Most of ultrasound medical imaging systems currently on the market implement standard Delay and Sum (DAS) beamforming to form B-mode images. However, image resolution and contrast achievable with DAS are limited by the aperture size and by the operating frequency. For this reason, different beamformers have been presented in the literature that are mainly based on adaptive algorithms, which allow achieving higher performance at the cost of an increased computational complexity. In this paper, we propose the use of an alternative nonlinear beamforming algorithm for medical ultrasound imaging, which is called Delay Multiply and Sum (DMAS) and that was originally conceived for a RADAR microwave system for breast cancer detection. We modify the DMAS beamformer and test its performance on both simulated and experimentally collected linear-scan data, by comparing the Point Spread Functions, beampatterns, synthetic phantom and in vivo carotid artery images obtained with standard DAS and with the proposed algorithm. Results show that the DMAS beamformer outperforms DAS in both simulated and experimental trials and that the main improvement brought about by this new method is a significantly higher contrast resolution (i.e., narrower main lobe and lower side lobes), which turns out into an increased dynamic range and better quality of B-mode images.
23 April 2010 in Journal of NeuroEngineering and Rehabilitation
Functionality, controllability and cosmetics are the key issues to be addressed in order to accomplish a successful functional substitution of the human hand by means of a prosthesis. Not only the prosthesis should duplicate the human hand in shape, functionality, sensorization, perception and sense of body-belonging, but it should also be controlled as the natural one, in the most intuitive and undemanding way. At present, prosthetic hands are controlled by means of non-invasive interfaces based on electromyography (EMG). Driving a multi degrees of freedom (DoF) hand for achieving hand dexterity implies to selectively modulate many different EMG signals in order to make each joint move independently, and this could require significant cognitive effort to the user.
1 January 2012 in Journal of NeuroEngineering and Rehabilitation
In spite of the advances made in the design of dexterous anthropomorphic hand prostheses, these sophisticated devices still lack adequate control interfaces which could allow amputees to operate them in an intuitive and close-to-natural way. In this study, an anthropomorphic five-fingered robotic hand, actuated by six motors, was used as a prosthetic hand emulator to assess the feasibility of a control approach based on Principal Components Analysis (PCA), specifically conceived to address this problem. Since it was demonstrated elsewhere that the first two principal components (PCs) can describe the whole hand configuration space sufficiently well, the controller here employed reverted the PCA algorithm and allowed to drive a multi-DoF hand by combining a two-differential channels EMG input with these two PCs. Hence, the novelty of this approach stood in the PCA application for solving the challenging problem of best mapping the EMG inputs into the degrees of freedom (DoFs) of the prosthesis.
16 March 2017 in IEEE Transactions on Microwave Theory and Techniques
Medical imaging currently relies on several techniques, including X-rays, magnetic resonance, and echography. However, these techniques exhibit drawbacks, and alternative approaches are required. Microwave imaging has been proposed as a possible solution, especially for breast cancer imaging. However, most of these systems work with a central frequency of a few gigahertz, and this leads to a suboptimum resolution, which can jeopardize the image quality. Millimeter waves can provide superior resolutions, at the cost of a lower penetration depth within the breast tissue. In addition, a significant fraction of the power generated by a mm-wave imaging system would be reflected back from the skin. For these reasons, and also considering that mm-wave transmitters and receivers have been historically outperformed by microwave counterparts in terms of available power and sensitivity, mm-wave imaging has not been considered a possible solution. This paper contributes to demonstrate a paradigm shift toward the possible use of mm-waves for breast cancer imaging of targets a few centimeter below the skin, a useful penetration depth for several cases. All key points are addressed using analytical, full-wave, and multiphysics simulations, including the system architecture (linear and conformal), the safety aspects (power density, specific absorption rate, and temperature increase), and the use of realistic breast models derived from ex vivo measurements.
4 October 2016 in IEEE Transactions on Medical Imaging
Multi-Line Transmission (MLT) was recently demonstrated as a valuable tool to increase the frame rate of ultrasound images. In this approach, the multiple beams that are simultaneously transmitted may determine cross-talk artifacts that are typically reduced, although not eliminated, by the use of Tukey apodization on both transmission and reception apertures, which unfortunately worsens the image lateral resolution. In this paper we investigate the combination, and related performance, of Filtered-Delay Multiply And Sum (F-DMAS) beamforming with MLT for high frame-rate ultrasound imaging. F-DMAS is a non-linear beamformer based on the computation of the receive aperture spatial autocorrelation, which was recently proposed for use in ultrasound B-mode imaging by some of the authors. The main advantages of such beamformer are the improved contrast resolution, obtained by lowering the beam side lobes and narrowing the main lobe, and the increased noise rejection. This study shows that in MLT images, compared to standard Delay And Sum (DAS) beamforming including Tukey apodization, F-DMAS beamforming yields better suppression of cross-talk and improved lateral resolution. The method's effectiveness is demonstrated by simulations and phantom experiments. Preliminary in vivo cardiac images also show that the frame rate can be improved up to 8-fold by combining F-DMAS and MLT without affecting the image quality.
Millimeter (mm)-wave imaging has been recently proposed as a new technique for breast cancer detection, based on the significant dielectric contrast between healthy and tumor tissues. Here we propose a procedure to fabricate, electromagnetically characterize and preserve realistic breast tissue-mimicking phantoms for testing mm-wave imaging prototypes. Low-cost, non-toxic and easy-to-produce mixtures made of sunflower oil, water and gelatin were prepared and their dielectric properties were for the first time measured in the (0.5–50) GHz frequency range using a coaxial probe kit. Different oil and gelatin percentages were tested. An alternative recipe based on a waste-oil hardener was also proposed. Finally, water and sunflower oil were investigated as preservation media. The mixtures electromagnetic properties were in good agreement with those of human breast ex vivo samples. By changing the ingredient concentrations or using different solidifying agents it was possible to mimic different tissue types. Besides, we show that sunflower oil represents an effective preservation medium for the developed materials. The first breast phantom mimicking a tumor mass into healthy tissues up to 50 GHz was also successfully fabricated. Results demonstrated the potential of the designed recipes to mimic breast tissues with different biological characteristics, preserving dielectric properties over time. Thus, this study represents a fundamental step towards the development of heterogeneous breast phantoms able to mimic the electromagnetic behavior of healthy and tumor tissues for mm-wave imaging applications.