5 September 2025 in Research Square
Verified
Preprint
Open access
PDF file
FMFabio Morelli
Fabio Morelli
AAAlessandro Albanesi
Alessandro Albanesi
AIAlice Ivanaj
Alice Ivanaj
SBSilvia Buratti
Silvia Buratti
FPFrancesca Parrotta
Francesca Parrotta
ARAlberto Redaelli
Alberto Redaelli
This study aims at developing and experimentally validate a three-dimensional numerical model designed to predict acoustic propagation and thermal effects during High-Intensity Focused Ultrasound (HIFU) therapy, in order to support patient-specific treatment planning. A 3D time-domain simulation was implemented using the k-Wave toolbox, capturing both acoustic wave propagation and thermal effects. Validation was performed using five tissue-mimicking phantoms with distinct acoustic and thermal properties, each tested under three different HIFU exposure conditions. Lesion dimensions were assessed longitudinally and transversely in both simulations and experiments, and spatial concordance was quantified by evaluating the overlap between simulated and experimental lesions. Simulated longitudinal lesion extents fell within the interquartile range of experimental data in five out of nine phantom-condition combinations with a maximum absolute error of 2.70 mm while transverse dimensions in three out of nine with maximum absolute error equal to 4.16 mm. Spatial overlap between simulated and experimental lesions reached a maximum of 92%. Simulations on phantoms required approximately 16 minutes, while patient-specific cases completed in about 32 minutes, accurately capturing heterogeneous tissue characteristics and bone interfaces. In scenarios involving rib intersection, a 40% reduction in focal pressure was observed, leading to significant smaller lesions. The validated 3D simulation, integrated into a planning platform, reliably predicts HIFU ablation zones and focal shifts, showing strong agreement with experimental data and delivering results within clinically feasible times.

15 December 2025 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Open access
FPFrancesca Parrotta
Francesca Parrotta
GFGiovanni Faoro
Giovanni Faoro
STSelene Tognarelli
Selene Tognarelli
AGAlberto Giannoni
Alberto Giannoni
Arianna MenciassiArianna Menciassi
Arianna Menciassi
Minimally Invasive Surgery (MIS) for cardiac procedures was adopted in the late 90s as a valid alternative to open-heart surgeries, allowing for a minor operative trauma and a faster post-operative recovery. In the context of MIS, the presence of accurate imaging techniques is of paramount importance, as surgeons operate without a direct view of the surgical site. Nowadays, fluoroscopic and ultrasound (US) images, using a Trans-Esophageal probe, are simultaneously employed. The development of real-time three-dimensional Trans-Esophageal Echocardiography has enabled the execution of various trans-catheter procedures. However, recent studies have highlighted the occurrence of esophageal lesions following TEE-guided cardiac interventions. Specifically, blind probe insertion and repeated adjustment for optimal instrument guidance, along with prolonged use-induced heating, appear to be the primary causes of complications. The major reason for using a dual imaging technique is that commercial probes automatically switch off once a temperature threshold of approximately 42.5∘C is reached; for safety reasons related to potential thermal damage to the internal walls of the esophagus. Based on numerical simulations and experimental results, a miniaturized cooling device for TEE probes is proposed, thus reinforcing the reliability of US images in the intraoperative scenario, as they are completely harmless to both patients and doctors. The proposed system consists of a silicone cap incorporating an internal cooling circuit. It does not interfere with the clinical workflow, effectively maintains the probe within a safe temperature range for the entire duration of a surgical procedure, and does not compromise intraoperative image quality.

1 February 2026 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Open access
SBSilvia Buratti
Silvia Buratti
DMDaniele Moglia
Daniele Moglia
FPFrancesca Parrotta
Francesca Parrotta
STSelene Tognarelli
Selene Tognarelli
Andrea CafarelliAndrea Cafarelli
Andrea Cafarelli
Arianna MenciassiArianna Menciassi
Arianna Menciassi

12 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FPFrancesca Parrotta
Francesca Parrotta
STSelene Tognarelli
Selene Tognarelli
Arianna MenciassiArianna Menciassi
Arianna Menciassi
High-intensity focused ultrasound (HIFU) thermal therapy exploits concentrated acoustic energy to ablate pathological tissues with millimetric precision deep in the body. Accurate prediction of thermal effects is essential for tuning the treatment shooting parameters—such as source pressure amplitude and sonication time—as well as for maximizing efficacy and preserving surrounding healthy tissue. This study presents a computational model developed in COMSOL Multiphysics to simulate the physics of HIFU thermal phenomena, accounting for acoustic propagation and heat diffusion in biological tissues. The model was validated through experimental tests on ex vivo chicken breast tissue within a robotic ultrasound-guided HIFU (USgHIFU) platform, with lesion dimensions serving as the primary metric for validation. Building upon the validated simulation, we define a polynomial-based model that analytically predicts lesion dimensions based on the input shooting parameters. This approach significantly reduces the COMSOL computational cost and execution time, making it well-suited for integration into a real-time treatment planning workflow for clinical use. A desktop application implementing the inverse formulation of the polynomial model was developed, allowing shooting parameters to be computed from target lesion dimensions through a simple and intuitive interface. By enabling a rapid estimation of lesion size, this solution supports a more standardized strategy for non-invasive oncological therapies.