Md. Abu Noaman

Mr. Md. Abu Noaman


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Heliyon
Verified
Journal Article
Open access
MNMd. Abu Noaman
Md. Abu Noaman
MKMd. Rezul Karim
Md. Rezul Karim
MIMd. Nazrul Islam
Md. Nazrul Islam
The aim of this study was to investigate the pozzolanic effect (PE) and filler effect (FE) of rice husk ash (RHA) on the mechanical properties and microstructure of brick aggregate concrete (BAC). For this, concrete cylinders (100 mm × 200 mm) were prepared with 0-25% RHA with water-to-binder ratios of 0.50 at a constant mix-ratio of 1:1.5:3 and cured in water. Test results revealed that the mean particle size of RHA decreases with increasing grinding time. The compressive strength ( f c ' ) of BAC due to filler effect are 58.56-94.62% less compared to the pozzolanic effect of RHA for the 10%-25% replacement of cement. Meanwhile, the 15% RHA showed the maximum f c ' of BAC due to pozzolanic effect of RHA. The tensile strength ( f s p ) and flexural strength ( f r ) of BAC due to pozzolanic effect are 60%-150% and 25%-150% higher than that of filler effect of RHA for the 10%-25% replacement of cement respectively. The modulus of elasticity ( E c ) and Poisson's ratio ( ν ) of BAC due to pozzolanic effect are 2%-29% and 27%-43% greater than that of filler effect of RHA for the 10%-25% replacement of cement respectively. BAC with 10-20% RHA shows a dense and homogeneous microstructure. Therefore, inclusion of RHA as a partial replacement of cement possesses a significant pozzolanic effect than the filler effect on the mechanical properties and microstructure of BAC.

1 June 2018 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
MNMd. Abu Noaman
Md. Abu Noaman
MIMd. Nazrul Islam
Md. Nazrul Islam
MD RAKIBUL ISLAMMD RAKIBUL ISLAM
MD RAKIBUL ISLAM
MKMd. Rezul Karim
Md. Rezul Karim
The objective of this research was to determine the mechanical properties, including among others compressive strength (fc′) , tensile strength (fsp) , flexural strength (fr) , modulus of elasticity (Ec) , and Poisson’s ratio (ν) of a brick aggregate concrete (BAC) containing rice husk ash (RHA) as a partial replacement of cement. Concrete cylinders with 100-mm diameter and 200-mm height were cast using 0–25% RHA as a partial replacement of cement with water-to-binder ratios of 0.45, 0.50, and 0.55, with a mix ratio of 1:1.5:3, and cured in water at room temperature. The experimental results indicated that fc′ and fsp increased gradually with the increasing RHA up to 15%. However, the maximum values of these were observed with 10% RHA. By contrast, fr of BAC containing up to 25% RHA was found lower than that of control concrete. Ec and ν of BAC with RHA were higher than those of control concrete. It was observed that mechanical properties of BAC were influenced significantly due to the inclusion of 15% RHA as a partial replacement of cement with a water-to-binder ratio of 0.50.

30 March 2024 in Heliyon
Verified
Journal Article
Open access
MIMd. Nazrul Islam
Md. Nazrul Islam
MNMd. Abu Noaman
Md. Abu Noaman
KIKhandaker Saiful Islam
Khandaker Saiful Islam
MHMohammad Abu Hanif
Mohammad Abu Hanif
In response to environmental concerns, researchers explore fly ash as a cement replacement material, and crushed bricks as a cost-effective and load-reducing aggregate, particularly where stone chips are scarce. Therefore, this study investigates the mechanical properties and microstructure of brick aggregate concrete (BAC) with raw fly ash (FA) as a partial replacement of cement. The research involved casting raw FA based BAC (FBAC) cylinders (100 mm diameter and 200 mm height) and prism (100 × 100 × 500 mm) with varying levels of FA (0–25%) using a constant mix proportion by volume of 1:1.5:3 (cement : fine aggregate : coarse aggregate) with a water to binder (w/b) ratio of 0.50 and three curing ages (7, 28, and 90 days). Tests for mechanical properties, including compressive strength, split tensile strength, flexural strength, modulus of elasticity, and Poisson's ratio were conducted to assess the behavior of FBAC, and microstructure were then investigated at 28 days. The results indicated that increasing the FA content up to 15% led to gradual improvement in compressive strength and tensile strength values. At 28 days, the highest values of compressive strength and split tensile strength were observed at 10% FA, with 7.9% and 14.2% increase, respectively, compared to the control concrete. However, the flexural strength of FBAC decreased gradually with cement replacement. On the other hand, modulus of elasticity and Poisson's ratio increased gradually up to 20% and 25% cement replacement, respectively. Up to 15% FA enhanced a more uniform and compact microstructure than that of control concrete. Several equations have been developed to express relationship between compressive strength and other mechanical properties of FBAC. Hence, up to 15% raw FA as a partial replacement of cement improved the mechanical properties and microstructure of BAC.

