Mansik Kong

Mansik Kong


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
MKMin-Jun Kim
Min-Jun Kim
SBSang-Hwan Bak
Sang-Hwan Bak
WJWoo-Chul Jung
Woo-Chul Jung
DHDeog Jae Hur
Deog Jae Hur
DKDong-Shin Ko
Dong-Shin Ko
MKMansik Kong
Mansik Kong
In order to improve energy efficiency by increasing heat dissipation performance of bus-bar which distributes the current in high-power switchboard, the heat dissipation effects of the shape modification and surface treatment of Cu bus-bar were studied. The surface temperatures of the conventional plate-type bus-bar, and the improved tunnel-type bus-bar were compared by using electromagnetic and thermal analyses. The optimum thickness of tunnel-type bus-bar and the spacing and array among three bus-bars were calculated; and the surface temperature of tunnel-type bus-bar showed 7.9 °C lower than that of plate-type bus-bar in a 3-phase array condition. In addition, the surface and internal temperatures of the uncoated, CNT (Carbon nanotube)-coated, and BN (Boron nitride)-coated Cu bus-bars were measured with thermal imaging camera and the experiment using a hot plate. It was confirmed that the difference in the internal temperature between uncoated and BN-coated Cu was 19.4 °C. The application of the bus-bar improved from this study might contribute to the increase in power energy efficiency.

25 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
Saurabh YadavSaurabh Yadav
Saurabh Yadav
JLJIE LIU
JIE LIU
MKMansik Kong
Mansik Kong
YYYoung Gyoon Yoon
Young Gyoon Yoon
SKSung Chul Kim
Sung Chul Kim
In this study, experiments were performed to use the waste heat in a billet casting industry utilizing bismuth telluride thermoelectric generators (TEGs). Four d-type absorber plates made of copper were installed above the manufactured billet during the cooling process. Three sides of each absorber plate were attached to thermoelectric units. Therefore, a total of 12 units of the thermoelectric system were found to generate a power of 339 W. The power density of the TEG system was found to be 981 W/m2 while running the system at the operating voltage of the battery energy storage system (58 V). A one-dimensional numerical simulation was carried out using FloMASTERTM v9.1 (Mentor Graphics Corporation, Siemens, Dallas, TX, USA) to verify the experimental results, and the numerical results were found to exhibit good agreement with the experimental results. Furthermore, a one-dimensional numerical simulation was carried out to obtain the heat transfer characteristics at varying flow rates of cold water (Reynolds number = 2540–16,943) and at different inlet temperatures (10–25 °C) for the cold side of the TEG. The results indicate that the performance of the thermoelectric generator increases with an increase in the cold-water flow rate and a decrease in the inlet temperature of the cold water.

10 April 2024 in Archives of Metallurgy and Materials
Verified
Journal Article
Closed access
PDF file
WJWoo-Chul Jung
Woo-Chul Jung
HYHyunseok Yang
Hyunseok Yang
Seon-Jin ChoiSeon-Jin Choi
Seon-Jin Choi
MKMansik Kong
Mansik Kong
In the electropolishing process, the polishing quality of the metal surface varies according to the contamination of the electrolyte. In this study, the electrolyte was evaluated according to the usage time, and the effect of each factor on electropolishing was investigated. As the electrolyte is contaminated, the concentration of metal ions in the electrolyte increases and the ion conductivity decreases. In addition, the pH and specific gravity of the electrolyte increase due to the metal sludge formed as the metal ion concentration increases. When the electrolyte usage time was more than 5 days, many scratches remained on the surface of 316L stainless steel, and relatively high surface roughness was measured. The surface roughness improvement rate compared to the initial specimen was 30% for the unused electrolyte, 26% on the 3rd day, 19% on the 5th day, and 17.5% on the 13th day. Since the low current density due to electrolyte contamination causes a decrease in polishing efficiency, initial scratches on the metal surface still exist on the polished surface. Therefore, it is necessary to manage the electrolyte to maintain the quality of electropolishing.

29 November 2021 in Metal Science and Heat Treatment
Verified
Journal Article
Closed access
PDF file
HYHyunseok Yang
Hyunseok Yang
WJWoo-Chul Jung
Woo-Chul Jung
CLChanghee Lee
Changhee Lee
MKMansik Kong
Mansik Kong

28 December 2021 in Archives of Metallurgy and Materials
Verified
Journal Article
Closed access
HYHyunseok Yang
Hyunseok Yang
WJWoo-Chul Jung
Woo-Chul Jung
MKMansik Kong
Mansik Kong
CLChanghee Lee
Changhee Lee
Intermetallic γ-TiAl alloy has excellent properties at high temperatures and is thus attracting attention as a substitute for nickel-based superalloy parts for turbine engines. However, γ-TiAl alloy is reported to be a difficult material to be machined due to its low ductility at room temperature, tensile strength, and thermal conductivity. In this study, a system capable of measuring thrust force (Tf) and torque (Tc) during the drilling process was constructed, and drilling processability according to the heat treated microstructure of γ-TiAl alloy was compared. As a result, it was confirmed that the thrust and torque of the γ-TiAl alloy having a microstructure in which the grains were refined by the heat treatment process was relatively low and rapidly stabilized, which is advantageous for drilling.

27 October 2025 in Korean Journal of Materials Research
Verified
Journal Article
Open access
PDF file
DLDonhee Lee
Donhee Lee
DKDu Hong Kang
Du Hong Kang
PKPoongyeon Kim
Poongyeon Kim
DHDeokhyun Han
Deokhyun Han
MKMansik Kong
Mansik Kong
SCSi Young Chang
Si Young Chang
In this study, the surface characteristics-including roughness, oxide layer thickness, and composition-of the electropolished layer on STS316L steel tubes subjected to double melting via the VIM/VAR process were investigated after exposure to Cl 2 gas. The tubes were exposed to Cl 2 gas for 1 to 13 d to simulate semiconductor conditions. Surface roughness increased with Cl 2 exposure time, showing values of 0.01, 0.04, 0.04 and 0.03 µm after 0, 1, 5 and 9 d, respectively. At the same time, the oxide layer thickness on EPed STS316L, which was initially 8.2 nm, decreased to 3.18, 2.58 after 1, 5 d of Cl 2 exposure, approaching the initial thickness of 2.38 nm observed on non-EPed STS316L. After 9 d, the thickness further decreased to 0.51 nm, with no significant change was observed thereafter. Before Cl 2 exposure, the CrO/FeO ratio was 2.26. After 1, 5, and 9 d of exposure, the ratio decreased to 2.06, 1.75, and 1.27, respectively. In addition, the penetration depth of Cl into the oxide layer increased with longer exposure time. These results suggest that the formation of chromium chlorides led to the breakdown of the stable Cr 2 O 3 layer.