Cristian Moldovan

Dr. Cristian Moldovan


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CMCristian Moldovan
Cristian Moldovan
CSCarmen Sticlaru
Carmen Sticlaru
Bearings in general, and in this case rotational bearings, are important elements in many machines. The main objective of this study was to find out the load-bearing capacity of 3D-printed gear bearings under various rotational speeds, test the bearings to failure and estimate their lifetime. An interesting note on the gear bearing is its uncommon geometric configuration, because the rolling elements are gears, which allows for a rolling-sliding motion between the constituting elements, minimizing the sliding effect. The material used is PLA (poly lactic acid), a common thermoplastic polyester, and the printing technology was FDM (fused deposition modeling). Considering the PLA’s temperature sensitivity, this was also monitored but had no influence on the failure of the bearing, as experiments show. The rotational speed range for the experiment is 250–1500 RPM (revolutions per minute) in increments of 250 RPM, and the loads are 18 N (Newton) and 45 N for a gear bearing with 51 mm diameter and 15 mm thickness. The results of this study can be used as a reference for application limitations or to design gear bearings using 3D printing methods.

27 September 2024
Verified
Book Chapter
Closed access
PDF file
IPIoan-Emil Popescu
Ioan-Emil Popescu
FFFlorin Florescu
Florin Florescu
CMCristian Moldovan
Cristian Moldovan
DBDorel Buncianu
Dorel Buncianu
ETElida-Gabriela Tulcan
Elida-Gabriela Tulcan
ELErwin-Christian Lovasz
Erwin-Christian Lovasz

19 December 2024 in Reports
Verified
Journal Article
Open access
PDF file
CSCalin Daniel Stefan
Calin Daniel Stefan
CMCristian Moldovan
Cristian Moldovan
Liviu  MarsavinaLiviu Marsavina
Liviu Marsavina
MHMihai Hurmuz
Mihai Hurmuz
ISIuliana Stefan
Iuliana Stefan
Background and Clinical Significance: Since their first introduction in the early 1950s, hip prostheses implants are becoming increasingly reliable; nevertheless, failures can still happen. The focus of this paper is to present a case study on a catastrophic fractured hip prosthesis liner that consequently led to revision surgery and the replacement of the destroyed implant. Case Presentation: The patient was diagnosed with Hodgkin’s lymphoma and had Total Hip Arthroplasty on both legs, but only the right side needed revision due to a fracture in the liner. The patient’s symptoms were a squeaking sound, functional impairment, and pain, and an X-ray showed the extent of the damage. We also present a short review on the mechanisms of liner fracture, focusing strictly on the mechanical aspects of failure. Conclusions: Hip prosthesis implants are not immune to failure. This case highlights the importance of an interdisciplinary approach and emphasizes the need for vigilant postoperative monitoring and the development of predictive tools.

15 December 2023
Verified
Book Chapter
Closed access
PDF file
ELErwin-Christian Lovasz
Erwin-Christian Lovasz
CMCristian Moldovan
Cristian Moldovan
MMMarius Cornel Mateas
Marius Cornel Mateas

1 October 2016 in Mechanisms and Machine Science
Verified
Book Chapter
Closed access
PDF file
CMCristian Moldovan
Cristian Moldovan
DPD. Perju
D. Perju
ELE.-C. Lovasz
E.-C. Lovasz
KMK.-H. Modler
K.-H. Modler
IMI. Maniu
I. Maniu

27 August 2014
Verified
Book Chapter
Closed access
PDF file
ELErwin-Christian Lovasz
Erwin-Christian Lovasz
DPD. Perju
D. Perju
KMK.-H. Modler
K.-H. Modler
CGCorina Mihaela Gruescu
Corina Mihaela Gruescu
DMD. Mărgineanu
D. Mărgineanu
CPCristian Pop
Cristian Pop