31 May 2022 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
MNMd. Abu Noaman
Md. Abu Noaman
RKRezaul Karim
Rezaul Karim
NINazrul Islam
Nazrul Islam
SMSuman Mia
Suman Mia
This study assessed the strength and durability parameters of brick aggregate concrete (BAC) incorporating rice husk ash (RHA) as a partial replacement of cement. For this, concrete cylinders (100mm×200mm) were made with 0 (control) to 25 RHA as a partial replacement of ordinary Portland cement (OPC) at a mix proportion of 1:1.5:3 and a water-to-binder (w/b) ratio of 0.50. Specimens were immersed separately in normal water, 3 sodium chloride (NaCl), 5 sodium sulfate (Na2SO4), 5 magnesium sulfate (MgSO4), 1 hydrochloric acid (HCl), and 1 sulfuric acid (H2SO4) solutions for several immersion periods. The slump test results indicated that the workability of BAC containing RHA (RBAC) decreased about 29.6975.02 compared to control (0 RHA). After 90 days, the BAC containing RHA (up to 15 replacement) was found approximately 2.286.64 greater compressive strength than that of control concrete. In addition, water absorption and porosity of RBAC were around 17.5940.73 and 12.1235.68 lower than that of control concrete, respectively. Similarly, RBAC (up to 25 replacement) exhibited roughly 35.6254.79 higher resistance against chloride attack and 0.394.56 better resistance against Na2SO4 attack (up to 15 replacement), however, it exhibited inferior resistance against MgSO4 attack compared to control. Meanwhile, BAC with 10 RHA showed about 5.35 and 1.00 superior performance than that of control concrete against HCl and H2SO4 attack, respectively. The relationships between the strength and durability parameters of RBAC also suggested that RHA contributes to improving the strength and durability parameters of BAC.

18 November 2025
Verified
Book Chapter
Open access
PDF file
NANur Alam
Nur Alam
MNMd. Abu Noaman
Md. Abu Noaman
Md. Kamrul Hasan KawsarMd. Kamrul Hasan Kawsar
Md. Kamrul Hasan Kawsar
ASAbu Saleh
Abu Saleh
RKRezaul Karim
Rezaul Karim
The present study explores the properties of brick aggregate concrete (BAC) incorporating plastic waste (PW) as a partial replacement of fine aggregates. A total of 108 cylindrical BAC specimens (100 mm × 200 mm) were cast with PW replacing fine aggregates at 0%–10%, using a 1:2:4 volumetric mix and water-cement ratios (w/c) of 0.45 and 0.50. After the slump test, the hardened density, compressive strength, split tensile strength, modulus of elasticity, and Poisson’s ratio were performed at several curing ages. Early-age water absorption and porosity were assessed after 7 days of curing. The test results indicated that the workability of BAC declined with increasing PW content at both w/c ratios, with better workability at 0.50, prompting further studies at this ratio. The hardened density of BAC with PW (BPW) reduced by 0.2–7.4% compared to the control concrete (0% PW). The compressive strength of BPW declined by 13.7–50.0%, 16.8–56.9%, and 16.7–52.0% after 7, 28, and 56 days of curing, respectively. Split tensile strength decreased by 16.0–40.0%, 17.2–41.4%, and 16.7–40.0% at 7, 28, and 56 days, respectively. The modulus of elasticity and Poisson’s ratio decreased by 3.4–10.7% and 8.3–29.2% at 28 days, respectively. Moreover, water absorption and porosity increased by 14.8–67.2% and 18.3–83.5% compared to control concrete. The findings underscore the potential of integrating PW into BAC. Therefore, future research should focus on identifying PW characteristics to ensure BAC performance.