Zhenqiang Xing

Mr. Zhenqiang Xing


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
QWQing Wu
Qing Wu
ZXZhenqiang Xing
Zhenqiang Xing
DCDejun Chen
Dejun Chen
Jianwu ChenJianwu Chen
Jianwu Chen
BYBin Yang
Bin Yang
DWDaishe Wu
Daishe Wu
The adhesion of dust particles on the surface of the dust collector tends to cause great resistance to the dust collector and affects the operating efficiency. In order to visualize particles in the filtration process and to grasp the mechanism of particle viscosity and sphericity on filtration performance, a numerical simulation study was conducted to investigate the deposition behavior of particles during filtration, employing FLUENT-EDEM coupling technology. By examining the deposition process, the role of particle characteristics on dust behavior within the entire filtration system was elucidated. The effects of varying particle surface energy and particle sphericity on filtration pressure drop and cake porosity were analyzed. The findings reveal that under the force of the air, particles on the surface of the filter membrane experience compaction, leading to a reduction in the porosity of the formed cake layer. The diminution of porosity serves to impede the air, consequently augmenting the pressure drop across the filtration system and hindering the operational efficacy of the dust collector. As the surface energy of the particles increases, the adhesive forces between particles are intensified, leading to an elevation in the porosity of the cake layer and a subsequent decrease in the pressure drop. When the surface energy of the particles is increased from 0.01 J/m2 to 0.04 J/m2, the porosity experiences a modest increase of only 9.1%, yet the pressure drop is significantly reduced by half, amounting to a decrease of 1594 Pa. Under high particle surface energy, as filtration air velocity increases, particles are compressed, resulting in a decrease in cake porosity and an increase in pressure drop. Concurrently, our findings indicate that as the sphericity of particles increases, their surfaces become increasingly smooth which in turn results in a decreased porosity of the cake layer and, consequently, an elevation in the filtration pressure drop.

20 July 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
QWQuanquan Wu
Quanquan Wu
XLXiaohai Li
Xiaohai Li
ZXZhenqiang Xing
Zhenqiang Xing
QKQin Kuang
Qin Kuang
Jianlong LiJianlong Li
Jianlong Li
DWDaishe Wu
Daishe Wu
The re-deposition of detached dust during online pulse-jet cleaning is an important issue encountered during filter regeneration. To reduce dust re-deposition, multi-pulsing jet cleaning schemes were designed and experimentally tested. A pilot-scale pulse-jet cleaning dust collector was built with one vertically installed pleated filter cartridge. The effects of pulse duration and interval on the pulse pressure were tested, and the dust re-deposition rate and mechanism were studied and analyzed. It was found that, for the single-pulsing jet, the pulse duration had a critical value of approximately 0.080 s in this test, above which the pulse pressure remained at approximately 0.75 kPa and did not increase further. For the multi-pulsing jet with a small pulse interval (less than approximately 0.10 s), the pulse flows superimposed and reached a higher pulse pressure with a slight inhibition of dust re-deposition. For the multi-pulsing jet with a long pulse interval (over 0.15 s), dust re-deposition was clearly inhibited. The re-deposition rate decreased from 63.8% in the single-pulsing scheme to 24.4% in the multi (five)-pulsing scheme with the same total pulse duration of 0.400 s. The multi-pulsing scheme lengthens the duration of reverse pulse flow, resulting in more elapsed time for the detached dust to freely fall, and inhibiting the re-deposition of dust. The elapsed time in the five-pulsing jet scheme with the recommended pulse duration of 0.080 s and interval of 0.25 s was 2.8 times higher than that of the single-pulsing jet with the same total pulse duration.

