Quanquan Wu

Dr. Quanquan Wu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
DSDinglian Shi
Dinglian Shi
Jianlong LiJianlong Li
Jianlong Li
YDYongnan Du
Yongnan Du
QWQuanquan Wu
Quanquan Wu
Shan HuangShan Huang
Shan Huang
DWDaishe Wu
Daishe Wu
To study the effect of air humidity on particle filtration performance, the Particle Flow Code (PFC) calculation program was used to numerically simulate the formation process of filter cake. The effects of relative air humidity on the deposition morphology, porosity and filtration resistance characteristics of the filter cake were revealed. The results show that relative humidity (RH) is mainly reflected in the density and surface viscosity of the particles. It was found that the higher the relative humidity, the higher the particle moisture content, the greater the density, and the greater the surface viscosity. With an increase in the particle density or with a decrease in the viscosity, the bridging phenomenon of particle deposition became more obvious; the dendritic deposition phenomenon became weaker; and, therefore, the filter cake structure became denser; the porosity decreased; and the total filtration resistance increased. As the humidity changed, the actual density and viscosity of the particles changed simultaneously with different degrees, which caused different variation trends of the filter cake characteristics. Three different types of particles, DM828 (Starch), PVA1788 (Polyvinyl Alcohol) and Polyacrylamide (Polyacrylic acid), were selected for comparison. For the studied PVA1788 and Polyacrylamide particles, with an increase in relative humidity, the porosity of the filter cake increased monotonously, while the total filtration resistance decreased monotonously. For DM828 particles, the cake porosity first decreased and then increased, and the total filtration resistance first increased and then decreased, with an inflection point at 30% RH. By combining these results with existing reports, three kinds of variations of the filtration performance with humidity could be determined: (1) as the humidity increased, the filtration resistance first increased and then decreased; (2) the filtration resistance decreased; and (3) the filtration resistance increased.

20 July 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
QWQuanquan Wu
Quanquan Wu
XLXiaohai Li
Xiaohai Li
ZXZhenqiang Xing
Zhenqiang Xing
QKQin Kuang
Qin Kuang
Jianlong LiJianlong Li
Jianlong Li
DWDaishe Wu
Daishe Wu
The re-deposition of detached dust during online pulse-jet cleaning is an important issue encountered during filter regeneration. To reduce dust re-deposition, multi-pulsing jet cleaning schemes were designed and experimentally tested. A pilot-scale pulse-jet cleaning dust collector was built with one vertically installed pleated filter cartridge. The effects of pulse duration and interval on the pulse pressure were tested, and the dust re-deposition rate and mechanism were studied and analyzed. It was found that, for the single-pulsing jet, the pulse duration had a critical value of approximately 0.080 s in this test, above which the pulse pressure remained at approximately 0.75 kPa and did not increase further. For the multi-pulsing jet with a small pulse interval (less than approximately 0.10 s), the pulse flows superimposed and reached a higher pulse pressure with a slight inhibition of dust re-deposition. For the multi-pulsing jet with a long pulse interval (over 0.15 s), dust re-deposition was clearly inhibited. The re-deposition rate decreased from 63.8% in the single-pulsing scheme to 24.4% in the multi (five)-pulsing scheme with the same total pulse duration of 0.400 s. The multi-pulsing scheme lengthens the duration of reverse pulse flow, resulting in more elapsed time for the detached dust to freely fall, and inhibiting the re-deposition of dust. The elapsed time in the five-pulsing jet scheme with the recommended pulse duration of 0.080 s and interval of 0.25 s was 2.8 times higher than that of the single-pulsing jet with the same total pulse duration.

26 March 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
BYBin Yang
Bin Yang
Jianwu ChenJianwu Chen
Jianwu Chen
Jianlong LiJianlong Li
Jianlong Li
WXWenjun Xie
Wenjun Xie
QWQuanquan Wu
Quanquan Wu
ZJZhongan Jiang
Zhongan Jiang
For workplaces where the dust cakes have high viscosity, it is difficult to peel the dust cake from the surface of the dust filter cartridge. The problem of poor dust removal restricts the efficient and stable operation of the dust collector. This study proposes a diffuser nozzle to improve the pulsed-jet cleaning performance of cone filter cartridges. Through numerical modeling, the study investigates the improvement of pulsed-jet velocity and pressure by the diffuser nozzle, explores the influence of the diffuser angle (θ) and diffuser distance (D) on the jet field of the cone filter cartridge core, and compares the pulsed-jet intensity and uniformity of the dust removal filter cartridge. The findings show that the diffuser nozzle with appropriate parameters is conducive to enhancing the divergence and entrainment of the jet airflow, reducing the airflow velocity in the filter cartridge opening area and increasing the static pressure, while also increasing the airflow entrainment. The pulsed-jet intensity and uniformity, especially the pulsed-jet intensity in the upper part of the filter cartridge, vary significantly with θ or D, and the action mechanisms of θ or D are obtained. Under the recommended diffuser nozzle parameters (θ = 70° and D = 40 mm), the pulsed-jet intensity is 1086 Pa, which is 5.4% higher than that under the condition of the common round nozzle; the uniformity coefficient is 0.14, which is 60.0% better than that under the condition of the common round nozzle. For the upper part of the filter cartridge, the pulsed-jet intensity is 1.39 times that with the common nozzle. The result is significant as it offers a guide for improving the pulse-jet cleaning of dust removal filter cartridges.

