Evidence on long-term clinical outcomes considering suture-securing techniques used for surgical aortic valve replacement is still uncertain. A total of 1405 patients who underwent surgical aortic valve replacement between January 2016 and December 2022 were included and grouped according to the suture-securing technique used (automated titanium fastener versus hand-tied knots). The occurrence of infective endocarditis during follow-up was set as the primary study end-point. As secondary study end-points, stroke, all-cause mortality and a composite outcome of either infective endocarditis, stroke, or all-cause mortality were assessed. The automated titanium fastener was used in 829 (59%) patients, whereas the hand-knot tying technique was used in 576 (41%) patients. The multivariable proportional competing risk regression analysis showed a significantly lower risk of infective endocarditis during follow-up in the automated titanium fastener group (adjusted sub-hazard ratio 0.44, 95% confidence interval 0.20–0.94, P = 0.035). The automated titanium fastener group was not associated with an increased risk of mortality or attaining the composite outcome, respectively (adjusted hazard ratio 0.81, 95% confidence interval 0.60–1.09, P = 0.169; adjusted hazard ratio 0.82, 95% confidence interval 0.63–1.07, P = 0.152). This group was not associated with an increased risk of stroke (adjusted sub-hazard ratio 0.82, 95% confidence interval 0.47–1.45, P = 0.504). Also, a significantly lower rate of early-onset infective endocarditis was observed in the automated titanium fastener group, (0.4% vs 1.4%, P = 0.032). Suture-securing with an automated titanium fastener device appears to be superior compared to the hand-knot tying technique in terms of lower risk of infective endocarditis.
23 January 2024 in Frontiers in Cardiovascular Medicine
Objectives: To date, there is no evidence regarding the safety of automated titanium fastener compared with hand-tied knots for prosthesis fixation in infective endocarditis.Methods: Between January 2016 and December 2022, a total of 220 patients requiring surgery for infective endocarditis were included in this retrospective analysis. The primary study endpoint was re-endocarditis during follow-up. The secondary study endpoints included stroke onset, all-cause mortality, and a composite outcome of either re-endocarditis, stroke, or all-cause mortality during follow-up.Results: Suture-securing with an automated titanium fastener was performed in 114 (51.8%) patients, whereas the conventional technique of hand knot-tying was used in 106 (48.2%) patients. The risk of re-endocarditis was significantly lower in the automated titanium fastener group, as shown in a multivariable proportional competing risk regression model (adjusted sub-hazard ratio 0.33, 95% confidence interval 0.11–0.99, p = 0.048). The multivariable Cox proportional hazards regression analysis showed that the automated titanium fastener group was not associated with an increased risk of stroke-onset or attaining the composite outcome, respectively, (adjusted hazard ratio 0.54, 95% confidence interval 0.27–1.08, p = 0.082), (adjusted hazard ratio 0.65, 95% confidence interval 0.42–1.02, p = 0.061). Also, this group was not associated with an increased risk of all-cause mortality, as demonstrated in the multivariable Poisson regression analysis (adjusted incidence-rate ratio 1.42, 95% confidence interval 0.83–2.42, p = 0.202).Conclusions: The use of automated titanium fastener device seems to be safe for infective endocarditis. Analyses of larger cohorts are required.
6 January 2026 in European Journal of Cardio-Thoracic Surgery
Objectives: This study aimed to assess long-term outcomes of automated titanium fasteners versus hand-tied knots in mitral valve surgery. Methods: In this retrospective, single-centre analysis, 2678 adult patients who underwent mitral valve repair or replacement between November 2008 and November 2024 at the Medical University of Vienna were included. Patients were grouped according to the suture-securing technique used: automated titanium fasteners versus hand-tied knots. The primary endpoint was prosthetic dehiscence (either mitral annuloplasty ring or valve replacement prosthesis) requiring reintervention. Secondary endpoints comprised ischaemic stroke, intracranial bleeding, and all-cause mortality during the follow-up period. Results: Among the study population, 1072 (40%) underwent mitral valve surgery using an automated titanium fastener device, and 1606 (60%) with conventional hand-tied sutures. A total of 31 patients (1.2%) had prosthetic dehiscence during the follow-up period. The risk of prosthetic dehiscence was significantly lower in the automated titanium fastener group in both univariable (crude sub-hazard ratio [sHR] 0.32; 95% confidence interval [CI], 0.12-0.86, P = .023) and multivariable competing risk regression analysis (adjusted sHR 0.34; 95% CI, 0.12-0.91, P = .033). Automated titanium fastener group was not associated with an increased risk of ischaemic stroke (adjusted sHR 0.92; 95% CI, 0.67-1.27, P = .600), intracranial bleeding (adjusted sHR 0.89; 95% CI, 0.52-1.52, P = .675), or all-cause mortality (adjusted hazard ratio 0.93; 95% CI, 0.74-1.18, P = .559). Conclusions: The use of an automated titanium fastener device seems to be associated with a lower risk of prosthetic dehiscence in mitral valve surgery. Due to the limited number of prosthetic dehiscence events and the potential for residual confounding, the results should be interpreted with caution.
