 0.010 nm °C−1, response time of 43 ms). The error due to the strain caused by liver movements, simulating a typical respiratory pattern, was assessed: the strain induces a probes output error less than 0.5 °C, which is negligible when compared to the response of nonencapsulated FBG (2.5 °C). The metallic needle entails a measurement error, called artifact, due to direct absorption of the laser radiation. The analysis of the artifact was performed by employing the probes for temperature monitoring on liver undergoing LA. Experiments were performed at two laser powers (i.e., 2 W and 4 W) and at nine distances between the probes and the laser applicator. The artifact decreases with the distance and increases with the power: it exceeds 10 °C at 4 W, when the encapsulated probes are placed at 3.6 mm and 0 deg from the applicator, and it is lower than 1 °C for distance higher than 5 mm and angle higher than 30 deg.

12 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
RDRosaria D'Amato
Rosaria D'Amato
APAndrea Polimadei
Andrea Polimadei
GTGaetano Terranova
Gaetano Terranova
Michele Arturo CaponeroMichele Arturo Caponero
Michele Arturo Caponero
In this work, we report novel relative humidity sensors realized by functionalising fibre Bragg gratings with chitosan, a moisture-sensitive biopolymer never used before for this kind of fibre optic sensor. The swelling capacity of chitosan is fundamental to the sensing mechanism. Different samples were fabricated, testing the influence of coating design and deposition procedure on sensor performance. The sensitivity of the sensors was measured in an airtight humidity-controlled chamber using saturated chemical salt solutions. The best result in terms of sensitivity was obtained for a sensor produced on filter paper substrate. Tests for each design were performed in the environment, lasted several days, and all designs were independently re-tested at different seasons of the year. The produced sensors closely followed the ambient humidity variation common to the 24-h circadian cycle.

20 April 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
DPDavide Paloschi
Davide Paloschi
APAndrea Polimadei
Andrea Polimadei
Sanzhar KorganbayevSanzhar Korganbayev
Sanzhar Korganbayev
VOValerio Orsetti
Valerio Orsetti
CMCristina Mazzotta
Cristina Mazzotta
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
Embedding optical fibers with fiber Bragg grating (FBG) sensors in 3D-printed samples can effectively facilitate the systematic use of smart materials in many fields such as civil, bio-medical and soft robotics applications. The aim of the study is to analyze different combinations of filament materials and FBG coatings, and to assess their metrological characteristics. Eighteen samples are fabricated and tested under different mechanical and thermal conditions. The repeated tests allow to perform an evaluation of the measurement repeatability for each sample, along with an analysis of the samples sensitivity. The filaments employed are acrylonitrile butadiene styrene (ABS), polylactic acid (PLA), and thermoplastic polyurethane (TPU). The fiber coatings are acrylate, Ormocer® and polyimide. The fiber coating has no significative influence on the performance of the sensors. The tests for temperature sensitivity highlight a good performance of ABS (116 pm/°C) and TPU samples (32 pm/°C) up to 60 °C, whereas the fabricated PLA samples (139 pm/°C for polyimide, 55 pm/°C for acrylate, 14 pm/°C for Ormocer®) cannot be used above 40 °C. The tests for strain sensitivity in axial elongation show an average sensitivity of 3.049 nm/mm for ABS, 1.991 nm/mm for PLA, 3.726 nm/mm for TPU. The bending tests show that all specimens materials have different sensitivity to elongation (2.994 nm/mm for ABS, 0.668 nm/mm for PLA, 0.149 nm/mm for TPU). Only for acrylate in PLA samples an effective difference for bending sensitivity resulted (1.241 nm/mm for the acrylate coating vs 2.366 nm/mm for the other coatings).

22 January 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
GCGabriele Colombo
Gabriele Colombo
SASayyed Ashkan Adibi
Sayyed Ashkan Adibi
MBMarco Breschi
Marco Breschi
Michele Arturo CaponeroMichele Arturo Caponero
Michele Arturo Caponero
ACAntonio Castaldo
Antonio Castaldo
Gianluca De MarziGianluca De Marzi
Gianluca De Marzi
In this article, we report the results from two test campaigns conducted to evaluate the feasibility of implementing a commercially available optical fiber-based distributed sensing technology for Quench Detection (QD) purposes. We successfully characterized the temperature response and sensitivity achievable by this technique when using a bare single mode fiber within a cryogen free cooling system operating in the temperature range from 4 K to 300 K. A fiber was also incorporated into a sample featuring an High-Temperature Superconductor (HTS) stack mounted onto an extruded Aluminum slotted-core cable. Quench-like events were triggered by locally lowering the critical current using the magnetic field produced by a set of permanent magnets placed near the center of the stack. The experiments were carried out at 77 K by cooling the sample through the central channel of the Aluminum core with a forced flow of liquid nitrogen. The test results indicate the viability of this technology as a suitable alternative for QD in long-length HTS cables and motivate further work to develop distributed sensing systems able to work in the conditions foreseen for HTS fusion coils.

30 January 2025 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
AMAndrea Masi
Andrea Masi
GCG. Colombo
G. Colombo
MSM. De Stasio
M. De Stasio
MBMarco Breschi
Marco Breschi
Michele Arturo CaponeroMichele Arturo Caponero
Michele Arturo Caponero
Gianluca De MarziGianluca De Marzi
Gianluca De Marzi
The high environmental electromagnetic noise characteristic of fusion reactors and low quench propagation velocity of HTS conductors designed for such applications drive the quest for quench detection solutions alternative to voltage methods. Techniques based on optical fiber sensors represent a promising solution, but their integration in cables is not straightforward due to their intrinsic fragility. In this work, we report on the production and testing of an HTS aluminum slotted core cable exploiting a BRAided STack (BRAST) of REBCO tapes. The braid also encloses two stainless steel capillaries containing fiber-optic sensors responsible for monitoring the stack temperature. The sample was subjected to quench experiments at liquid nitrogen temperature, evaluating its electrical and thermal response. The experimental results demonstrate that the integration of optical sensors within the BRAST enables monitoring of stack temperature and detection of quench events, highlighting the greater sensitivity achieved by detecting temperature changes directly on the superconducting stack compared with sensors placed on the outer jacket. This approach represents thus a simple and effective solution for the integration of optical sensors in fusion cables.