18 October 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
QWQuanquan Wu
Quanquan Wu
ZXZhenqiang Xing
Zhenqiang Xing
YXYufan Xu
Yufan Xu
YTYuanbing Tang
Yuanbing Tang
YLYangyang Li
Yangyang Li
Jianlong LiJianlong Li
Jianlong Li
The new type of gold cone filter cartridge has dual functions of increasing filter area and enhancing pulsed-jet cleaning, but the issue of patchy cleaning remains to be addressed. This study further enhances the pulsed-jet cleaning performance of cone filter cartridges by employing a porous diffusion nozzle. The temporal and spatial distributions of pulse jet velocity and pressure under the condition of porous nozzles were investigated through numerical modeling. The variation law of pressure on the side wall of the filter cartridge was analyzed. The influence of jet distance of porous nozzles on pulsed-jet pressure and pulsed-jet uniformity was experimentally investigated. Dust filtration and cleaning experiments were conducted, and the filtration pressure drop, dust emission concentration, and comprehensive filtration performance were compared. It was found that the airflow jetted by the porous diffusion nozzle is more divergent than that of the common round nozzle. This results in a larger entrainment of the jet stream, a milder collision of the jet stream with the cartridge cone, and a slower overall velocity reduction. More airflow is generated into the filter cartridge and accumulated; the accumulated static pressure covers a larger range of the upper section of the filter cartridge, with a longer duration of static pressure. In the online dust filtration and cleaning experiment, compared with the condition of the common round nozzle, the porous nozzle can reduce the residual pressure drop by 27.0%, increase the filtration cleaning interval by a factor of 3.80, reduce the average dust emission concentration by 45.2%, and increase the comprehensive performance index QF by 5.2%. The research conclusions can provide references for the design and optimization of industrial filter cartridge dust collectors.

24 August 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
ZXZhenqiang Xing
Zhenqiang Xing
GWGang Wang
Gang Wang
JGJiace Guo
Jiace Guo
WLWenyong Lu
Wenyong Lu
YZYi Zhao
Yi Zhao
Jianlong LiJianlong Li
Jianlong Li
There is a problem with the insufficient cleaning of the dust filter cartridge by the pulsed-jet cleaning method. This paper examines the improvement in the pulse-jet performance of cone filter cartridges achieved by using an annular-slit nozzle. Off-line pulse jet experiments were conducted to study the influence of initial compressed air pressure, jet distance, and Venturi tube on injection pressure. This paper compared the filtration performance of conventional nozzles versus slit nozzles by conducting an online dust filtration-cleaning experiment and investigating the effect of a Venturi tube. The results demonstrated that the jet produced by the slit nozzle had a bigger surface area in contact with the surrounding air, enhancing the entrainment effect, boosting the overall pulsed-jet pressure, and significantly elevating the pressure in the upper and middle section of the cartridge, particularly in the upper section. In both common nozzle and slit nozzle cases, the pulsed-jet intensity initially increased and then decreased with the jet distance. The corresponding optimal jet distances were 500 mm and 400 mm, respectively. The slit nozzle provoked an increment of 16% and 44% in the pulsed-jet intensity and uniformity (to 619 Pa and 0.19), respectively. And there was an 8% reduction in residual pressure drop, a 6% improvement in fallen dust mass, and a 7% improvement in comprehensive filtration performance. The fallen dust mass produced by a single cleaning of the slit nozzle was 0.64 kg and the comprehensive filtration performance was 0.18. While the addition of a Venturi tube improved the cleaning of the filter cartridge, it also led to a higher filtration pressure drop in the dust collector and reduced comprehensive filtration performance.

19 August 2026 in Atmosphere
Verified
Journal Article
Open access
PDF file
ZXZhenqiang Xing
Zhenqiang Xing
In the mining process of shallow-buried and close-distance coal seam groups in western China, the interconnected collapse fractures between the overlying goaf and the surface form large-area composite goafs, which aggravate surface air leakage and elevate oxygen levels within the goaf. This, in turn, leads to hazardous conditions such as CO over-limits and O2 deficiency at the working face’s return air corner, which seriously threatens the respiratory health of underground operators and the safe production of mines. Taking the 104 working face of a coal mine in Shenfu-Dongsheng Mining Area as the engineering background, this paper comprehensively adopts SF6 tracer gas test, fuzzy cluster analysis, and CFD numerical simulation methods to systematically study the distribution characteristics of three-dimensional air leakage channels in composite goafs and their influence mechanism on gas migration in goafs, and proposes a dynamic pressure equalization ventilation (PEV) regulation technology system. The research results show that a multi-dimensional three-dimensional air leakage channel of “surface-interlayer-own layer-roadway” exists in the research area, in which the surface fracture air leakage velocity is about 0.068 m/s, and the interlayer and internal goaf air leakage velocity is about 0.384 m/s. The atmospheric pressure difference between the working face and the surface is the main controlling factor inducing the O2 deficiency disaster of the working face. Every 100 Pa change in atmospheric pressure difference causes an O2 concentration fluctuation of about 0.30% at the return air corner, and the critical pressure difference for activating PEV is determined to be 300 Pa. Setting the PEV regulation point at the return air outlet of the working face and adopting the combined dynamic regulation system of fans and air windows can realize accurate pressure balance between the working face and the overlying composite goaf.