14 December 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
QWQuanquan Wu
Quanquan Wu
XWXianglian Wang
Xianglian Wang
KJKai Ji
Kai Ji
HQHaibing Qiu
Haibing Qiu
WFWeiwei Feng
Weiwei Feng
DWDaishe Wu
Daishe Wu
Exposure to high concentrations of fine particles (PM2.5) with toxic metals can have significant health effects, especially during the Chinese spring festival (CSF), due to the large amount of fireworks’ emissions. Few studies have focused on the potential health impact of PM2.5 pollution in small cities in China during the 2020 CSF, which coincided with the COVID-19 outbreak that posed a huge challenge to the environment and obvious health issues to countries around the world. We examined the characteristics of PM2.5, including carbonaceous matter and elements, for three intervals during the 2020 CSF in Taizhou, identified the sources and evaluated the health risks, and compared them with those of 2018. The results showed that PM2.5 increased by 13.20% during the 2020 CSF compared to those in the 2018 CSF, while carbonaceous matter (CM) and elements decreased by 39.41% and 53.84%, respectively. The synergistic effects of emissions, chemistry, and transport may lead to increased PM2.5 pollution, while the lockdown measures contributed to the decrease in CM and elements during the 2020 CSF. Fe, Mn, and Cu were the most abundant elements in PM2.5 in both years, and As and Cr(VI) should be of concern as their concentrations in both years exceeded the NAAQS guideline values. Industry, combustion, and mineral/road dust sources were identified by PCA in both years, with a 5.87% reduction in the contribution from industry in 2020 compared to 2018. The noncarcinogenic risk posed by As, Co, Mn, and Ti in 2018 and As and Mn in 2020 was significant. The carcinogenic risk posed by As, Cr(VI), and Pb exceeded the accepted precautionary limit (1 × 10−6) in both years. Mn was the dominant contributor to the total noncarcinogenic risks, while Cr(VI) showed the largest excessive cancer risks posed by metals in PM2.5, implying its associated source, industry, was the greatest risk to people in Taizhou after exposure to PM2.5. Despite the increase in PM2.5 mass concentration, the health impacts were reduced by the lockdown policy implemented in Taizhou during the 2020 CSF compared to 2018. Our study highlights the urgent need to consider the mitigation of emissions in Taizhou and regional joint management efforts based on health protection objectives despite the rough source apportionment by PCA.

24 August 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
ZXZhenqiang Xing
Zhenqiang Xing
GWGang Wang
Gang Wang
JGJiace Guo
Jiace Guo
WLWenyong Lu
Wenyong Lu
YZYi Zhao
Yi Zhao
Jianlong LiJianlong Li
Jianlong Li
There is a problem with the insufficient cleaning of the dust filter cartridge by the pulsed-jet cleaning method. This paper examines the improvement in the pulse-jet performance of cone filter cartridges achieved by using an annular-slit nozzle. Off-line pulse jet experiments were conducted to study the influence of initial compressed air pressure, jet distance, and Venturi tube on injection pressure. This paper compared the filtration performance of conventional nozzles versus slit nozzles by conducting an online dust filtration-cleaning experiment and investigating the effect of a Venturi tube. The results demonstrated that the jet produced by the slit nozzle had a bigger surface area in contact with the surrounding air, enhancing the entrainment effect, boosting the overall pulsed-jet pressure, and significantly elevating the pressure in the upper and middle section of the cartridge, particularly in the upper section. In both common nozzle and slit nozzle cases, the pulsed-jet intensity initially increased and then decreased with the jet distance. The corresponding optimal jet distances were 500 mm and 400 mm, respectively. The slit nozzle provoked an increment of 16% and 44% in the pulsed-jet intensity and uniformity (to 619 Pa and 0.19), respectively. And there was an 8% reduction in residual pressure drop, a 6% improvement in fallen dust mass, and a 7% improvement in comprehensive filtration performance. The fallen dust mass produced by a single cleaning of the slit nozzle was 0.64 kg and the comprehensive filtration performance was 0.18. While the addition of a Venturi tube improved the cleaning of the filter cartridge, it also led to a higher filtration pressure drop in the dust collector and reduced comprehensive filtration performance.