Early results from the prospective ESPOIR Trial have indicated excellent results for pulmonary valve replacement using decellularized pulmonary homografts (DPH). A 5-year analysis of ESPOIR Trial patients was performed to provide an insight into the midterm DPH performance. ESPOIR Trial and Registry patients were matched with cryopreserved homografts (CH) patients considering patient age, type of heart defect and previous procedures to present the overall experience with DPH. A total of 121 patients (59 female) were prospectively enrolled (8/2014–12/2016), median age 16.5 years (interquartile range 11.2–29.8), and median DPH diameter 24 mm. One death (73 year-old) occurred during a median follow-up of 5.9 years (5.4–6.4), in addition to 2 perioperative deaths resulting in an overall mortality rate of 2.5%. One case of endocarditis in 637 patient-years was noticed, resulting in an incidence of 0.15% per patient-year. At 5 years, the mean peak gradient was 19.9 mmHg (9.9), mean regurgitation 0.9 (0.6, grade 0–3) and freedom from explantation/any reintervention 97.5% (1.5). The combined DPH cohort, n = 319, comprising both Trial and Registry data, showed significantly better freedom from explantation for DPH 95.5% (standard deviation 1.7) than CH 83.0% (2.8) (P < 0.001) and less structural valve degeneration at 10 years when matched to 319 CH patients [DPH 65.5% (standard deviation 4.4) and CH 47.3% (3.7), P = 0.11]. The 5-year data of the prospective ESPOIR Trial show excellent performance for DPH and low rates of adverse events. ESPOIR Registry data up to 15 years, including a matched comparison with CH, demonstrated statistically significant better freedom from explantation.
1 December 2001 in Archives of Biochemistry and Biophysics
Mechanical composite valve grafts (MCVGs) are the first-line therapy for aortic root replacement in young adults. Decellularized aortic homografts (DAH) present a promising novel alternative due to their lower thrombogenicity. We aimed to compare both treatment options regarding survival and valve-related adverse events. This study was designed as a single-centre retrospective cohort study including patients who underwent root replacement with MCVG or DAH between 2000 and 2022. Urgent or emergent procedures were excluded. The study cohort included 289 patients (MCVG n = 216, DAH n = 73) with a mean age of 48.5 ± 12 years (MCVG 49 ± 12 years vs DAH 47 ± 11 years; P = 0.23) and a median EuroScore II of 1.7% (1.2, 2.6). The 30-day mortality was 1% (n = 3). Cumulative survival at 3 years was 99% for DAH and 94% for MCVG, respectively (P = 0.15). Mean follow-up was 98.9 ± 72.7 months. Bleeding events (n = 14, 6.5%) and thromboembolism (n = 14, 6.5%) were only observed in the MCVG group (P = 0.19 and 0.09, respectively). Four cases (5%) of moderate structural valve deterioration occurred, all in the DAH group (P ≤ 0.001). The cumulative incidence of a composite end point of valve-related adverse events was significantly higher in the MCVG group (P = 0.0295). Aortic root replacement with MCVGs and decellularized aortic homografts showed low mortality in an elective setting. Patients in the homograft cohort demonstrated significantly higher freedom from valve-related adverse events. DAH present a promising treatment option for young patients requiring root replacement; however, data on long-term durability are needed.
Background: decellularized aortic homografts (DAH) represent a promising alternative for aortic valve replacement in young adults due to their low immunogenicity and thrombogenicity. Herein, we report our midterm, single-center experience in adult patients with non-frozen DAH from corlife. Methods: safety, durability, and hemodynamic performance were evaluated according to current guidelines in all consecutive patients who had received a DAH at our center since 03/2016. Results: seventy-three (mean age 47 ± 11 years, 68.4% (n = 50) male) patients were enrolled. The mean diameter of the implanted DAH was 24 ± 2 mm. Mean follow-up was 36 ± 27 months, with a maximum follow-up of 85 months and cumulative follow-up of 215 years. No cases of stenosis were observed, in four (5.5%) cases moderate aortic regurgitation occurred, but no reintervention was required. No cases of early mortality, non-structural dysfunction, reoperation, valve endocarditis, or thrombosis were observed. Freedom from bleeding and thromboembolic events was 100%; freedom from re-intervention was 100%; survival was 98.6% (n = 72). Conclusions: early and mid-term results showed low mortality and 100% freedom from reoperation, thromboembolic events, and bleeding at our center. However, in order for this novel approach to be established as a valid alternative to aortic valve replacement in young patients, long-term data are required.
Objectives: This study aimed to compare the clinical outcomes of mechanical and biological valve prostheses in patients with infective endocarditis presenting with stroke. Methods: Ninety-five adults with infective endocarditis complicated by stroke at baseline who underwent aortic and/or mitral valve replacement were analyzed retrospectively. The primary outcome was a composite outcome of all-cause mortality, ischemic stroke, hemorrhagic stroke, and re-endocarditis. Secondary outcomes included the individual components of the composite outcome and modified Rankin scale deterioration during follow-up. Results: Among the study cohort, 34 patients (35.8%) received mechanical valve prostheses and 61 (64.2%) received biological valve prostheses. Implantation of a mechanical valve prosthesis seems to be associated with a decreased risk of attaining the composite outcome (adjusted HR 0.46, 95% CI 0.22–0.96, and p = 0.037). Analyses of the individual components of the composite outcome showed that implantation of a mechanical valve prosthesis might not be associated with an increased risk of ischemic stroke, hemorrhagic stroke, and all-cause mortality during the follow-up period. Further, the risk of re-endocarditis was significantly lower in recipients of a mechanical valve prosthesis (adjusted HR 0.15, 95% CI 0.06–0.77, p = 0.026). Notably, a trend toward decreased risk of modified Rankin scale deterioration throughout the follow-up period was observed in this group (adjusted odds ratio 0.22, 95% CI 0.05–1.02, p = 0.053). Conclusions: Implantation of mechanical valve prostheses in patients presenting with infective endocarditis complicated by stroke seems to be beneficial in terms of a reduced risk of experiencing a composite outcome. Analyses of larger cohorts are required to validate our findings.
27 February 2025 in European Journal of Cardio-Thoracic Surgery