Deog Jae Hur

Prof. Dr. Deog Jae Hur

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DHDeog Jae Hur
Deog Jae Hur
SKSangyoup Kwon
Sangyoup Kwon
The design strength of a greenhouse structure is generally determined by analyzing strength after applying wind load using the wind pressure coefficient according to a design guide. Until now, the stability analysis for wind load has been performed through static structural analysis. However, a greenhouse is subjected to dynamic wind loads of various amplitudes, and it is reasonable to judge stability through fatigue analysis. For fatigue analysis, a stress-normalized model was constructed based on the square of wind speed, and the value obtained by squaring wind speed was used as dynamic load time data. Life cycle was calculated under stress generated by self-weight by compensating fatigue estimation stress. Furthermore, the effect of self-weight was examined and errors of up to 21% were obtained depending on the configuration of the stress-normalized model. When self-weight and wind speed were applied simultaneously, the effect of self-weight reduced when the stress-normalized model was used at high wind speed. Therefore, it is appropriate that the fatigue analysis is based on the fatigue stress model normalized by the square of wind speed, fatigue estimation stress is corrected to the static stress due to self-weight, and the square of wind speed is used as the dynamic load.

2 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
MKMin-Jun Kim
Min-Jun Kim
SBSang-Hwan Bak
Sang-Hwan Bak
WJWoo-Chul Jung
Woo-Chul Jung
DHDeog Jae Hur
Deog Jae Hur
DKDong-Shin Ko
Dong-Shin Ko
MKMansik Kong
Mansik Kong
In order to improve energy efficiency by increasing heat dissipation performance of bus-bar which distributes the current in high-power switchboard, the heat dissipation effects of the shape modification and surface treatment of Cu bus-bar were studied. The surface temperatures of the conventional plate-type bus-bar, and the improved tunnel-type bus-bar were compared by using electromagnetic and thermal analyses. The optimum thickness of tunnel-type bus-bar and the spacing and array among three bus-bars were calculated; and the surface temperature of tunnel-type bus-bar showed 7.9 °C lower than that of plate-type bus-bar in a 3-phase array condition. In addition, the surface and internal temperatures of the uncoated, CNT (Carbon nanotube)-coated, and BN (Boron nitride)-coated Cu bus-bars were measured with thermal imaging camera and the experiment using a hot plate. It was confirmed that the difference in the internal temperature between uncoated and BN-coated Cu was 19.4 °C. The application of the bus-bar improved from this study might contribute to the increase in power energy efficiency.

23 April 2017 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
DKDong Shin Ko
Dong Shin Ko
DHDeog Jae Hur
Deog Jae Hur
TPTae Won Park
Tae Won Park
JLJai Hyuk Lee
Jai Hyuk Lee

19 February 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DHDeog Jae Hur
Deog Jae Hur
SHSung Chul Hong
Sung Chul Hong
This paper proposes a new vibration isolation mounting system, with spherical balls and vertical spring dampers, that provides seismic protection from horizontal and vertical ground excitation. To characterize the system, nonlinear governing equations are derived by considering the kinematics and interaction forces of the structures, and the dynamic characteristics of the design parameters are investigated by numerical analysis. The condition of contact stability for sustaining continuous friction of the isolation device is discussed, along with the design parameters. The vibration transfer characteristics are analyzed for the displacement transfer ratio obtained for the design parameters satisfying the sustainable contact condition, when the base is harmonically excited. The results confirm that the relative motion occurrence satisfies the conditional expression, and a jump in which the transfer ratio suddenly increases at a specific frequency is identified. Finally, design variables that are suitable for the horizontal and vertical acceleration of the El Centro earthquake are set, and a simulation confirms the vibration reduction effect in both the horizontal and vertical motions.

8 June 2017 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
JLJai Hyuk Lee
Jai Hyuk Lee
DKDong Shin Ko
Dong Shin Ko
SKSang Youp Kwon
Sang Youp Kwon
JKJae Yong Kim
Jae Yong Kim
DHDeog Jae Hur
Deog Jae Hur
This study derives an optimal design of electromagnetic force, verifies the analysis of the optimum, and runs the vibration test to consider various properties of the optimal design in order to optimize the performance of the bone conduction speakers used in Smart Glasses, one of smart wearable devices. For performance factors that affect the electromagnetism of actuator in a bone conduction speaker which holds a magnetic structure, the diaphragm height, yoke pole height, magnet height, magnet and plate width, and coil turn number were selected. To analyze the properties of the performance factors, responsive factors needed to be classified first using fractional factorial design and full factorial design was used for influence analysis. The F-test was done as the means to conduct the valence test to show the independence and reciprocal action for selected performance factors, and it concluded that three independence factors were valid. Based on the valid performance factors, a regression equation to predict its performance was deducted and using the equation, an optimal design to maximize the electromagnetic force performance per component. To verify the characteristics of the optimal model, the finite element method (FEM) was used for analysis. Through electromagnetic analysis, magnetic flux density was obtained, and the particular information along with current and coil length contributed to deriving 0.052 N of electromagnetic force. After completing the frequency response analysis based on the electromagnetic force, it resulted in the 0.0772 mm of displacement at 590.12 Hz of resonant frequency. A sample model was fabricated, followed by vibration testing, after optimal design and analytical verification. Hence, it is verified that the optimal design method and the credibility of the analysis of this study is deemed very high. Furthermore, utilizing this mechanism would inspect the effect of the design parameter performance and increase the credibility and efficiency of a design.

30 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JNJung-hun Noh
Jung-hun Noh
SSSeong-Il Song
Seong-Il Song
DHDeog Jae Hur
Deog Jae Hur
To satisfy increasing demands for ecofriendly vehicles, researchers are now studying electric vehicle (EV)-related technologies. In particular, integrated bidirectional onboard battery charger (OBC)/low-voltage DC–DC converter (LDC) modules are being researched to improve the efficiency of onboard chargers for EV charging applications. In this study, a numerical analysis method is proposed that considers the power loss and heat flow characteristics in the design of a 7.2 kW integrated bidirectional OBC/LDC module. The developed module supports four operating modes depending on the service situation: OBC and LDC single operation, OBC/LDC simultaneous operation, and LDC operation. The mode is selected based on the power system flow. The characteristics of the circuit were analyzed in each of the four modes to compute the heat loss from the major heating elements. The results of a numerical analysis of the internal cooling characteristics showed that the internal temperature was higher in the OBC single operating mode than in the OBC and LDC simultaneous operating mode in which the power loss was the highest. The results emphasize the importance of ensuring that cooling designs consider the characteristics of various modes as well as the worst-case power loss.