We assessed the accuracy of a prototype radiation detector with a built in CMOS amplifier for use in dosimetry for high dose rate brachytherapy. The detectors were fabricated on two substrates of epitaxial high resistivity silicon. The radiation detection performance of prototypes has been tested by ion beam induced charge (IBIC) microscopy using a 5.5 MeV alpha particle microbeam. We also carried out the HDR Ir-192 radiation source tracking at different depths and angular dose dependence in a water equivalent phantom. The detectors show sensitivities spanning from (5.8 ± 0.021) × 10−8 to (3.6 ± 0.14) × 10−8 nC Gy−1 mCi−1 mm−2. The depth variation of the dose is within 5% with that calculated by TG-43. Higher discrepancies are recorded for 2 mm and 7 mm depths due to the scattering of secondary particles and the perturbation of the radiation field induced in the ceramic/golden package. Dwell positions and dwell time are reconstructed within ±1 mm and 20 ms, respectively. The prototype detectors provide an unprecedented sensitivity thanks to its monolithic amplification stage. Future investigation of this technology will include the optimisation of the packaging technique.
Calabazas Creek Research, Inc. is developing several high efficiency RF sources ranging in frequency from 300 MHz to 2.45 GHz and higher at power levels ranging from a few kW to more than 200 kW CW. Applications range from driving high energy accelerators and colliders to high data rate communications. All devices are designed to provide efficiencies exceeding 80%. These devices include (1) a phase and amplitude controlled magnetron producing 100 kW at 1.3 GHz using phase modulation of a locking RF signal, (2) a multiple beam triode-based RF sources to produce 200 kW from 300-500 MHz, (3) a high efficiency klystron to produce 100 kW CW at 1.3 GHz, (4) a multiple beam inductive output tube to produce 200 kW at 700 MHz, and (5) a magnetron with frequency and phase control provided by varactor diodes to produce 5 kW CW at 2.45 GHz capable of 2Mb/second data transmission rate. The amplitude-controlled magnetron has been completed and tested, and the high efficiency klystron and triode-based source are being assembled with testing schedule for spring 2022. Drawings are in progress for the multiple beam IOT, and the design of the varactor-controlled magnetron is in progress. These devices will be described and available test results presented.
Calabazas Creek Research, Inc. is developing a high efficiency, 1.3 GHz, 100 kW CW klystron for driving accelerators. A design with an efficiency of 79% has been realized and a device is being assembled.