Objectives: This study aimed to compare the clinical outcomes of mechanical and biological valve prostheses in patients with infective endocarditis presenting with stroke. Methods: Ninety-five adults with infective endocarditis complicated by stroke at baseline who underwent aortic and/or mitral valve replacement were analyzed retrospectively. The primary outcome was a composite outcome of all-cause mortality, ischemic stroke, hemorrhagic stroke, and re-endocarditis. Secondary outcomes included the individual components of the composite outcome and modified Rankin scale deterioration during follow-up. Results: Among the study cohort, 34 patients (35.8%) received mechanical valve prostheses and 61 (64.2%) received biological valve prostheses. Implantation of a mechanical valve prosthesis seems to be associated with a decreased risk of attaining the composite outcome (adjusted HR 0.46, 95% CI 0.22–0.96, and p = 0.037). Analyses of the individual components of the composite outcome showed that implantation of a mechanical valve prosthesis might not be associated with an increased risk of ischemic stroke, hemorrhagic stroke, and all-cause mortality during the follow-up period. Further, the risk of re-endocarditis was significantly lower in recipients of a mechanical valve prosthesis (adjusted HR 0.15, 95% CI 0.06–0.77, p = 0.026). Notably, a trend toward decreased risk of modified Rankin scale deterioration throughout the follow-up period was observed in this group (adjusted odds ratio 0.22, 95% CI 0.05–1.02, p = 0.053). Conclusions: Implantation of mechanical valve prostheses in patients presenting with infective endocarditis complicated by stroke seems to be beneficial in terms of a reduced risk of experiencing a composite outcome. Analyses of larger cohorts are required to validate our findings.
Background: The Sandwich technique is a commonly adopted method for reinforcing the dissected aortic wall during acute Type A aortic dissection (ATAAD) repair, using either felt or bovine pericardial strips. However, complications such as anastomotic bleeding, distal anastomotic new entry (DANE) and persistent false lumen (PFL) remain major challenges. This study evaluated and compared the sealing efficacy of felt versus pericardium in a human cadaver model. Methods: ATAAD was simulated in 20 fresh human cadavers. Repairs were performed using the sandwich technique with either felt (n = 10) or pericardium (n = 10), followed by end-to-end prosthetic graft anastomosis. Procedure time was recorded. Following the repair, the aortas were perfused at 160/90 mmHg using a glycerol-water solution to assess fluid leakage (mL), DANE and PFL. Results: Median leakage was significantly lower in the pericardium group (67.5 mL [IQR 40–198.8]) compared to the felt group (315 mL [IQR 285–445], p = 0.002). Procedure times were comparable between groups. DANE occurred in 20% (pericardium) and 30% (felt) of cases, while PFL was observed in 30% of cases in both groups; differences were not statistically significant. Conclusions: The superior sealing properties of pericardium in this study suggest a promising approach for reducing leakage in ATAAD repair. While rates of DANE and PFL were comparable, the advantage of pericardium was confined to leakage reduction. These findings highlight the need for further research to determine whether this experimental benefit translates into improved clinical outcomes.
17 November 2021 in Multimedia Manual of Cardio-Thoracic Surgery
The use of the novel bidirectional femoral cannula is described in this video tutorial. We demonstrate the percutaneous cannulation and decannulation of the femoral artery for cardiopulmonary bypass in a patient undergoing minimally invasive mitral valve surgery. The procedure itself is presented step by step for each important phase. Finally, we report the postoperative course following the successful use of a peripheral bidirectional cannula.