Supernumerary robotic limbs are mainly designed to augment the physical capabilities of able-bodied individuals, in a wide range of contexts from body support to surgery. When they are worn as wearable devices, they naturally provide inherent feedback due to the mechanical coupling with the human body. The user can, thus, perceive the interaction with the environment by relying on a combination of visual and inherent feedback. However, these can be inefficient in accomplishing complex tasks, particularly in the case of visual occlusion or variation in the environment stiffness. Here, we investigated whether, in a force-regulation task using a wearable supernumerary robotic arm (SRA), additional vibrotactile feedback can increase the control performance of participants compared to the inherent feedback. Additionally, to make the scenario more realistic, we introduced variations in the SRA’s kinematic posture and in the environment stiffness. Notably, our findings revealed a statistically significant improvement in user performance over all the evaluated metrics while receiving additional vibrotactile feedback. Compared to inherent feedback alone, the additional vibrotactile feedback allowed participants to exert the required force faster (p < 0.01), to maintain it for longer (p < 0.001), and with lower errors (p < 0.001). No discernible effects related to the SRA’s posture or environment stiffness were observed. These results proved the benefits of providing the user with additional vibrotactile feedback to convey the SRA’s force during interaction tasks.
In neonates with pulmonary hypertension (PH) supported on veno-venous extracorporeal membrane oxygenation (VV-ECMO), keeping the ductus arteriosus (DA) open ensures a high cardiac output of well-oxygenated blood through the right to left (R-L) ductal shunt. After PH resolution, timely closure of the patent DA (PDA) prevents pulmonary overcirculation, systemic hypoperfusion, and unsuccessful ECMO weaning. We retrospectively evaluated its impact on the echocardiographic and hemodynamic features of 18 newborns undergoing VV-ECMO because of acute hypoxic respiratory failure in PH. At ECMO start, PDA was left or maintained open for all patients with echocardiographic signs of PH. After ECMO initiation, PDA shunt reverted into left to right (L-R). Twenty-four hours before DA closure, the echocardiographic assessment suggested a drop in pulmonary vascular resistances (PVRs). At 24 and 48 hours after DA closure, cardiac ultrasound confirmed continued improvement of PH. Ductus arteriosus closure is associated with a significant drop in arterial lactates ( p = 0.014) and increase in diastolic blood pressure ( p = 0.037). All patients, except for the two who died on ECMO, were successfully weaned from extracorporeal life support. Overall survival was 61.1%. These preliminary data suggest the feasibility and safety of DA patency manipulation in neonates undergoing VV-ECMO for PH, supporting a VV configuration in this patient population.
1 February 2026 in IEEE Transactions on Medical Robotics and Bionics