When collecting dust samples from coal-fired power plant chimneys, a nozzle specially designed with an inlet shape of circle type is used for constant velocity suction. However, it is cumbersome to use nozzles with different areas depending on the flow rate. In this study, the effect of the nozzle inlet shape of the isokinetic sampler on the performance of constant velocity suction was evaluated through simulation. The simulations were conducted using the realizable k−ε model, which is known to be suitable for separation flow analysis for particles of 1–50 μm. The turbulent flow fully developed before reaching the inlet of the sampling probe, and the flow rate was set under the condition that the uniformity was secured at approximately 92% at least. The aspiration ratio was employed for evaluating the degree of constant velocity aspiration of the isokinetic sampling probe. It was found that the larger the particle diameter and the faster the flow rate, the larger the aspiration ratio for both the circular and ellipsoidal inlets. In particular, compared with the circular inlet, the aspiration ratio of the sampler with ellipsoidal inlet was closer to 1 in the free-flow velocity range, from 5 to 15 m/s. For this reason, if the ellipsoidal inlet nozzle is used by adjusting only the length parallel to the major axis, the maintenance cost is expected to be reduced compared to the circle-type nozzle.
Recently, ammonium carbamate (AC) has attracted attention as a substitute for urea, which is a commonly used reductant for NOx emitted from combustion engines. The AC exists as a solid at room temperature, and it is decomposed to NH3 and CO2 gases by heating. Therefore, adequate heat transfer is an essential issue in the design of AC pyrolysis reactor. In this study, a numerical model that describes the sublimation of AC was developed. For modeling, this study considered the three different calculation zones: solid-phase zone, gas-phase zone, and sublimation zone. Additionally, during the sublimation process, collapse of upper solid AC into the hollow space below by the effect of gravity is considered. As a result, it is presented that the modeling shows reasonable information about the AC sublimation in a reactor, such as temperatures in a reactor, pressure of reactor, and flow rate of sublimated gas. However, it is also found that accurate prediction of spatial temperature distribution is challenging because it is related to the accurate prediction of the internal shape of AC and its collapse in a reactor.
To satisfy increasing demands for ecofriendly vehicles, researchers are now studying electric vehicle (EV)-related technologies. In particular, integrated bidirectional onboard battery charger (OBC)/low-voltage DC–DC converter (LDC) modules are being researched to improve the efficiency of onboard chargers for EV charging applications. In this study, a numerical analysis method is proposed that considers the power loss and heat flow characteristics in the design of a 7.2 kW integrated bidirectional OBC/LDC module. The developed module supports four operating modes depending on the service situation: OBC and LDC single operation, OBC/LDC simultaneous operation, and LDC operation. The mode is selected based on the power system flow. The characteristics of the circuit were analyzed in each of the four modes to compute the heat loss from the major heating elements. The results of a numerical analysis of the internal cooling characteristics showed that the internal temperature was higher in the OBC single operating mode than in the OBC and LDC simultaneous operating mode in which the power loss was the highest. The results emphasize the importance of ensuring that cooling designs consider the characteristics of various modes as well as the worst-case power loss.
Recent advancements in hydrogen tank technology have favored the use of composites over metals for weight reduction, although at the cost of a narrower operating temperature range. Therefore, this study aims to establish safety standards for charging tube skids—large tanks positioned vertically within hydrogen transport vehicles—by examining the variations in temperature distribution under different charging environments through numerical analysis. A two-dimensional axisymmetric model was developed based on ANSYS Fluent to incorporate the effect of buoyancy by applying gravitational conditions along the axial direction. The study analyzed the impact of various charging and environmental conditions (charging time (0~240 min), inlet temperature, ambient temperature, initial temperature (−20 °C~40 °C), and initial pressure (5~20 bar)) on temperature distribution, ultimately deriving a regression equation to predict the tank’s maximum temperature. The findings indicate that the initial temperature has the most significant correlation with the tank’s temperature, followed by charging time and ambient temperature. Inlet temperature and initial pressure demonstrated minimal influence within the study’s scope. The derivation of predictive formulas for the maximum temperatures of the tank’s three regions, all showing an R2 value of 0.99 or higher, highlights the practicality of these results. This study’s insights are expected to contribute to further research aimed at optimizing charging conditions for tube skids and other hydrogen tanks.
The onboard charger (OBC)/low-voltage DC-DC converter (LDC) integrated power inverter for electric vehicles comprises multiple electrical elements that can heat up, which can cause performance degradation and system instability issues in electric vehicles. To address this, a cooling system is included in the OBC/LDC integrated power inverter, which primarily uses water as a coolant. In this water cooling method, controlling the flow rate of water is critical for uniform cooling of the component. Thus, we propose an optimization method that helps determine the design variables to ensure uniform flow rate in each channel of the water-cooled system. The control variables for fluid-flux flow distribution optimization are selected by performing flow analysis for the initial design shape and analyzing their effects on fluid-flux flow distribution. For optimization analysis, the central composite design technique was applied; in addition, multi-response surface optimization using the same flow rate for each channel was performed. The optimization results were compared and verified using desirability functions based on the flow ratio of the cooling water channel, product function, and error function. Among single-response objective functions, the product function showed excellent performance. However, optimization using a multi-response objective function showed significantly higher prediction accuracy than the single-response function: using the optimized design obtained with the multi-response objective function improved the fluid-flux flow distribution uniformity by approximately 90% or more than the initial design.
During the recent decades, global warming by greenhouse gas evolution has attracted worldwide attention and ever increasing strict regulations thereon have become institutionalized as international policies. In the process, more environment-friendly power generation technologies have been developed utilizing fossil fuels with a view to timely commercialization. As one such “clean coal” technology, an Integrated Gasification Fuel Cell system is a promising power generation means where a carbonyl sulfide (COS) hydrolysis reactor is installed downstream of coal syngas to remove acidic gas constituents such as H2S and COS. The most significant design parameters affecting performance of the COS hydrolysis reactor were selected to be gas hourly space velocity (GHSV), reaction temperature, and length ratio, and numerical modeling was performed considering heat and fluid flow transfer as well as chemical reaction kinetics. Effect of the selected design parameters on the variation of conversion rate and reactant gas mixture concentration were comprehensively investigated to predict performance of the COS hydrolysis reactor. Stochastic modeling of reactor performance was finally performed using Monte Carlo simulation and linear regression fitting.