David Stránský

Dr. David Stránský


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2009 in Water Science & Technology
Verified
Journal Article
Closed access
VBV. Bareš
V. Bareš
DSDavid Stránský
David Stránský
PSP. Sýkora
P. Sýkora
The paper deals with a method for quantification of infiltrating groundwater based on the variation of diurnal pollutant load and continuous water quality and quantity monitoring. Although the method gives us the potential to separate particular components of wastewater hygrograph, several aspects of the method should be discussed. Therefore, the paper investigates the cost-effectiveness, the relevance of pollutant load from surface waters (groundwater) and the influence of measurement time step. These aspects were studied in an experimental catchment of Prague sewer system, Czech Republic, within a three-month period. The results indicate high contribution of parasitic waters on night minimal discharge. Taking into account the uncertainty of the results and time-consuming maintenance of the sensor, the principal advantages of the method are evaluated. The study introduces a promising potential of the discussed measuring concept for quantification of groundwater infiltrating into the sewer system. It is shown that the conventional approach is sufficient and cost-effective even in those catchments, where significant contribution of foul sewage in night minima would have been assumed.

22 June 2022 in Water
Verified
Journal Article
Open access
PDF file
Bartosz SzelągBartosz Szeląg
Bartosz Szeląg
Grzegorz ŁagódGrzegorz Łagód
Grzegorz Łagód
Annan Musz-PomorskaAnnan Musz-Pomorska
Annan Musz-Pomorska
Marcin WidomskiMarcin Widomski
Marcin Widomski
DSDavid Stránský
David Stránský
RBRoman Babko
Roman Babko
Modelling of stormwater networks and the related object (combined sewer overflows, diversion chambers, retention tanks) is a complex task requiring colleting of data with appropriate time and spatial resolution as well as application of adequate models. Often there is a need to find balance between the costs of conducting measurement (period, resolution) and the uncertainty of the model results. This paper presents an overview of simulation tools for sewerage networks modelling, related objects, as well as low-impact development (LID) systems in relation to the hydrodynamic and statistical models. Consecutive stages of data collection, sources of data uncertainty, limitations resulting from the adopted measurement methodology, as well as their influence on the simulation results and possible decision-making using the developed hydrodynamic or statistical model, are discussed. Attention is drawn to the optimization methods enabling reduction in the uncertainty of statistical models. The methods enabling the analysis of model uncertainty, as well as evaluation of its influence on the calculation results pertaining to stormwater hydrographs, retention tank capacity and combined sewers overflows, are also discussed. This is a very important aspect in terms of optimizing construction works in the sewerage network and designing their appropriate dimensions to achieve the assumed hydraulic effects.

5 April 2018 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
DSDavid Stránský
David Stránský
MFMartin Fencl
Martin Fencl
VBVojtech Bares
Vojtech Bares
Rainfall spatio-temporal distribution is of great concern for rainfall-runoff modellers. Standard rainfall observations are, however, often scarce and/or expensive to obtain. Thus, rainfall observations from non-traditional sensors such as commercial microwave links (CMLs) represent a promising alternative. In this paper, rainfall observations from a municipal rain gauge (RG) monitoring network were complemented by CMLs and used as an input to a standard urban drainage model operated by the water utility of the Tabor agglomeration (CZ). Two rainfall datasets were used for runoff predictions: (i) the municipal RG network, i.e. the observation layout used by the water utility, and (ii) CMLs adjusted by the municipal RGs. The performance was evaluated in terms of runoff volumes and hydrograph shapes. The use of CMLs did not lead to distinctively better predictions in terms of runoff volumes; however, CMLs outperformed RGs used alone when reproducing a hydrograph's dynamics (peak discharges, Nash–Sutcliffe coefficient and hydrograph's rising limb timing). This finding is promising for number of urban drainage tasks working with dynamics of the flow. Moreover, CML data can be obtained from a telecommunication operator's data cloud at virtually no cost. That makes their use attractive for cities unable to improve their monitoring infrastructure for economic or organizational reasons.

8 November 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
LNLukáš Novák
Lukáš Novák
IKIvana Kabelkova
Ivana Kabelkova
DHDavid Hora
David Hora
DSDavid Stránský
David Stránský
Trees in dense urban environments are often planted in bioretention cells with an underlying trench (BC-T) providing both stormwater pretreatment and storage. The BC-T design is based on a water balance; however, some input data (tree water uptake and water-holding capacities of soil filter and trench substrate) are difficult to obtain. The goals of this paper were (i) to study the sensitivity of such data in the BC-T design (i.e., their effect on the size of the drained area which may be connected to the tree pit), and (ii) to recommend a possible simplification of the water balance for engineering practice. Global sensitivity analysis was performed for the setup of a BC-T used in Prague, Czech Republic, assuming three different trench exfiltration rates. The most sensitive variable affecting the size of the drained area is the available water-holding capacity in the trench. The simplification of the water balance is highly dependent on exfiltration conditions. At high exfiltration rates (18 mm·h−1 and more) or for a trench with an underdrain, the water-holding capacity in the soil filter and the tree water uptake can be omitted; whereas, at low trench exfiltration rates (1.8 mm·h−1, without an underdrain), both the water-holding capacity of the trench substrate and the potential tree water uptake have a significant influence and cannot be omitted.

9 April 2021 in Water
Verified
Journal Article
Open access
PDF file
Bartosz SzelągBartosz Szeląg
Bartosz Szeląg
AKAdam Kiczko
Adam Kiczko
Annan Musz-PomorskaAnnan Musz-Pomorska
Annan Musz-Pomorska
Marcin WidomskiMarcin Widomski
Marcin Widomski
JZJacek Zaburko
Jacek Zaburko
MSMarek Sokáč
Marek Sokáč
Pipe tanks represent important runoff retention elements of urban stormwater systems. They enable us to reduce and retain runoff as well as to mitigate peak flows in the network. Pipe tanks are often taken into account while designing the spatial plan of urban catchment areas. Hence, there is a need to develop a relatively quick and accurate method for pipe tank dimensioning. A graphical–analytical method of designing a pipe tank is presented in the paper. In the assumed methodology, the possibility of employing machine learning for obtaining a more precise error prediction of the proposed pipe tank design method (compared with the tank volume simulations using the storm water management model (SWMM)) are considered. Thus far, this aspect has not been discussed in the literature. In the adopted calculation methodology, sensitivity analysis constitutes an important element, enabling us to assess the influence of the input data assumed for tank design on the dimensions of the outflow devices and the length of the retention chamber.

1 March 2016 in Ecological Chemistry and Engineering S
Verified
Journal Article
Open access
PDF file
DSDavid Stránský
David Stránský
IKIvana Kabelkova
Ivana Kabelkova
VBVojtech Bares
Vojtech Bares
GSGabriela Stastna
Gabriela Stastna
Zbigniew SuchorabZbigniew Suchorab
Zbigniew Suchorab